--Request for Information regarding Commercially Available Steam Sterilizers

Active
USA-SNOTE-061019-001Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

The Army is seeking information on commercially available, ruggedized steam sterilizers suitable for use in combat support hospitals, specifically a gravity steam sterilizer system with a water recovery feature requiring no more than three gallons of water per day and with a chamber size of at least 2.7 cubic feet. The sterilizer must be durable, lightweight, energy-efficient, and easy to operate and maintain in austere field environments. This system is intended to replace an obsolete model and will be used for sterilizing surgical instruments, linens, and other hospital materials in the central materiel sterilization section. Key performance parameters include achieving complete biological kill per AAMI standards at 270-272°F for three minutes with fast exhaust, and meeting strict safety requirements such as ASME boiler and pressure code compliance, FDA approval, electrical code conformity, and noise limits under 85 decibels. Other specifications entail robust, breakage-resistant pressure gauges, safety valves set at 33 PSIG, temperature indicators, and a steam generator capable of at least two sterilization cycles per water refill with an integrated water recovery system. Submissions should include consumable parts, repair components, product information, FDA 510K approval, images, and pricing. The information collected may be used for future evaluations and potential procurement, with responses due by 1200 PM EST on November 2, 2006.

General Info

Army seeks rugged gravity steam sterilizer with water recovery, FDA-approved, durable, energy-efficient, for combat hospitals.

Agency

N/A

NAICS

339113 - Surgical Appliance and Supplies Manufacturing

Place of Performance

Not specified

Set-Aside

NONE

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

Posted

special-notice

Ready to pursue this opportunity?

Get full access to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyN/A
ContactsNo contacts available
OfficeN/A
Organization / Agency
N/A
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
Request for Information regarding Commercially Available Steam Sterilizers The Army is seeking information regarding commercially available off-the-shelf (COTS) ruggedized steam sterilizers. The Army is researching information for a new gravity steam sterilizer system with water recovery feature that uses no more than three gall ons of water per day with a chamber size of not less than 2.7 cubic feet for use in the combat support hospital. Desired sterilizer system will be used in austere field environments, so it is essential that it be rugged, lightweight, easy to use and mainta in, and consume minimal power. The current sterilizer is no longer procurable. These items are necessary in the central materiel sterilization section of the combat support hospital to support sterilization of surgical instruments, linen packs, and other items as required for operation of the hospital. USAMMA is seeking pricing info to accompany the Request for Information (RFI). Essential Characteristics: (KPP=Key Performance Parameter) 1. When operated in accordance with the manufacturers instructions, the sterilizer shall demonstrate the ability to accomplish a complete kill according to AAMI standards for biological kill confirmation and the recommendations of the most recent US Pharm acopoeia. (KPP) A. Operate the sterilizer in accordance with the manufacturers instructions so that the test media in the chamber are exposed to a temperature of 270-272 degrees F for a period of 3 minutes and then exhaust the sterilizing chamber by means of a fast exha ust. B. Shall be able to remove the test media from the chamber in a manner that will preclude contamination. 2. Safety standards: A. Conform to appropriate sections of American Society of Mechanical Engineers (ASME) boiler and pressure code (KPP) B. Have FDA approval (KPP) C. Conform to electrical components requirements of the National Electrical Code (NEC) (KPP) D. Noise level not to exceed 85 decibels IAW Army Regulation 40-5 E. Incorporate safety features for protection of operating and service personnel F. Have time, temperature, and pressure indicators with warning lights and audible signals to alert operator of performance outside established parameters. (KPP) 3. Appropriate pressure gauges for the chamber and jacket shall be installed in the front of the sterilizer. Gauges shall be of a design and construction to render them breakage resistant under projected conditions of rough handling and field service. Crys tals (covers) may be of a suitable plastic. (KPP) 4. Shall have a safety valve meeting ASME standards. Safety valve shall be set for the design pressure (33 PSIG). (KPP) 5. Shall have an indicating thermometer installed that is convenient for observation by the operator. (KPP) 6. Steam generator shall have a water level gauge. (KPP) 7. All materials used for body, support structure, piping, and fittings shall be suitable non-corrosive metals or alloys. Wherever components of dissimilar materials are assembled or in contact, they shall be compatible. (KPP) 8. The sterilizer shall operate safely at steam pressures up to 33 PSIG and shall provide for operation at two temperature ranges at the option of the operator: 250 degrees F and 270 degrees F (to provide flash sterilization). (KPP) 9. The steam generator shall be of sufficient capacity for at least two complete sterilization cycles (including drying time) with one filling of water. The steam generator shall include a water recovery system that requires the addition of less than three gallons of water per day. (KPP) Please include the following items with your submission: 1) Consumable and associated components listings 2) Repair Parts listings 3) Manufacturer product information/instructions 4) 510K (FDA Approval) 5) Product pictures 6) Pricing Information This notice is a Request for Information only. The Army may at a future date evaluate the products via the information received as a result of this RFI in side-by-side testing for possible future contracts. Informational submissions should be made via e-mail or fax to Christopher Gloyd, Contract Specialist, at the following: Fax- +1 (555) 000-0000 or E-Mail- contact@example.gov No telephone calls will be accepted. Response due date and time is 1200 PM EST on 2 November 2006.

Similar Contracts

Same NAICS industry code

Earlier notices in this NAICS code

Posted before this notice, open and closed

Ready to Pursue This Opportunity?

Get AI-powered intelligence on this solicitation and the ones like it

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS