Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, September 16 at 2:00 PM EDT

Register Free →

This Solicitation opportunity from Department Of Defense was posted on August 6, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Repair Chilled Water Lines - Amendment 0002

Closed
W519TC26QA162Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 237110
New
Seeking MBE/DBE/WBE Subcontractors and Suppliers for South Marsham Street Green Infrastructure Project (Romney, WV)
Solicitation # seeking-mbedbewbe-subcontractors-suppliers-south-marsham-street-green-infrastructure-project-romney
Harbel, Inc. is seeking MBE, DBE, and WBE subcontractors and suppliers for a targeted green-street retrofit project in downtown Romney, West Virginia. The project involves the construction of approximately 343.59 linear feet of South Marsham Street between Gravel Lane and US Route 50. The scope of work includes the installation of 1,450 square feet of permeable pavement, eight vegetated stormwater management cells, and necessary drainage, underdrain, inlet, pipe, tie-in, and downspout work. Additionally, the project requires limited curb, sidewalk, ADA, apron, crossing, and traffic-calming improvements to integrate the BMP corridor, as well as the planting of six native trees and approximately 345 native plants. The goal is to treat approximately 1.7 acres of impervious surface within a 3.3-acre drainage area, concluding with final stabilization, cleanup, and restoration. This solicitation is open to various small business concerns, including veteran-owned, service-disabled veteran-owned, HUBZone, disadvantaged, woman-owned, and minority-owned businesses. To accommodate the project scale, these entities are encouraged to form consortiums if individual bid items are too large for a single firm to handle. Bids must be submitted by September 17, 2026, at 4:00 P.M. Interested parties should contact Jonah Leith or Jennifer Wilson for further details and must provide a response indicating their intent to bid.
Harbel, Inc.

POSTED

about 11 hours ago

DEADLINE

in 4 days
NAICS: 237110
New
Inland Feeder/SBVMWD Foothill PS Intertie, Stage 1
Solicitation # inland-feedersbvmwd-foothill-ps-intertie-stage-1
The Inland Feeder/SBVMWD Foothill PS Intertie, Stage 1 project, located in Highland, California, is a comprehensive infrastructure initiative issued by the Metropolitan Water District of Southern California through James W. Fowler Co. The scope of work involves the furnishing and installation of approximately 2,150 linear feet of 54-inch to 66-inch diameter steel pipe and 200 linear feet of 144-inch diameter steel pipe. The project includes the installation of both contractor-furnished and Metropolitan-furnished valves ranging from 54 to 132 inches in diameter, as well as 54-inch and 145.5-inch diameter tie-ins and associated pipe fittings. Additional construction requirements include the delivery of four surge tanks, two valve vaults, an air compressor yard structure, and various drainage improvements. The technical scope extends to electrical upgrades, instrumentation and controls, piping systems, welding, disinfection, and surface restoration, alongside the excavation of cobbles and large boulders. This solicitation, posted on September 11, 2026, with a response deadline of September 29, 2026, is open to small businesses, including certified service-disabled veteran-owned, minority, and women-owned enterprises. The prime contractor, J.W. Fowler, is actively seeking subcontractor pricing and offering support to M/W/DBE firms regarding bonding, insurance, and equipment procurement to maximize participation.
James W. Fowler Co.

POSTED

about 11 hours ago

DEADLINE

in 16 days

AI Contract Overview

Show more

The U.S. Army Contracting Command – Rock Island is soliciting bids for the repair and replacement of chilled water piping between Building 108 and Building 114 at the U.S. Army Garrison in Rock Island, Illinois, under solicitation number W519TC26QA162. The project requires the installation of two new 10-inch dual-wall preinsulated PVC chilled water lines running in an open trench through parking lot 131A, 2nd Street, parking lot 144, and South Avenue, along with connecting the lines inside both buildings. The scope includes disconnecting existing piping, cutting and patching floors, excavating and backfilling with six inches of man sand beneath the pipes and one foot above, replacing and restriping disturbed pavements, and installing new flowmeters in the chilled water return lines. All work must comply with the 2026 Statewide Urban Design and Specifications (SUDAS), the FHWA MUTCD for traffic control, and other specified standards. The contract is structured as a lump sum fixed-price project with a total small business set-aside under NAICS code 237110, requiring performance and payment bonds. The contractor must submit a preliminary project schedule and a detailed construction schedule, with work required to begin within 45 working days of the notice to proceed and be fully completed, including closeout documentation and site cleanup, within 150 working days. The contractor must maintain a quality control system compliant with FAR 52.246-12 and adhere to rigorous inspection protocols, including a pre-final inspection, punch list resolution, and a final acceptance inspection attended by the contractor’s QC manager, project superintendent, and government representatives with at least 14 days’ advance notice. The contractor must provide a qualified project superintendent with at least 10 years of construction experience, including five years managing similar complexity projects, and a full contractor quality control organization including a Site Safety and Health Officer (SSHO) trained and certified under EM 385-1-1 (2024), a QC manager, and sufficient personnel to ensure safety and compliance. The SSHO must report directly to a senior official independent of the QC manager and be formally designated on ENG Form 6282. All materials must meet strict packaging and labeling requirements: piping must be sealed at both ends, insulation must be asbestos-free, and all adhesives, coatings, and insulation

General Info

Repair chilled water lines between Buildings 108 and 114, small business set-aside, bonds required, deadline June 29, 2026.

Agency

Department Of Defense → W6QK Acc-RiView Agency

NAICS

237110 - Water and Sewer Line and Related Structures ConstructionView NAICS

Place of Performance

Rock Island, IL, USA

Set-Aside

NONE

Documents

(18)

SOW 2025-0316 Repair Chilled Water Lines Bldg 108 to 114

PDFsow

Appendix B - 2025-0316 Repair Chilled Water Lines - Specifications

PDFspecifications

Specifications for Repair of Chilled Water Lines 2025-0316

PDFspecifications

Attachment+0007_Chiller+Building+Pic+2.jpg

JPG

Amendment 0002 to Solicitation W519TC26QA162

PDFamendment

Solicitation W519TC26QA162 Repair Chilled Water Lines

PDFrfq

Submittal Register for Contract 2025-0316 Repair Chilled Water Lines

PDFsubmittal-register

Attachment+0008_Chiller+Building+Pic+3.jpg

JPG

Attachment+0006_Chiller+Building+Pic+1.jpg

JPG

2025-0316 Repair Chilled Water Lines Plans - Rock Island Arsenal

PDFplans

2025-0316 Repair Chilled Water Lines Submittal Register

PDFsubmittal-register

Repair Chilled Water System Building 114 Drawings

PDFspecifications

Repair Chilled Water Lines Bldg 108 to 114 Project 2025-0316 Plans

PDFplans

Attachment+0009_Attendee+List.jpg

JPG

Amendment 0001 to Solicitation W519TC26QA162

PDFamendment

Solicitation W519TC26QA162 Repair Chilled Water Lines

PDFrfq

SOW 2025-0316 Repair Chilled Water Lines Bldg 108 to 114

PDFsow

Repair Chilled Water System Building 114 Drawing

PDFother

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

3 updates
PhaseClosed
Posted

Presolicitation

Amendment 1

Contract was updated

Type Changed

Presolicitation → Solicitation

Amendment 2

Contract was updated

Amendment 3

Contract was updated

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → W6QK Acc-Ri
Contacts2 people available
OfficeROCK ISLAND, IL, 61299-0000, USA
Organization / Agency
Department Of Defense → W6QK Acc-Ri
View Agency Profile
Office AddressROCK ISLAND, IL, 61299-0000, USA
Contacts

Full Description

Show more

The Army Contracting Command - Rock Island (ACC-RI) requests a quote for the US Army Garrison to repair the chilled water pipes from building 108 to building 114. See attachments for details, Amendment 0001. 

More opportunities from Department Of Defense → W6QK Acc-Ri

Same awarding agency

NAICS: 237110
New
Federal
Install Utilities - RV Campground Site - Rock Island Arsenal (Amendment 0003)
Solicitation # W519TC-26-R-A072
The Army Contracting Command - Rock Island is soliciting proposals for a commercial firm-fixed-price construction contract to install utilities for a new RV campground site at the Rock Island Arsenal in Illinois. This 100% small business set-aside project involves the installation of an 8-inch HDPE water main with a fire hydrant, a 1-inch gas main with a meter, and a 13.8 KV overhead electrical service leading to a 750 KVA transformer. The work must adhere to the 2026 Iowa State Urban Design and Specifications Program (SUDAS) and USACE EM 385-1-1 (2024) safety standards. The contractor is required to complete the project within 180 working days from the Notice to Proceed, with liquidated damages set at 1,000 dollars per calendar day of delay. Proposals are due by September 15, 2026, and must include a total firm-fixed-price bid, a high-level project schedule, resumes for a Quality Control Manager and Site Safety and Health Officer, and evidence of past performance on similar utility projects. The government will award the contract based on the best overall value, conducting a comparative analysis of price, schedule, personnel, and past performance. Required responsibility documents include a bid bond of 20 percent of the bid price or 3 million dollars, whichever is less, and proof of current contractor licensing. Payment will be processed electronically through the Wide Area WorkFlow system.
Water and Sewer Line and Related Structures Construction

POSTED

1 day ago

DEADLINE

in 3 days
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 650+ contractors already using CLEATUS