This Solicitation opportunity from Department Of Defense was posted on July 28, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.
RESTRICTOR, FLUID FL
Contract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
Active Opportunities Like This One
AI Contract Overview
This contract pertains to the procurement of one fluid flow restrictor, identified by part number S1E10172 and NSN 4730-01-473-8533, supplied by VACCO Industries under solicitation SPE7M3-26-T-7727. The item is classified as a critical application component and must comply with stringent technical and quality standards referenced in the DLA Master List of Technical and Quality Requirements, which are incorporated by reference. Mercury or mercury-containing compounds are strictly prohibited from intentional addition or direct contact with the hardware, except for specific functional uses such as in batteries, fluorescent lights, sensors, controls, weapon systems, or chemical reagents designated by NAVSEA; portable devices containing mercury must include shockproof construction and a secondary containment barrier per NAVSEA 5100-003D. Delivery is required within 20 days to the USS HYMAN G RICKOVER (SSN 795) in Groton, Connecticut, with shipping to be conducted via the fastest traceable means—parcel post is explicitly forbidden. Packaging must conform to MIL-STD-2073-1E and marking must adhere to MIL-STD-129, with no special marking required. The unit of issue is each, with a fixed quantity of one and zero variance allowed. Inspection and acceptance occur at destination, and the supplier must follow DLA packaging requirements. The contract specifies the original required delivery date as July 23, 2026, and includes government-only tracking codes and shipping instructions for logistics coordination.
General Info
Agency
NAICS
Place of Performance
ATTN: SSN 795, GROTON, CT, 06340-4905, USASet-Aside
Timeline
Submission Closed
Organization & Contact Information
Full Description
RESTRICTOR,FLUID FLOW.
RP001: DLA PACKAGING REQUIREMENTS FOR PROCUREMENT
RA001: THIS DOCUMENT INCORPORATES TECHNICAL AND/OR QUALITY REQUIREMENTS
(IDENTIFIED BY AN 'R' OR AN 'I' NUMBER) SET FORTH IN FULL TEXT IN THE
DLA MASTER LIST OF TECHNICAL AND QUALITY REQUIREMENTS FOUND ON THE WEB
AT:
http://www.dla.mil/HQ/Acquisition/Offers/eProcurement.aspx http://www.dla.mil/HQ/Acquisition/Offers/eProcurement.aspx
FOR SIMPLIFIED ACQUISITIONS, THE REVISION OF THE MASTER IN EFFECT ON THE SOLICITATION ISSUE DATE OR THE AWARD DATE CONTROLS. FOR LARGE ACQUISITIONS, THE REVISION OF THE MASTER IN EFFECT ON THE RFP ISSUE DATE APPLIES UNLESS A SOLICITATION AMENDMENT INCORPORATES A FOLLOW-ON REVISION, IN WHICH CASE THE AMENDMENT DATE CONTROLS.
RQ011: REMOVAL OF GOVERNMENT IDENTIFICATION FROM NON-ACCEPTED SUPPLIES
MERCURY OR MERCURY CONTAINING COMPOUNDS SHALL
NOT BE INTENTIONALLY ADDED TO<(>,<)> OR COME IN DIRECT
CONTACT WITH<(>,<)> ANY HARDWARE OR SUPPLIES FURNISHED
UNDER THIS CONTRACT. EXCEPTION: FUNCTIONAL MERCURY
USED IN BATTERIES, FLUORESCENT LIGHTS, REQUIRED
INSTRUMENTS; SENSORS OR CONTROLS; WEAPON SYSTEMS;
AND CHEMICAL ANALYSIS REAGENTS SPECIFIED BY NAVSEA.
PORTABLE FLUORESCENT LAMPS AND PORTABLE INSTRUMENTS
CONTAINING MERCURY SHALL BE SHOCK PROOF AND CONTAIN
A SECOND BOUNDARY OF CONTAINMENT OF THE MERCURY OR
MERCURY COMPOUND. (IAW NAVSEA 5100-003D).
CRITICAL APPLICATION ITEM
VACCO INDUSTRIES 99517 P/N S1E10172 ITEM 17
VACCO INDUSTRIES 99517 P/N S2C10432-1
DLA issues this document using the DoD authorized unit of issue, please refer to the following URL to determine the corresponding ANSI X12 unit of issue.
https://view.officeapps.live.com/op/view.aspx?src=https%3A%2F%2Fwww.dla.mil%2FPortals%2F104%2FDocuments% 2FDLMS%2FeApplications%2FLogDataAdmin%2FUnitofIssueandPurchaseUnit.xlsx&wdOrigin=BROWSELINK
CLIN PR PRLI UI QUANTITY UNIT PRICE TOTAL PRICE.
0001 7017638925 0001 EA 1.000
NSN/MATERIAL:4730014738533
DELIVERY (IN DAYS):0020
DELIVER FOB: ORIGIN
QTY VARIANCE: PLUS 0% MINUS 0%
SPE7M3-26-T-7727
SECTION B
PR: 7017638925 PRLI: 0001 CONT’D
INSPECTION POINT: DESTINATION
ACCEPTANCE POINT: DESTINATION
PREP FOR DELIVERY:
PKGING DATA MIL-STD-2073-1E
QUP:001 PRES MTHD:10 CLNG/DRY:1 PRESV MAT:00
WRAP MAT:JA CUSH/DUNN MAT:00 CUSH/DUNN THKNESS:0
UNIT CONT:D3 OPI:O
INTRMDTE CONT:DO INTRMDTE CONT QTY:AAA
PACK CODE:U
MARKING SHALL BE IN ACCORDANCE WITH MIL-STD-129.
SPECIAL MARKING CODE:00 -00 No special marking
PALLETIZATION SHALL BE IN ACCORDANCE WITH RP001: DLA PACKAGING REQUIREMENTS FOR PROCUREMENT
PARCEL POST ADDRESS:
N27157
USS HYMAN G RICKOVER (SSN 795)
73 EASTERN POINT RD
ATTN: SSN 795
GROTON CT 06340-4905
US
RDD 777 SHIPMENT. SHIP BY FASTEST TRACEABLE MEANS. DO NOT USE PARCEL POST.
FREIGHT SHIPPING ADDRESS:
N27157
USS HYMAN G RICKOVER (SSN 795)
DLA VENDORS: USE VSM FOR
US
M/F: (TCN) N2715761890802
RDD: 777
PROJ: ZH9 TP 2
SUPP ADD: N48096 SIG: C
FOR GOVERNMENT USE ONLY: (IPD) 06
DIC: A4A DIST: V9B ADV: 2A FC: VO
Need Ship Date:00/00/0000 Original Required Delivery Date:07/23/2026
SPE7M3-26-T-7727 NSN/Part Number: 4730-01-473-8533 Quantity: 1 EA Purchase Request: 7017638925QTY: 1 Delivery: 20 days ADO
More opportunities from Department Of Defense → FLUID HANDLING DIVISION
Same awarding agency
Find Active Opportunities Like This
Get AI-powered intelligence on the opportunities still open
Every page of the solicitation package shredded into a compliance breakdown
AI-powered matching based on your capabilities and past performance
Competitor and incumbent history on the requirement
Automated alerts on amendments, Q&A deadlines, and award
Join 650+ contractors already using CLEATUS
