Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Combined Synopsis/Solicitation opportunity was posted on July 31, 2015. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Renovation of Animal Rooms,Jefferson Laboratories, Building 5A

Closed
15-223-SOL-0056Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 236210
New
Federal
Building 215 Clean Room HEPA Filter Replacement
Solicitation # RFI-195000-26-00181
The National Institute of Standards and Technology is conducting market research through a Request for Information for the Building 215 Advanced Measurement Laboratory cleanroom repair and HEPA filter replacement project in Gaithersburg, Maryland. This initiative follows a previous solicitation that failed to produce an acceptable offer, prompting NIST to reassess its acquisition strategy and seek industry feedback on constructability, cost, and schedule feasibility. The project scope involves the modernization of an 1,800 square meter facility, including the replacement of approximately 1,200 HEPA filters, 70 VAV terminal units, and 54 airflow monitoring devices, as well as the installation of 32 exhaust air control valves and associated ductwork repairs, testing, and recertification. A critical component of the project is the proposed phasing plan, which aims to minimize research disruptions by utilizing 19 construction phases, including 18 critical cleanroom outage phases. Each critical outage is currently envisioned as a nine-day window starting Friday evening and requiring 24/7 operations to achieve ready-for-re-occupancy by the following Monday morning. NIST is specifically requesting rough-order-of-magnitude cost estimates and industry input on whether this aggressive outage schedule is realistic or if it creates prohibitive risks and costs. Responses, including company experience and recommendations for improving competition and project execution, are due by October 14, 2026.
Department Of Commerce Nist

POSTED

2 days ago

DEADLINE

in 12 days
NAICS: 236210
New
Federal
Sources Sought - POST TEST LITHIUM BATTERY STORAGE
Solicitation # N00167-27-RFPREQ-CD-102-0002
The Naval Sea Systems Command Naval Surface Warfare Center Carderock Division is conducting a sources sought effort for the construction of a Post-Test Lithium Battery Storage Facility in West Bethesda, Maryland. This project, classified under NAICS code 236210 for Industrial Building Construction, involves the creation of a storage area featuring a non-flammable single-pitch sloped roof, a perimeter fence with a gate, 3-hour rated firewalls, and concrete walls for large battery storage. Additional requirements include low-voltage outlets, pole-mounted LED flood lighting, and a dedicated forklift access road. The effort must be completed within 210 days of the award and adhere to Unified Facilities Guide Specifications and other stringent technical criteria. This notice is not a request for proposal, and no award will be made directly from this notice. Interested small and large businesses must submit a capability statement and a Rough Order of Magnitude by 1700 EST on 18 November 2026 to Heather Valiga. The government will use these responses to determine the future acquisition strategy. Because the project is located on a secure military installation, all personnel must obtain proper clearances and credentials. Key deliverables include an Activity Hazard Analysis and a detailed schedule due within five days of the pre-construction meeting, as well as a personnel list provided seven days before the start date.
Nswc Carderock

POSTED

2 days ago

DEADLINE

in 28 days

AI Contract Overview

Show more

Solicitation 15-223-SOL-0056 concerns the renovation of animal rooms in Building 5A at Jefferson Laboratories, located in Jefferson, Arkansas. This project falls under NAICS code 236210 and involves comprehensive facility upgrades, including the renovation of animal rooms and equipment platforms. The scope of work is supported by detailed specifications and drawings covering general renovations and fire alarm and detection systems. Key administrative requirements include the mandatory provision of performance and payment bonds, which must be submitted within ten calendar days following the contract award. Prospective contractors are required to complete security card access requests and commit to protecting non-public information. The solicitation process includes a pre-proposal conference and site visit, with past performance evaluations used as part of the selection criteria.

General Info

Agency

N/A

Contract Value

$3,258,390.64

NAICS

236210 - Industrial Building Construction

Place of Performance

US Food and Drug Administration National Center for Toxicological Research 3900 NCTR Road, JEFFERSON, AR, 72079, USA

Set-Aside

SBA

Awardee

NOACON INC

Award Issued Date

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

2 updates
PhaseClosed
Posted

Combined Synopsis

Notice updated

Response deadline changed from Jul 29, 2015 to Aug 3, 2015. The notice description changed.

Notice updated

The notice description changed.

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyN/A
Contacts1 person available
OfficeN/A
Organization / Agency
N/A
Office AddressN/A
Contacts
Sondea R BlairContract Specialist

Full Description

Show more
Amendment 0002 Solicitation 15-223-SOL-0056 Performance and payment bonds are required per Section G-5 and Section F-1 of the solicitation. Box 12a of the 1442 should be checked "yes". Box 12b should state "within ten (10) calendar days after date of contract award". See attached: Amendment 0001 of Solicitation 15-223-SOL-0056 Attachment I Pre-proposal Conference Site Visit Information Attachment J-2 Drawings: S.1. Building 5A - Renovation of Animal Rooms, Equipment Platform Existing Framing Demo Plan dated July 6, 2012, (1) page. S.2 Equipment Platform New Framing Plan, dated July 6, 2012, (1) page. Attachment J-8 Clarification Support Documentation (4) pages: See attached files: Solicitation 15-223-SOL-00056 J-1 Specifications - Renovation of Animal Rooms, Building 5A, Jefferson Laboratories J-2 Drawings -Renovation of Animal Rooms J-3 Fire Alarm and Detection Systems Technical Specifications J-4 Drawings - Fire Alarm System J-5 FDA Form 3391, Security Card Access Request J-6 FDA Form 3398, Contractor Commitment to Protect Non-Public Information J-7 Past Performance Evaluation Questionnaire

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS