Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Justice was posted on November 27, 2019. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Roof Repair

Closed
15BDUB2019Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

General Info

NAICS

23816

Place of Performance

Dublin, CA, 94568, USA

Set-Aside

NONE

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Justice → Fci Dublin
Contacts2 people available
OfficeDUBLIN, CA, 94568, USA
Office AddressDUBLIN, CA, 94568, USA

Full Description

Show more
Sources sought to make repairs to a flat roof with asphalt shingles that is leaking in multiple places. Breif description of repair needed but not limited to are. Gutter area; Remove three rows of shingles above the gutter from side to side. Remove/fold up metal counter Z flashing. Install 60mil TPO over entire gutter, glued down to existing metal gutter. Install three rows of new shingles (simular to existing material) Fold down metal Z flashing, attach with new screws & neoprene washers. At A/C area; Clean/wash existing surface around A/C Unit approx 5 feet from Unit. Mastic 3 coarse any cracks or blemishes in the cleaned area. Install silicone coating with primer and top coat in area around A/C unit. Clean and haul away all repair related debris.

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS