This Solicitation opportunity from Department Of The Air Force was posted on May 29, 2025. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Repair Transformers Upgrade Lighting Okuma

Awarded
FA527025R0010Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

AI Contract Overview

Show more

The contract involves comprehensive electrical system upgrades at Okuma, focusing on the removal and replacement of existing TH-6 and TH-7 transformers and associated area lighting. The scope includes demolishing old transformer house buildings and replacing pole-mounted transformers with new concrete pad-mounted units, complete with footings, mountings, and decorative enclosures. Wiring will be rerouted as necessary to connect the new transformers, which will be equipped with secondary main distribution panels and lighting control panels within the transformer enclosures. All existing transformers, which are contaminated with PCBs, must be safely abated and disposed of in accordance with applicable government and federal regulations. The project emphasizes sustainable practices, incorporating life cycle cost-effective principles, and must adhere to DoD, Air Force, and base design standards. The design was 0% complete as of July 20, 2023, and the work aims to deliver a fully functional and safe electrical facility, with laydown areas to be determined. The solicitation for this project, titled "Repair Transformers Upgrade Lighting Okuma," was posted on May 29, 2025, with a response deadline of June 5, 2025. It is managed by the Department of the Air Force under NAICS code 334416, and the contract is open for responses from qualified organizations. The primary points of contact are Leona Cantu and Rosita Crawford, who can be reached via email or phone for further information. The project site is located within the APO area, with performance expected in the ZIP code 96863, and detailed project information is available through the provided online link.

General Info

Electrical system upgrades at Okuma transformer houses #6 and #7 with PCB disposal, new transformers, lighting.

Agency

Department Of The Air Force → FA5270 18 Cons Pk

NAICS

334416 - Capacitor, Resistor, Coil, Transformer, and Other Inductor Manufacturing

Place of Performance

B116 North Beach Road Okuma, Kunigami, Kunigami District,Okinawa Prefecture 905-1412 Japan, 96863

Set-Aside

NONE

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseAwarded
Posted

Solicitation

Awarded

Contract was awarded

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of The Air Force → FA5270 18 Cons Pk
Contacts2 people available
OfficeAPO, AP, 96368-5199, USA
Organization / Agency
Department Of The Air Force → FA5270 18 Cons Pk
Office AddressAPO, AP, 96368-5199, USA

Full Description

Show more
Work will include, but not limited to, removal and replacement of the existing TH-6 and TH-7 electrical system and area lighting at Okuma. Demolish the old transformer house buildings #6 and #7. Replace the existing pole mounted transformers inside of TH-6 and TH-7 with US type outdoor transformer units. New transformers will be concrete pad mounted with footings, mountings, and decorative wall enclosure. Wiring will be rerouted as required to connect power to new transformers. Demolition and dispose of existing transformers, exteriorenclosures, concrete and wooden poles, and lighting include all conduits, conductors, and controls. New transformers will be equipped with new secondary main distribution panels that will include lighting control panels in transformer enclosure. The new outdoor transformer units will sit on new concrete pads with additional handholes. All existing transformers are contaminated with Polychlorinated Biphenyls (PCBs) therefore abatement and disposal of toxic materials must comply with all Government of Japan and Federal rules and regulations. Provide all work and appurtenances for a complete and usable facility. Laydown areas to be determined. This project will comply with applicable DoD, Air Force and base design standards. Sustainable principles, to include life cycle cost-effective practices, will be integrated into the design, development, and construction of the project in accordance with UFC 1-200-02. Project design is 0% complete as of 20 Jul 2023

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown