Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, December 9 at 2:00 PM ET

Register Free →

This Solicitation opportunity from General Services Administration was posted on November 26, 2021. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Relative Accuracy Test Audit - RATA

Awarded
47PM1122Q0003Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

General Info

Contract Value

$49,360

NAICS

54162

Place of Performance

Washington, DC, 20407, USA

Set-Aside

SBA

Award Issued Date

Documents

1
PDF

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseAwarded
Posted

Solicitation

Awarded

Contract was awarded

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyGeneral Services Administration → Pbs R11 Building Services Division Center 2
Contacts1 person available
OfficeWASHINGTON, DC, 20405, USA

Full Description

Show more
The boilers (Boiler Nos.1, 2, 3, 4, 5, & 6) proposed are served by ESC-installed Continuous Emissions Monitoring Systems (CEMS) at GSA Central Heating and Refrigeration Plant (CHRP). All boilers at the GSA Central Heating and Refrigeration Plant are equipped to combust natural gas and No. 2 grade ultralow-sulfur fuel oil. Boiler Nos.1, 2, and 6 are rated at 250mmBTU/HR. Boiler No.5 is rated at 326mmBTU/HR and boiler Nos.3 and 4 are rated at 500mmBTU/HR. GSA Central Heating and Refrigeration Plant is a major source and must comply with the New Source Performance Standards (NSPS). The CEMS monitors opacity, NOx, CO, and 02 as diluent gas. All RATA shall be performed in accordance with EPA 40 CFR Part 60 and Part 75. At the CHRP, Boilers 1, 2, & 6 maybe Part 60. Boilers 3, 4, & 5 must be Part 75. The contractor shall furnish all the necessary labor, equipment, and supervision to perform Relative Accuracy Test Audits (RATA) as specified in Code of Federal Regulations,Title 40 Part 60 and Part 75 for NOx, CO, and 02 at the Central Heating and Refrigeration Plant located at 325 13th Street, SW, Washington, DC, 20407. This contract is for a base year with four one year, option years.

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS