Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

RFP - Concrete Work & Preparation - OMH Rockland Psychiatric Center Install 2MW Standby Generator

Active
2140161State & Local

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

ADP Group Inc. is soliciting competitive proposals from qualified subcontractors for concrete work and steel bollard installation at the OMH Rockland Psychiatric Center in Orangeburg, New York, to support the installation of a 2MW standby generator. The scope of work includes furnishing and placing approximately 36 cubic yards of 4,500 PSI air-entrained concrete with a smooth, hard-trowel finish for a 47' x 16.5' switchgear pad and an 8' x 8' switch pad. Additionally, the project requires the installation of 13 concrete-filled 6-inch Schedule 80 steel pipe bollards, consisting of eight surface-mounted bollards painted safety yellow and five cast-in-place bollards. All work must adhere to project drawings, specifications, and public works prevailing wage requirements. The project emphasizes diversity and inclusion with specific contracting goals of 18.00% for MBE, 12.00% for WBE, and 6.00% for SDVOB certified firms. Interested subcontractors must provide separate, itemized pricing for concrete placement, formwork, reinforcing steel installation, and bollard installation, along with any exclusions and availability. Proposals are due by October 23, 2026, at 3:00 PM Eastern Time, with an anticipated project start date during the week of October 26, 2026. Submissions should be emailed to the ADP Group Inc. estimating department.

General Info

ADP Group seeks subcontractors for concrete and bollard installation at OMH Rockland.

Agency

Place of Performance

Rockland Psychiatric Center, 140 Old Orangeburg Road, Orangeburg, NY 10962., NY, USA

Set-Aside

NONE

Documents

1

RFP - Concrete Work & Preparation - OMH Rockland Psychiatric Center Install 2MW Standby Generator

PDF, High priority: read this firstrfp
High

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

PhaseSolicitation
Posted

Solicitation

Response Deadline

Submission deadline

Response Deadline

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyNew York
Contacts2 people available
OfficeN/A
Organization / AgencyNew York
Office AddressN/A

Full Description

Show more
ADP Group Inc. is soliciting competitive proposals from qualified subcontractors, including NYS-certified MBE, WBE, and SDVOB firms, for concrete work and steel bollard installation on an active public construction project. We are seeking qualified subcontractors to support the project: OMH Rockland Psychiatric Center Install 2MW Standby Generator located at the Rockland Psychiatric Center, 140 Old Orangeburg Road, Orangeburg, NY 10962. This is a public works project subject to prevailing wage requirements. Scope of Work 1. Concrete Pads – Switchgear and Switch Pads Furnish and place approximately 36 CY of 4,500 PSI air-entrained concrete with a smooth, hard-trowel finish. Furnish and install concrete formwork for the switchgear pad (47' × 16.5') and switch pad (8' × 8'). Bend and install reinforcing steel in accordance with approved shop drawings. Most reinforcing steel is already available on-site. 2. Steel Bollards – 13 Total 8 surface-mounted bollards: 6" Schedule 80 steel pipe, concrete-filled and painted safety yellow, per Detail 12/S-101. 5 cast-in-place bollards: 6" Schedule 80 steel pipe, concrete-filled, per Detail D/C-105. All work must comply with project drawings, specifications, and applicable construction requirements. Contracting Participation Goals ADP Group Inc. encourages participation from certified minority-owned, women-owned, and service-disabled veteran-owned businesses. MBE Goal: 18.00% WBE Goal: 12.00% SDVOB Goal: 6.00% DBE Goal: 0.00% Certified firms are strongly encouraged to submit proposals. Interested subcontractors may submit pricing for individual portions of the scope. Proposal Requirements and Submission Subcontractors shall provide separate, itemized pricing for concrete placement, formwork, reinforcing steel installation, and bollard installation, including any exclusions, qualifications, and anticipated availability. Proposal Deadline: Friday, October 23, 2026, at 3:00 PM Eastern Time. Anticipated Start Date: Week of October 26, 2026. Interested subcontractors should contact ADP Group Inc. to request project drawings, specifications, and supporting documents. Contact: ADP Group Inc. – Estimating DepartmentPhone: (845) 429-2967Email: estimating@adpgrp.com - darko@adpgrp.com - petar@adpgrp.com Submission Instructions: Email proposals with the subject line "Concrete & Bollard Installation – Subcontractor Proposal" before the stated deadline. ADP Group Inc. welcomes competitive proposals from all qualified subcontractors and encourages NYS-certified MBE, WBE, and SDVOB participation. Service-Disabled Veteran-Owned Business (SDVOB) SDVOB Goal: 6.00% Minority / Women Business Enterprise contracting goals (MWBE) MBE Goal: 18.00% WBE Goal: 12.00% Disadvantaged Business Enterprise contracting goals (DBE) DBE Goal: 0.00%

Similar Contracts

Same NAICS industry code

More opportunities from New York

Same awarding agency

Ready to Pursue This Opportunity?

Get AI-powered intelligence on this solicitation and the ones like it

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS