26-138 Main grounding electrode conductor is not provided
Solicitation # 26-138
Solicitation 26-138 is a request for a licensed electrical contractor to inspect and correct grounding system deficiencies at the Atterbury Job Corps Center in Edinburgh, Indiana. The primary scope of work involves establishing an effective ground-fault current return path by connecting main grounding electrode conductors from incoming water pipes to service distribution panels. Specific requirements include installing a new #4AWG conductor from the water main to the 200A service panelboard in the Staff Lounge, providing two supplemental 5/8 inch by 8 foot grounding electrodes connected via #6AWG bare copper conductor, and ensuring all work conforms to NEC 2020, 250, as well as current EPA and OSHA regulations. The contract is a small business set-aside and will be awarded based on best value, with evaluation weights assigned to price (60 points), quality (20 points), past performance (10 points), and schedule (10 points). Bidders must submit a single lump sum proposal including a detailed cost breakdown, a timeline for substantial completion, a 90-day bid guarantee, and certification of compliance with Davis Bacon Act wage rates. Mandatory requirements for submission include a valid Indiana Contractor's License, a completed W9, and attendance at the mandatory pre-bid site visit. The contractor must also provide proof of automobile liability and workers compensation insurance, naming Adams and Associates, Inc. as an additional insured. Payment terms are set at Net 30.
Atterbury Job Corps. – Adams & Associates

POSTED

about 2 hours ago

DEADLINE

in 22 days
NAICS: 238210
New
Transformer Oil Testing Services
Solicitation # RFP-VC-26-010
The Inland Empire Utilities Agency is soliciting proposals under RFP-VC-26-010 for professional transformer oil testing services to enhance the reliability, safety, and maintainability of its transformers. The scope of work is divided into three primary areas: conducting visual and infrared thermographic inspections on energized transformers to identify thermal anomalies, installing standardized external oil sampling devices for safer collection, and performing detailed oil testing analysis. Additionally, the selected contractor must evaluate existing nitrogen blanket systems to ensure positive pressure and provide on-site training for up to 20 agency staff members on inspection methods and defect identification. All work must adhere to strict industry standards, including NETA MTS, IEEE, NFPA 70E, and ASTM D923, with infrared inspections performed by ASNT Level 1 certified technicians or higher. The agency intends to make a single award to the most capable offeror based on their past performance, staffing plan, personnel availability, and cost-effectiveness. Qualified proposers must have completed at least two similar projects within the last five years, including at least one for a utility or industrial facility. Proposals must be submitted electronically via PlanetBids by December 23, 2026, and must include a detailed project approach, company profile, and required certifications such as a Non-Collusion Statement and Workers Compensation Certificate. The resulting contract will utilize fixed pricing with a not-to-exceed limit, and payments will be processed electronically via ACH within 30 days of invoice approval by the Project Manager.
Inland Empire Utilities Agency

POSTED

about 2 hours ago

DEADLINE

in about 2 months
NAICS: 238210
New
Centennial JCC Emergency Lighting Replacement, Upgrade, Testing & Maintenance Services
Solicitation # centennial-jcc-emergency-lighting-replacement-upgrade-testing-maintenance-services
Management and Training Corporation is soliciting bids for a fixed-price, single lump sum contract to provide emergency lighting replacement, upgrade, testing, and maintenance services at the Centennial Job Corps Center in Nampa, Idaho. The project involves the inspection, testing, repair, and certification of emergency lighting systems to ensure compliance with NFPA 101 (2024 Edition) and NFPA 70 standards. The selected electrical contractor will be responsible for inventorying all fixtures, performing functional power-cut tests, applying durable tracking labels, and integrating recurring maintenance into the facility's Computerized Maintenance Management System. The estimated contract value ranges from $25,000 to $100,000, with a performance period of 30 business days following the written Notice to Proceed. Bids are due by December 1, 2026, and must be submitted via email to Sandra Clore. A mandatory physical site visit and signature on the attendance roster are required prior to bid submission. For bids equal to or greater than $25,000, contractors must provide a bid bond guarantee of 20% of the base bid, as well as performance and payment bonds from a surety company with at least an A- rating. The award will be based on overall best value. This opportunity is set aside for small businesses, including VOSB, SDVOSB, WOSB, and HUBZone certified entities. The contract mandates strict adherence to federal labor and safety regulations, including the Davis-Bacon Act, Service Contract Labor Standards, and Executive Order 14026 regarding minimum wages. Contractors must provide paid sick leave per EO 13706 and display required bilingual employee rights and wage determination notices. Compliance with various FAR clauses is required, including those regarding the Buy American Act, whistleblower rights, and the prevention of trafficking in persons. Final acceptance and payment are contingent upon a substantial completion inspection and the resolution of a final punch list.
Management & Training Corporation/Centennial Job Corps Center

POSTED

about 2 hours ago

DEADLINE

in about 1 month

AI Contract Overview

Show more

Solicitation W50S8426BA002 is a total small business set-aside for the Department of Defense, specifically the Michigan Air National Guard, to perform electrical repairs in building 6930 at Battle Creek ANGB, MI. The scope of work requires the complete replacement of two Main Distribution Panels and associated switchgear, including the de-energizing, removal, and disposal of existing equipment and the installation, testing, and commissioning of new 480/277 V and 120/208 V panels. The contractor must ensure that the Automatic Transfer Switch and generator circuits remain fully operational and is required to provide a site superintendent during all work. The period of performance is 365 days from the issuance of the Notice to Proceed, including a winter exclusion. Key requirements include a one-year warranty from the date of final acceptance, the submission of all closeout documents, and full site restoration. Bids must be submitted electronically through the PIEE Solicitation module by August 27, 2026, at 14:00. Payment bonds are required for all projects, and performance bonds are required if the contract price exceeds 150,000 dollars. While the projects are currently unfunded, the government anticipates funds will be available by September 30, 2026.

General Info

Replace two electrical panels and switchgear at Battle Creek Air National Guard Base with full compliance and uninterrupted generator circuit functionality.

NAICS

238210 - Electrical Contractors and Other Wiring Installation Contractors

Place of Performance

Battle Creek ANGB, MI, MI, 49037

Set-Aside

SBA

Documents

3

Pre-Bid Site Visit Minutes for Battle Creek ANGB Solicitations W50S84-25-B-A001 to A004

PDF, High priority: read this first4 pages · site-visit-minutes
High

Q&A - B6930 Breakers

PDF, Low priorityq-and-a
Low

W05058426-B-AD02 Bid Opening Abstract

PDF, Low prioritybid-opening-abstract
Low

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

3 updates
PhaseClosed
Posted

Solicitation

Notice updated

The notice description changed.

Notice updated

The notice description changed.

Notice updated

The notice description changed.

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → W7NF Uspfo Activity Miang 110
Contacts1 person available
OfficeBATTLE CREEK, MI, 49015-5515, USA
Office AddressBATTLE CREEK, MI, 49015-5515, USA

Full Description

Show more

UPDATE 27 Aug 2026: This update is to post the 27 Aug 2026 Bid Abstract results. These are initial results only pending review for bid mistakes and verification of bid responsiveness. No award will be made until all solicitation requirements are confirmed.


UPDATE 20 AUG 2026: Responses to RFIs posted. See Questions and Answers in attachments.


UPDATE 13 AUG 2026: Posted site visit minutes and attendance sheet. Solicitation is not amended and response date has not changed.


The work shall be in strict compliance with this SOW, the project specifications, and the project drawings. The Contractor shall provide all personnel, equipment, tools, materials, supervision, and quality control necessary for the complete replacement of two (2) Main Distribution Panels (MDPs) and their associated switchgear in building 6930. Work includes de-energizing, removing, and disposing of existing equipment, as well as installing, reconnecting, testing, and commissioning the new 480/277 V and 120/208 V panels, ensuring the Automatic Transfer Switch (ATS) and generator circuits remain fully operational in accordance with this Statement of Work (SOW). The contractor shall perform to the standards outlined in the contract. REMINDER: Acknowledge all amendments in your Bid Package. SITE VISIT: A site visit for this project is scheduled for the date and time stated in the solicitation. Access to Battle Creek ANGB is through the Main Entrance at 1701 Hill Brady Rd, Battle Creek, MI 49037. Attendees will be escorted from the Main Entrance to the site visit location. See solicitation for details.SITE VISIT: A site visit for this project is scheduled for the date and time stated in the solicitation. Access to Battle Creek ANGB is through the Main Entrance at 1701 Hill Brady Rd, Battle Creek, MI 49037. Attendees will be escorted from the Main Entrance to the site visit location. See solicitation for details.

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS