Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Government Contract opportunity was posted on February 6, 2014. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Request for Information: ADVANCED DEVELOPMENT OF MULTIPLEX DIAGNOSTIC PLATFORMS FOR INFECTIOUS DISEASES

Closed
NIH-AI-2014009Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

General Info

Agency

N/A

NAICS

541712 - Research and Development in the Physical, Engineering, and Life Sciences (except Biotechnology)

Place of Performance

Not specified

Set-Aside

NONE

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

1 update
PhaseClosed
Posted

special-notice

Notice updated

Response deadline changed from Feb 14, 2014 to Feb 25, 2014. The notice description changed.

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyN/A
Contacts2 people available
OfficeN/A
Organization / Agency
N/A
Office AddressN/A
Contacts
Stanley A. Knight SrTeam Lead/Contracting Officer
Jonathan E. BryanContract Specialist

Full Description

Show more
AMENDMENT 1: THE DUE DATE IS EXTENDED TO FEBRUARY 24, 2014. ADVANCED DEVELOPMENT OF MULTIPLEX DIAGNOSTIC PLATFORMS FOR INFECTIOUS DISEASES This is a Request for Information (RFI) only and does not constitute a commitment, implied or otherwise, that the Department of Health and Human Services (DHHS), National Institutes of Health (NIH), National Institute of Allergy and Infectious Diseases (NIAID), will take procurement action in this matter. This is NOT a solicitation for proposals, applications, proposal abstracts or quotations. The purpose of this RFI is to obtain knowledge and information to assess the current state of the science. Further, neither DHHS/NIH/NIAID nor the government will be responsible for any cost incurred in furnishing this information. NIAID is seeking information from diagnostics product developers interested in supporting the advanced development of integrated clinical sample-to-answer multiplex diagnostic technologies to detect emerging and re-emerging infectious diseases (http://www.niaid.nih.gov/topics/emerging/Pages/list.aspx) including NIAID Category A-C Priority Pathogens and other common medically-important pathogens directly from a blood sample, without a blood culture step. The primary focus of this RFI is to gather information about the current product development status of the integrated instrument and potential multiplex diagnostic test. Areas of greatest interest include diagnostics with the following features: - Multiplex diagnostic products designed for use in a primary healthcare setting, which may include one or more of the following: hospital laboratory, Physician's office, health clinics, emergency department, at the bedside, and/or low resource settings; - The multiplex platform will consist of an instrument and multiplex diagnostic test(s) performed using the instrument. The instrument may be a single operating unit capable of accepting a clinical sample, or be composed of a cartridge and cartridge-operating unit. A cartridge is any small modular unit designed to be inserted into a larger piece of equipment. - The instrument should have all components and subsystems (blood sample processing, analyte detection, test result determination and reporting, etc.) completely automated and integrated into an operational unit that does not require any manual manipulation steps after the clinical sample has been loaded on the platform. For example, performance of the diagnostic test must not require manual steps to process and analyze the sample after the blood sample has been transferred from the clinical sample collection container (blood collection tube, etc.) into the entry component of the multiplex diagnostic platform. The entry component may be a tube, cartridge, injection port, or other receptacle into which the clinical sample is transferred to initiate the first processing step within the instrument. Examples of excluded manual steps include shaking, mixing, vortexing, heating, freezing, centrifuging, transferring partially processed samples into new containers (tubes, plates), and/or transferring the sample from one instrument to another instrument. Background Research supported and conducted by the National Institute of Allergy and Infectious Diseases (NIAID) of the National Institutes of Health (NIH), Department of Health and Human Services (HHS), strives to understand, diagnose, treat and ultimately prevent the myriad of infectious, immunologic, and allergic diseases that threaten millions of human lives. The NIAID Division of Microbiology and Infectious Diseases (DMID) supports extramural research to control and prevent diseases caused by virtually all infectious agents with the exception of the Human Immunodeficiency Virus (HIV). This includes basic and applied research to develop and evaluate medical diagnostics, therapeutics and vaccines which are funded through a variety of research grants and contracts. The NIAID also has a mission to advance the development of new medical countermeasures (MCM) against biological agents that are most likely to be used in a terror attack on civilian populations. Information requested Organizations are invited to submit a white paper describing their research efforts towards developing an integrated clinical sample-to-answer multiplex diagnostic product to detect Bacillus anthracis, Yersinia pestis, Francisella tularensis and a minimum of two (2) commonly diagnosed prevalent pathogens with similar early symptoms as the three required biothreat pathogens (fever, malaise, flu-like symptoms, etc.). The pathogens must be detected directly from a blood sample, without a blood culture step. The paper can include but is not limited to: - A description of the integrated instrument, and if appropriate, the cartridge component; - Stage of product development for the instrument, and if appropriate, the cartridge component; - Stage of product development for any existing multiplex diagnostic tests capable of detecting Bacillus anthracis, Yersinia pestis, and Francisella tularensis and common prevalent pathogens directly from a blood sample, including the current status of analytical and clinical studies; - Intended user setting(s); - Data to support that the integrated sample-to-answer multiplex platform is appropriate for the intended use(s); - Description of manufacturing capabilities; - Status of legal rights to the intellectual property or agreements associated with the instrument or diagnostic test Responses should be limited to 10 pages, not including cover page, cover letter and table of contents. Any proprietary information should be clearly identified as such and will be kept confidential as allowed by relevant federal law. Submitted data and information will not be returned. RFI response must include: 1) Name and title of the primary point of contact for the response; 2) Name and address of the Institution or Company; 3) Email address and phone number of the primary point of contact. Responses are due by February 14, 2014. Inquiries Inquiries and RFI responses should be directed to the NIAID Division of Microbiology and Infectious Diseases, Office of Acquisitions, POC Jonathan Bryan, at bryanje@niaid.nih.gov. Alternate POC is Stanley A. Knight, Sr., at knights@niaid.nih.gov.

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS