This Solicitation opportunity from Government of Canada was posted on March 20, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Quantum resistance calibration suite

Closed
25-58307International

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

AI Contract Overview

Show more

The National Research Council of Canada (NRC) is seeking the supply of two advanced resistance calibration suites designed to measure electrical resistance with an extremely high degree of precision, traceable to fundamental constants and achieving an uncertainty of 3 parts per billion or better. These integrated quantum resistance systems are crucial for supporting electrical standards, the realization of the kilogram, and scientific research in mass and electrical metrology. Each suite consists of a Quantum Hall Resistance (QHR) standard, a cryogenic current comparator (CCC), associated electronics, control software, and cryogenic systems that operate without the need for liquid helium. The first system will feature a compact, simplified design intended for integration with the existing NRC Kibble balance equipment, enabling mass traceability aligned with the kilogram definition and incorporating a QHR sample array with multiple calculable resistance values. The second system is tailored for low-temperature research and calibration applications, capable of accommodating a variety of QHR sample types with operation at temperatures as low as 1.3 K or below, maintaining high stability and a minimum magnetic field strength of 9 Tesla. Both systems will be outfitted with all necessary components to ensure full functionality of the QHR and CCC equipment. Responses to this solicitation are due by March 20, 2026, and the location of performance is Ontario, Canada.

General Info

Supply of two quantum resistance calibration suites for precision measurements and mass traceability, Ontario.

Agency

Government of Canada → National Research Council of CanadaView Agency

NAICS

334515 - Instrument Manufacturing for Measuring and Testing Electricity and Electrical SignalsView NAICS

Place of Performance

*Ontario (except NCR), CAN

Set-Aside

NONE

Documents

(2)

ACAN 25-58307 Quantum Resistance Calibration Suites

PDF6 pagesacan

ACAN 25-58307 Quantum Hall Resistance Calibration Suites

PDF7 pagesaward

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

PhaseClosed
Posted

Solicitation

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyGovernment of Canada → National Research Council of Canada
Contacts1 person available
OfficeN/A
Organization / Agency
Government of Canada → National Research Council of Canada
View Agency Profile
Office AddressN/A
Contacts
Grice El-HayekPoint of Contact

Full Description

Show more
The National Research Council of Canada (NRC) has a requirement for the supply of two resistance calibration suites able to allow measurement of resistance traceably to fundamental constants with an uncertainty of 3 parts per billion [ppb], or better. This is in support of the realization of the kilogram, electrical standards and research. The combined and integrated quantum resistance suite is a critical tool for electrical and mass metrology allowing measurement and calibration of resistance down to a level of 3 ppb or better, across a range of resistance values. It is an integrated system comprised of a Quantum Hall Resistance (QHR) standard and a cryogenic current comparator (CCC), with associated electronics, and cryogenic systems that allow system operation without need for liquid helium supply. Each system must include a QHR standard system and a CCC supplied as an integrated unit with supporting electronics and control software. The first system (A) will be a simplified, compact system of small footprint that will be integrated to the existing NRC Kibble balance equipment and will enable mass traceability to the definition of the kilogram. This system shall be provided with a QHR sample array with multiple resistance values that can be calculated directly from fundamental constants. The second system (B) shall be provided for low temperature research and calibration, able to accommodate a broad set of QHR sample types and therefore able to reach 1.3 K or lower with high stability and with a minimum magnetic field strength of 9 Tesla. All systems shall be provided with all the necessary appurtenances needed to operate the QHR and the CCC equipment.

More opportunities from Government of Canada → National Research Council of Canada

Same awarding agency

NAICS: 334513
New
International
High Capacity Load Cell
Solicitation # 26-58130
The National Research Council Canada is soliciting offers for the acquisition of a high-capacity, low-profile tension and compression load cell to be used in a structures laboratory for large-scale testing of components, assemblies, and materials. The required equipment must be a ready-to-integrate solution that is mechanically, electrically, and functionally compatible with an existing MTS 201.90 servo-hydraulic actuator. Key technical specifications include a maximum height of 10.5 inches and hub/base threads of 4-8 UN 3B with a minimum depth of 4.25 inches. The load cell must be supplied with a base, screws, a lifting plug, connector protectors, and a minimum 5-point tension and compression calibration for each of the two required bridges. This open solicitation is subject to the Policy on Reciprocal Procurement, limiting eligibility to Canadian suppliers. The contract will be awarded to the compliant offer with the lowest evaluated price, provided all mandatory technical criteria are met. All deliverables must be received at the National Research Council Canada in Ottawa, Ontario, by December 1, 2026, with a required delivery lead time of 13 weeks from the date of contract award. The contract period extends until December 31, 2026. Offers must be submitted electronically, separated into technical and financial sections, by the closing date of September 28, 2026.
Instruments and Related Products Manufacturing for Measuring, Displaying, and Controlling Industrial Process Variables

POSTED

2 days ago

DEADLINE

in 19 days
View Details
NAICS: 334516
New
International
Liquid Dispensing Robot for High Throughput Experimentation
Solicitation # 26-58029
The National Research Council Canada is soliciting proposals for a fully automated liquid-dispensing robot to be integrated into a material acceleration platform at the NRC Mississauga facility. The required system must be designed for high-throughput and complex workflows, featuring a modular architecture with interchangeable pipettes, grippers, and on-deck modules for heating and stirring. Key technical mandates include the use of 8-channel or higher pipettes with a capacity of 1-1000 µL or greater, an open protocol library, and open-source software API for configuration and integration. The hardware must support dual-band Wi-Fi, USB 2.0, and Ethernet connectivity. The procurement process is an open Request for Proposal with a closing date of September 22, 2026. Evaluation is based on mandatory technical criteria and a financial assessment of the total aggregated cost for the robot, installation, and training. Successful delivery is required within 16 weeks of the contract award, following Delivery at Place (DAP) terms. The contract emphasizes green procurement, requiring reusable, returnable, or recyclable packaging. Bidders must submit their proposals via email in three distinct sections covering technical, financial, and administrative requirements, ensuring compliance with Canadian electrical standards and security clearance protocols.
Analytical Laboratory Instrument Manufacturing

POSTED

6 days ago

DEADLINE

in 13 days
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 650+ contractors already using CLEATUS