Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

Pump Station Condition Assessment & PER Support

Active
State & Local

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

This subcontract involves providing technical evaluation services for existing wastewater infrastructure on projects for the Cape Fear Public Utility Authority. The scope of work focuses on conducting preliminary field investigations of a 46-year-old station and Model 30 MP Self Priming Hydromatic Pumps. The selected contractor will utilize condition assessment and pump performance testing equipment to gather and analyze technical data, which will ultimately support the development of a Preliminary Engineering Report. A Professional Engineer license is required to perform this work. The project falls under NAICS code 541330 and is structured as a subcontract for prime contractors. Interested parties should note the response deadline of November 5, 2026.

General Info

PE-led technical evaluation of wastewater infrastructure for Cape Fear Public Utility Authority.

Documents

This scope was carved out of 345-10/08/2026.

The full solicitation package (1 document), including the RFP, is on the prime solicitation, not on this scope.

View the prime solicitation

RFQ - Condition Evaluation for Replacement of Pump Station #33 Shamrock

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

Posted

subcontract

Response Deadline

Submission deadline

Response Deadline

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyNorth Carolina → Cape Fear Public Utility Authority
ContactsNo contacts available
OfficeN/A
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
Performs technical evaluation of existing wastewater infrastructure for prime contractors on Cape Fear Public Utility Authority projects. Conducts preliminary field investigations of a 46-year-old station and Self Priming Hydromatic Pumps (Model 30 MP) using condition assessment and pump performance testing equipment. Requires a Professional Engineer (PE) license. Delivers technical data and analysis for the Preliminary Engineering Report.

Similar Contracts

Same NAICS industry code

More opportunities from North Carolina → Cape Fear Public Utility Authority

Same awarding agency

NAICS: 541330
SLED
RFQ - Condition Evaluation for Replacement of Pump Station #33 Shamrock
Solicitation # 345-10/08/2026
The Cape Fear Public Utility Authority is seeking Statements of Qualifications from consulting engineering firms to perform a condition evaluation, design, and bidding assistance for the upgrade or replacement of Pump Station 33 Shamrock, located at 116 Kilarry Road in Wilmington, North Carolina. The project focuses on a 46-year-old station utilizing two Self Priming Hydromatic Pumps. The selected consultant will be responsible for delivering a Preliminary Engineering Report by February 18, 2027, completing the design by June 18, 2027, securing permits by August 2, 2027, and providing bidding assistance to reach a construction award by September 1, 2027. Key deliverables include detailed design plans, technical specifications, a sewer bypass plan, and necessary encroachment agreements. This solicitation follows a qualifications-based selection process in compliance with the Mini Brooks Act, where the contract will be awarded to the best qualified firm followed by the negotiation of a detailed scope of work and fee schedule. Proposals are evaluated on four equally weighted criteria: project understanding and approach, relevant firm experience, proposed staff experience, and a record of success, which must include five previous projects comparing cost estimates to low bids. To be eligible, firms must be registered with the Office of the Secretary of State and maintain specific insurance coverages, including 2 million dollars in professional liability and 1 million dollars in general and auto liability. Statements of Qualifications must be submitted in PDF format to bids@cfpua.org by 2:00 PM on November 5, 2026, and are limited to 20 pages, excluding resumes and appendices.
Engineering Services

POSTED

8 days ago

DEADLINE

in 20 days
View Details

Ready to Pursue This Opportunity?

Get AI-powered intelligence on this solicitation and the ones like it

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS