Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, December 9 at 2:00 PM ET

Register Free →

Request for Expression of Interest - Accountability and Entry Control Board System

Open
International
Response DeadlineDue in 15 days
Solicitation #
EI26-317

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

General Info

NAICS

N/A

Place of Performance

CAN

Set-Aside

NONE

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Ask CLEATUS

I've read this contract. Ask me anything.

Timeline

PhaseSources Sought
Posted

Sources Sought

Response Deadline

Submission deadline

Ready to pursue this opportunity?

Get full access to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyMunicipality of Chatham-Kent
ContactsNo contacts available
OfficeCAN
Organization / AgencyMunicipality of Chatham-Kent
Office AddressCAN
ContactsNo contact information available

Full Description

Show more
Chatham-Kent Fire & Rescue is seeking information on accountability and entry control board systems for use at emergency incidents. This RFEI will help Chatham-Kent Fire & Rescue understand what is available in the market, how well each option meets its operational needs, and what it would take to deploy it across its stations and apparatus.Operational Need. Knowing who is on scene, where they are, what they are doing, and when they went in is the foundation of fireground safety. Incident Commanders and Accountability Officers need a board that does this consistently, under stress, in poor conditions, and with minimal setup time. The operating context includes:19 fire stations serving urban, rural and agricultural response areas across approximately 2,500 km².A composite staffing model of career and volunteer firefighters, with responders arriving at different times and from different stations.Mutual aid and multi-agency incidents where crews from other departments need to be tracked on the board.Incidents with a single Incident Commander and no dedicated Accountability Officer in the first minutes.Year-round use in rain, snow, heat, darkness and smoke, often by personnel wearing gloves.Scope of Information Requested. Chatham-Kent is interested in physical, digital and hybrid solutions. Vendors may propose one or more of the following: Portable physical boards with tags, magnets, dry-erase or similar components.Tablet or software-based accountability and entry control systems.Hybrid systems that combine a physical board with a digital record.Accessories such as tags, vehicle-mounted tag holders, carry cases, timers and command worksheets. Critical Fireground Functions. The solution must support the fifteen functions (F1 to F15) set out in Appendix A: Personnel Accountability; Entry Control; Crew Integrity; Air Management; Elapsed Time and Benchmarks; Personnel Accountability Report (PAR); Assignment and Division / Group Tracking; Rapid Intervention Team (RIT) Readiness; Mayday and Evacuation Support; Staging and Resource Status; Rehabilitation Tracking; Radio and Tactical Channel Tracking; Hazard and Zone Awareness; Incident Command Integration; and Incident Record For each one, Vendors should state whether the product meets the requirement fully, partially or not at all, and describe how. Appendix A provides the checklist for this response. These requirements are informed by NFPA 1561, NFPA 1550 and the Ontario Section 21 Firefighter Guidance Notes, including Note 5-1: Firefighter accountability and entry control.Deployment and Usability Requirements. A board that is hard to set up will not be used. Chatham-Kent needs a system that a first-arriving officer or driver can deploy quickly and run alone if necessary. The requirements, expectations and targets are set out in Appendix B, and Vendors should respond to each.Training, Support and Lifecycle. Vendors should describe the following:Training materials, quick-reference guides and drill scenarios suitable for career and volunteer personnel.Availability of train-the-trainer sessions and on-site support during rollout.Warranty terms, expected service life, and availability and cost of replacement parts and consumables.Customer support hours, response times and escalation path.Options for pilot or trial units before a full purchase.Lead times for delivery of 19 units and any minimum order quantities.There will be no evaluation, ranking or selection of the information received from Potential Partners, and this RFEI will not be used to prequalify or screen any Potential Partners for a subsequent competitive procurement process that may be issued by Chatham-Kent, if any. Please submit your submission no later than 4:00 p.m. on December 10, 2026, via email to Sign up to see this detail

More opportunities from Municipality of Chatham-Kent

Same awarding agency

Get AI-powered intelligence on this solicitation and the ones like it

Every solicitation package arrives shredded into a compliance breakdown and matched to your past performance, with incumbent history and alerts on amendments and award.

Miguel
Hillary
Keith Deutsch
Christine

Join 900+ contractors already using CLEATUS