RFP for Material Testing and Deputy Inspection Services - University Student Union Renovation & Expansion
Closed
CSULBSOQ74State & LocalSubmission Closed
Contract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
Active Opportunities Like This One
General Info
Agency
Purchasing Office Department of California State University, Long BeachView Agency
NAICS
541380 - Testing Laboratories and ServicesView NAICS
Place of Performance
1250 Bellflower Blvd. MS 0123 Long Beach, California 90840, CA, USASet-Aside
NONE
Timeline
PhaseClosed
Submission Closed
Organization & Contact Information
Show more
AgencyPurchasing Office Department of California State University, Long Beach
Contacts1 person available
OfficeCA, USA
Organization / Agency
Purchasing Office Department of California State University, Long Beach
View Agency ProfileOffice AddressCA, USA
Contacts
Full Description
Show more
Scope: The office of Design & Construction Services is soliciting fee proposals for material testing and deputy inspection services for the University Student Union Renovation & Expansion Project.
Project Overview The project includes the renovation of 180,000 GSF of the existing University Student Union and a 50,000 GSF addition. The renovated space is a combination of 160,000 SF of indoor space and 20,000 SF of outdoor covered walkways and seating areas.
Schedule: • Construction Start: February 1, 2026 • Completion: May 15, 2028
Scope of Services The required material testing and deputy inspection services shall include, but are not limited to: 1. All required inspections per 2022 California Building Standards Code and project scope of work. 2. Visual inspection of concrete formwork, concrete testing, and reinforcement inspections. 3. Welding inspection for rebar (shop and site) and continuous inspection for placement of all reinforcing steel. 4. Onsite inspection and material testing for unit masonry assemblies, including preconstruction testing and pull test at wall anchors. 5. Inspection of field and shop welds, high strength bolt connections, non-destructive testing, inspection of all erection and identification of all structural steel. 6. Inspection of steel deck welding. 7. Inspection of sheathing and framing. 8. Inspection of all light-gage welding. 9. Inspection of full brick veneer installation. 10. Inspection of stairs and handrails connections (welds, bolts, etc.). 11. Pull test of approximately 10% of acoustical panel ceiling suspension wires. 12. Visual inspections for epoxy/drill in anchors. 13. Inspection of firestop penetrations and joints in accordance with 2022 CBC Section 1705.18. 14. Inspection of sprayed fire-resistive materials and intumescent fire-resistive materials. 15. Inspection and testing of roof top fall arrest anchors in accordance with CalOSHA and other applicable AHJ requirements. Provide unit cost per anchor. 16. Inspection of high-performance coating, of a representative area, on building exterior to confirm dry and wet film thicknesses. 17. Inspection of Fiber Reinforced Polymer (FRP) diaphragm strengthening and associated fire proofing in the existing USU building. 18. Inspection of shoring and lagging system. 19. Laboratory testing as required for reporting preparation. 20. Written daily field reports for each day of inspection and testing. 21. Written reports from in-house engineers as requested by the University. 22. Inclusion of all administrative fees in the proposal. 23. Note: Geotechnical scope of work is not included in this RFP.
Notes: THIS IS AN ADVERTISEMENT ONLY
Access to Documents Plans and specifications are available upon request. Email Lisa.Salgado@csulb.edu to obtain file access to construction documents.
Submission & Contact Information Email proposal to: Lisa.Salgado@csulb.edu Or deliver/mail to: California State University, Long Beach Office of Design and Construction 1331 Palo Verde Ave. Long Beach, CA 90815 Attn: Lisa Salgado
For questions, please contact: Lisa Salgado Phone: (562) 985-1467 Email: Lisa.Salgado@csulb.edu
Project Overview The project includes the renovation of 180,000 GSF of the existing University Student Union and a 50,000 GSF addition. The renovated space is a combination of 160,000 SF of indoor space and 20,000 SF of outdoor covered walkways and seating areas.
Schedule: • Construction Start: February 1, 2026 • Completion: May 15, 2028
Scope of Services The required material testing and deputy inspection services shall include, but are not limited to: 1. All required inspections per 2022 California Building Standards Code and project scope of work. 2. Visual inspection of concrete formwork, concrete testing, and reinforcement inspections. 3. Welding inspection for rebar (shop and site) and continuous inspection for placement of all reinforcing steel. 4. Onsite inspection and material testing for unit masonry assemblies, including preconstruction testing and pull test at wall anchors. 5. Inspection of field and shop welds, high strength bolt connections, non-destructive testing, inspection of all erection and identification of all structural steel. 6. Inspection of steel deck welding. 7. Inspection of sheathing and framing. 8. Inspection of all light-gage welding. 9. Inspection of full brick veneer installation. 10. Inspection of stairs and handrails connections (welds, bolts, etc.). 11. Pull test of approximately 10% of acoustical panel ceiling suspension wires. 12. Visual inspections for epoxy/drill in anchors. 13. Inspection of firestop penetrations and joints in accordance with 2022 CBC Section 1705.18. 14. Inspection of sprayed fire-resistive materials and intumescent fire-resistive materials. 15. Inspection and testing of roof top fall arrest anchors in accordance with CalOSHA and other applicable AHJ requirements. Provide unit cost per anchor. 16. Inspection of high-performance coating, of a representative area, on building exterior to confirm dry and wet film thicknesses. 17. Inspection of Fiber Reinforced Polymer (FRP) diaphragm strengthening and associated fire proofing in the existing USU building. 18. Inspection of shoring and lagging system. 19. Laboratory testing as required for reporting preparation. 20. Written daily field reports for each day of inspection and testing. 21. Written reports from in-house engineers as requested by the University. 22. Inclusion of all administrative fees in the proposal. 23. Note: Geotechnical scope of work is not included in this RFP.
Notes: THIS IS AN ADVERTISEMENT ONLY
Access to Documents Plans and specifications are available upon request. Email Lisa.Salgado@csulb.edu to obtain file access to construction documents.
Submission & Contact Information Email proposal to: Lisa.Salgado@csulb.edu Or deliver/mail to: California State University, Long Beach Office of Design and Construction 1331 Palo Verde Ave. Long Beach, CA 90815 Attn: Lisa Salgado
For questions, please contact: Lisa Salgado Phone: (562) 985-1467 Email: Lisa.Salgado@csulb.edu