PR10560548 - Upgrade Kitchen at Oasis Club

Closed
19MU3022Q0007Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

General Info

Agency

Department Of State → Embassy Muscat

NAICS

2361 - Residential Building Construction

Place of Performance

DC

Set-Aside

NONE

Documents

2

Amendment+A00001.pdf

PDF

RFQ+19MU3022Q0007+Upgrade+kitchen+at+Oasis+Club.pdf

PDF

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

Solicitation

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of State → Embassy Muscat
Contacts2 people available
OfficeWASHINGTON, DC, 20520, USA
Organization / Agency
Department Of State → Embassy Muscat
Office AddressWASHINGTON, DC, 20520, USA
Contacts
Franchesca Minikon-Reece

Full Description

Show more
1)Demolish and dispose of the existing kitchen and a portion of the original servant quarters per drawing X8008 D-01. 2) Remove kitchen hoods (2 each) and set aside for reinstallation. 3) Demolish existing electrical panel and main electrical feed once the new feed has become operational. 4) Demolish and dispose of the existing fire alarm system. 5) Remove and store for reuse the following items: Automatic Transfer Switch 6) Existing roof demolition process should use slab cutting machine as the existing structure of the building cannot hold the vibration of the hammer breaker machine.

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS