Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Solicitation opportunity from California was posted on October 28, 2024. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

RFQ - Imperial County District Attorneys Office Access Control Install

Closed
RFQ 25-0117State & Local

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

AI Contract Overview

Show more

The project involves the installation and configuration of fifteen Isonas RC-04-MCT-WK keypads as part of an access control system for the Imperial County District Attorneys Office in California. The scope includes running and terminating Cat6 cabling from each keypad to a new 24-port patch panel, with cables terminated neatly at both the patch panel and biscuit boxes at the field end for clean and efficient connections. The keypads will be securely mounted at designated locations, ensuring proper alignment and connectivity. Additionally, the installation encompasses the deployment of electric strikes (HES 8300C) on doors requiring controlled access, along with the installation of door sensors (Magnasphere MSS-201C) to monitor door status, all integrated into Isonas' cloud-based system. Pre-installation planning involves a thorough site survey to confirm device locations and cable pathways, as well as a review of the network infrastructure to verify support for PoE or the need for alternative power supplies. The installation tasks include mounting the keypads, installing the necessary cabling infrastructure, and connecting all components to ensure seamless operation. The project is valued between $50,000 and $150,000, with a response deadline of November 26, 2024. The primary contact for this project is Rhoda Hoffman, reachable via email or phone, and further details are accessible through the provided online portal.

General Info

Place of Performance

CA, USA

Set-Aside

NONE

Documents

1

RFQ #25-0117: Office Access Control Install

PDF, High priority: read this firstrfq
High

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

PhaseClosed
Posted

Solicitation

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyCalifornia → Imperial County
Contacts1 person available
OfficeN/A
Organization / AgencyCalifornia → Imperial County
Office AddressN/A

Full Description

Show more
The installation and configuration of 15 Isonas RC-04-MCT-WK keypads, including the necessary Cat6 cabling, termination on a new 24-port patch panel, and the installation of biscuit boxes on the field end. The system will be integrated with Isonas' cloud service, and includes door hardware (HES 8300C), sensors (Magnasphere MSS-201C), and access cards (Isonas TC-2).2.1 Pre-Installation Planning: • Site Survey: Perform a comprehensive site assessment to confirm the locations for keypads, patch panel, biscuit boxes, and cable runs. • Network Infrastructure Review: Ensure that the network can support the new devices, and confirm that power-over-Ethernet (PoE) is available, or appropriate power supply has been arranged. • Cabling Pathways: Determine optimal pathways for Cat6 cabling runs between keypads, biscuit boxes, and the main network infrastructure.2.2 Installation Tasks:Run and Terminate Cat6 Cable: • Install CommScope Cat6 Cable for all 15 Isonas keypads from the keypad locations to the central location housing the 24-port patch panel. • Terminate each Cat6 cable at both ends: ‒ Patch Panel End: Terminate cables neatly in a new 24-port patch panel. ‒ Field End: Terminate each cable into a biscuit box for clean presentation and easy connection to the keypad.Mount Keypads: • Install 15 Isonas RC-04-MCT-WK keypads at designated locations. • Ensure proper alignment and secure mounting according to Isonas specifications. • Connect each keypad to the biscuit boxes for network connectivity.Install Electric Strikes: • Install 15 HES 8300C concealed electric strikes on doors where access control is required. • Ensure that electric strikes are properly aligned with the doors for smooth locking and unlocking.Install Door Sensors: • Install 15 Magnasphere MSS-201C door contact sensors in appropriate locations. • Wire sensors into the access control system to detect door status (open/closed).

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown