Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Defense was posted on January 31, 2025. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

SAOC 2-Bay Maintenance Hangar

Closed
W9128F25SM019Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

General Info

NAICS

541330 - Engineering Services

Place of Performance

Offutt AFB, NE, USA

Set-Aside

NONE

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

1 update
PhaseClosed
Posted

Sources Sought

Notice updated

The notice description changed.

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → W071 Endist Omaha
Contacts2 people available
OfficeOMAHA, NE, 68102-4901, USA
Office AddressOMAHA, NE, 68102-4901, USA
Contacts

Full Description

Show more
Sources Sought Response Form SAOC 2-Bay Maintenance Hangar - 35% to RTA AE Design Offutt AFB, NE Sources Sought Notice # W9128F25SM019 PURPOSE: By way of this Sources Sought Notice, the USACE-Omaha District intends to determine the extent of capable small business or other than small business firms that are engaged in providing the requirement described hereunder. The responses to this notice will be used for planning purposes for upcoming procurements. Therefore, this notice does not constitute a Request for Proposal (RFP), Quotation or Bid; it does not guarantee the future issue of an RFQ/RFP/IFB; nor does it commit the government to contract for any supply, service, or construction. There is no solicitation currently available. Further, this Agency will not accept unsolicited proposals. Respondents are advised that this Agency will not pay for any information or administrative cost incurred in response to this Notice. All costs associated with responding to this Notice will be solely at the responding party's expense. At this time, proprietary information is not being requested, and respondents shall refrain from providing proprietary information in response to this Sources Sought Notice. PROJECT DESCRIPTION: Progress an already completed 35% design through Ready-to-Advertise (RTA), Construction Contract Award, and Construction Phase Services for a new 2-bay maintenance hangar, with potentially an option for an additional 1-bay fuel cell and corrosion control hangar (subject to the availability of funds), to support the Air Force's new Survivable Airborne Operations Center (SAOC) airframe. This project provides a fully enclosed 314,600 SF 2-bay maintenance hangar with Operations (OPS) to accommodate maintenance activities for two (2) fully enclosed Boeing 747-8i aircraft. This facility will also house an Aircraft Maintenance Unit (AMU); 68,000 SF of consolidated tool kit (CTK) space; and 78,000 of contractor logistics support (CLS) supply space. The project's construction includes, but is not limited to, concrete foundation and floor slab, steel high bay, standing seam metal roof, dual bridge crane telescopic maintenance platforms, motorized hangar doors and tracks, fire alarm and suppression system to include cranes, and all necessary support. Aircraft hangar requires such areas as administrative, tool room, supply/bench stock area, storage, shop areas, emergency shower and eyewash stations, locker areas with shower, and break area. Includes secure space. Sensitive and/or Special Access Program spaces shall comply with the Intelligence Community Directive 705 criteria and standards. This project is authorized a generator, per AFI 32-1062. Includes utilities, pavements, site improvements, communications and all other necessary support to provide a complete and useable facility. Hangar access airfield pavements will clear, excavate, place base material and concrete pavement, asphalt shoulder, airfield markings, storm water retention, storm drainage, lighting and all other necessary support. Appropriate cybersecurity measures will be applied to the facility-related control systems in accordance with current DoD criteria. Facility will be designed as permanent construction in accordance with Department of Defense Unified Facilities Criteria 1-200-01. This project will comply with Department of Defense antiterrorism/force protection requirements per Unified Facilities Criteria 4-010-01. This project may include the design of a 1-bay fuel cell and corrosion control hangar. This project provides a fully enclosed 141,000 SF 1-bay Fuel Cell and Corrosion Control hangar to accommodate maintenance activities for one fully enclosed Boeing 747-8i aircraft. This facility will also house a storage space for various vehicles and winter ops (6,500 SF). The project's construction includes, but is not limited to, concrete foundation and floor slab, steel high bay, standing seam metal roof, motorized hangar doors and tracks, fire alarm and suppression system, and all necessary support. Aircraft hangar requires such areas as administrative, tool room, supply/bench stock area, storage, shop areas, emergency shower and eyewash stations, locker areas with shower, and break area. Includes utilities, pavements, site improvements, communications and all other necessary support to provide a complete and useable facility. Hangar access airfield pavements will clear, excavate, place base material and concrete pavement, asphalt shoulder, airfield markings, storm water retention, storm drainage, lighting and all other necessary support. Appropriate cybersecurity measures will be applied to the facility-related control systems in accordance with current DoD criteria. Facility will be designed as permanent construction in accordance with Department of Defense Unified Facilities Criteria 1-200-01. This project will comply with Department of Defense antiterrorism/force protection requirements per Unified Facilities Criteria 4-010-01. Estimated Project Solicitation Issue date: May 2025 Small Businesses are reminded under FAR 52.219-14(c)(1), Limitations on Subcontracting Services, at least 50 percent of the cost of contract performance incurred for personnel shall be expended for employees of the concern. Prior Government contract work is not required for submitting a response to this Sources Sought synopsis. RESPONSES: Please respond to all information requested in this notice not later than 2pm Central Time 18 February 2025. Please include the Sources Sought Notice Identification Number in the subject line of the email submission with Attention to: SFC Trisha Connors, trisha.k.connors@usace.army.mil and Jessica Jackson, jessica.r.jackson@usace.army.mil. REQUIRED INFORMATION TO BE SUBMITTED IN RESPONSE TO THIS NOTICE: 1. Company Name, address, phone number, point of contract, email, web address: 2. CAGE Code and Unique Entity Identifier (UEI): 3. North American Industry Classification System Code (NAICS): 4. State whether your firm is classified by the Small Business Administration as any of the following: Small Business Small Disadvantaged Business Service-Disabled Veteran Owned Small Business (SDVOSB) Section 8(a) Women Owned Small Business (WOSB) HUBZone Historically black colleges and Universities/Minority Institutions None of the above 1. Is your company currently registered in System for Award Management (SAM)? 2.Has your company performed work for the federal government under a different name or UEI/DUNS #, or as a member of a Joint Venture (JV)? If yes, provide an explanation: CAPABILITIES and SUBMISSION REQUIREMENTS: 1.What experience does your company have in designing Department of Defense (DoD) hangars for wide-body commercial derivative aircraft? 2.What experience does your company have in designing spaces in accordance with ICD 705 standards? 3.What experience does your company have in completing full designs for a facility 300,000 square feet or larger? SUBMISSION DETAILS: All interested, capable, qualified, and responsive contractors under NAICS code 541330, Engineering Services are encouraged to reply to this request. Interested PRIME CONTRACTORS ONLY should submit a narrative demonstrating their experience in construction projects of similar nature as described in the Project Description. Narratives shall be no longer than 3 pages. Email responses are required. Please include the following information in your response/narrative: - Company name, address, and point of contact, with phone number and email address - CAGE Code and DUNS/EID number - Business size to include any official teaming arrangements as a partnership or joint venture - Details of similar projects and state whether you were the Prime or Subcontractor - Project references (including owner with phone number and email address) - Project cost, duration, and complexity of job - Information on your bonding capability - SPECIFICALLY IDENTIFY CAPACITY OF PERFORMANCE AND PAYMENT BONDS - Not Applicable In accordance with DFARS 236.204, the magnitude of the construction project associated with this AE requirement is expected to range over $500,000,000. COMMENTS: Provide comments or identify any concerns your company has regarding the planned solicitation. Note that the Government will not be responding to inquiries about the proposed solicitation at this time. Your responses and comments will be used by Government personnel to assess the viability and scope of the proposed solicitation and will be kept in strictest confidence. Telephone inquiries will not be accepted.

More opportunities from Department Of Defense → W071 Endist Omaha

Same awarding agency

NAICS: 237990
New
Federal
LOWER BRULE NORTH SHORELINE STABILIZATION AND ECOSYSTEM RESTORATION, ELEMENT 2
Solicitation # W9128F27BA007
The USACE Omaha District intends to award a contract for the Lower Brule North Shoreline Stabilization and Ecosystem Restoration, Element 2, located in Big Bend, Lower Brule, South Dakota. This project is a 100 percent Small Business Set-Aside under NAICS code 237990, with estimated construction costs ranging from 10 million to 25 million dollars. The scope of work involves the construction of a 100-foot-wide riparian planting bench, a gravel maintenance path, and the creation of a 200-by-1,500-foot island in Reach 4 of the lake. This island will be planted with cottonwood trees and culturally significant vegetation, protected by a riprap revetment to prevent erosion from wind, waves, and ice. These efforts are expected to create approximately 32 acres of riparian habitat and 5.17 acres of emergent wetland. The government plans to issue the Invitation for Bid on approximately October 6, 2026, with a closing date around November 10, 2026, and a scheduled site visit on October 28, 2026. The selected contractor must complete the work within 450 days of receiving the Notice to Proceed, and the contract will include provisions for liquidated damages and requirements for both performance and payment bonds. Bids must be submitted through the Procurement Integrated Enterprise Environment Solicitation Module, and all offerors must maintain an active and verified account in the System for Award Management.
Other Heavy and Civil Engineering Construction

POSTED

4 days ago

DEADLINE

N/A
View Details
NAICS: 237990
New
Federal
Construct Interim Remedial Action (IRA) for the Nelson Tunnel Superfund Site
Solicitation # W9128F27RA056
The USACE Omaha District intends to issue Request for Proposal W9128F27RA056 in November 2026, with a planned proposal due date in January 2027. This unrestricted solicitation, open to both small and large businesses, seeks construction services for the Interim Remedial Action at the Nelson Tunnel Superfund Site located near Creede, Colorado. The project, estimated between 15 million and 30 million dollars, aims to prevent the uncontrolled release of mine-impacted water from an abandoned underground hard rock mine. The scope of work includes the installation of a new bypass adit south of the Nelson Tunnel, rehabilitation of the tunnel from the bypass connection to the bulkhead location, the installation of a flow control bulkhead within the Nelson Tunnel, and the construction of an accessible bulkhead flow control structure in the Commodore 5 level. The contract will be awarded based on a best-value approach, evaluating technical merit and price. Technical evaluation factors include project management approach and schedule, past performance, key personnel, and small business participation, with technical factors rated adjectivally and price assessed for reasonableness and realism. Performance is expected to begin within 10 days of the Notice to Proceed and must be completed within a duration not exceeding 655 days. Interested parties must be registered in SAM.gov with NAICS code 237990 and registered in the Procurement Integrated Enterprise Environment (PIEE) as a Proposal Manager to receive documents and submit proposals. Site visits are subject to safety briefings and specific equipment requirements for underground entry.
Other Heavy and Civil Engineering Construction

POSTED

4 days ago

DEADLINE

in about 1 month
View Details
NAICS: 238220
New
Federal
Cooling Water System Repair and Reliability Project
Solicitation # W9128F26XICGB
The U.S. Army Corps of Engineers Omaha District is seeking capability statements for the Cooling Water System Repair and Reliability Project at Cavalier Space Force Station, ND. This project, estimated between 50 million and 70 million dollars, involves the comprehensive rehabilitation and modernization of a large-scale industrial cooling water system. The scope of work includes installing new fluid coolers, pumps, distribution loops, and a redundant heat exchanger arrangement, as well as the demolition and replacement of 24-inch piping. Critical requirements include maintaining full operational continuity of the system throughout construction to support national defense missions, adhering to HEMP requirements, and performing ACM abatement. The government intends to utilize a Progressive Design-Build approach via an Other Transaction Authority agreement under 10 U.S.C. 2808a, which operates outside the Federal Acquisition Regulation. Selection will be based on qualifications rather than price, focusing on team composition and past relevant experience. The anticipated schedule begins with design in the second quarter of fiscal year 2027, followed by construction in the fourth quarter of the same year. Interested firms must be registered in SAM.gov, capable of bonding at least 70 million dollars for a single project, and compliant with Cybersecurity Maturity Model Certification Level 1.
Plumbing, Heating, and Air-Conditioning Contractors

POSTED

4 days ago

DEADLINE

in 6 days
View Details
NAICS: 238990
Federal
GARRISON TRASH RACK MODIFICATION CRANE RENTAL
Solicitation # W9128F26QA099
Solicitation W9128F26QA099 is a firm-fixed-price service contract issued by the U.S. Army Corps of Engineers, Omaha District, for the rental of a crane and a qualified operator at the Garrison Dam near Riverdale, North Dakota. The primary objective is to support the modification of intake trash racks to conserve cool waters for fishery missions during drought conditions. The contractor is responsible for providing all equipment, tools, vehicles, and supervision necessary to lift and lower trash racks weighing between 30,000 and 33,000 pounds, with the capacity to overcome friction factors up to 41,000 pounds. The period of performance is scheduled from October 30, 2026, through June 30, 2027. This procurement is a total set-aside for Women-Owned Small Businesses and Economically Disadvantaged Women-Owned Small Businesses under NAICS 238990. Award will be based on the most advantageous offer, evaluating price alongside technical information and past performance, including three project examples from the last two years. Key compliance requirements include adherence to EM 385-1-1 safety standards, the submission of a site-specific Accident Prevention Plan and Lift Plan, and compliance with Service Contract Act wage determinations for North Dakota. Following Amendment 0001, the closing date for the submission of offers has been extended to October 23, 2026, at 2:00 PM.
All Other Specialty Trade Contractors

POSTED

7 days ago

DEADLINE

in 3 days
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS