This Solicitation opportunity from Department Of Defense was posted on April 29, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.
SENSOR, OXYGEN ANALY
Contract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
Active Opportunities Like This One
AI Contract Overview
The contract is for a single unit of a general-purpose self-contained oxygen sensor with a measurement range selectable among 0–25%, 0–50%, or 0–95%, and a standard analog output of 0–2.5 VDC with an optional isolated 4–20 mA output. The sensor is designed for use in non-flammable samples, features a stable long-life design, and operates within a temperature range of 0°F to 130°F with a nominal power requirement of 24 VDC, drawing approximately 250 mA at 12 V, with current draw varying inversely with supply voltage. The unit of issue is each, and delivery is required within five days to Edwards Air Force Base, California, under FOB destination terms, placing risk of loss on the government upon arrival. Pricing is listed between $742.00 and $982.00 depending on configuration, though the quoted contract line item price is $1,148.00, suggesting additional integrated costs. Specific options—including measurement range, output type, and fitting type (diffusion screen, compression, or barbed)—must be selected by the customer before final quote issuance. The item is identified by NSN 6630-01-680-1727 and falls under NAICS 334515 for other commercial and industrial machinery manufacturing. The procurement is governed by the DLA Master List of Technical and Quality Requirements, with packaging complying with ASTM D3951 and marking adhering to MIL-STD-129 or the Medical Marking Standard No. 1 for medical acquisitions; palletization follows RP001 DLA guidelines. Cybersecurity requirements under DFARS 252.204-7012 and NIST SP 800-171 apply, mandating safeguarding of covered defense information and incident reporting. Hazardous materials must be labeled per OSHA’s Hazard Communication Standard and MIL-STD-129. Payment is processed via WAWF using an Invoice and Receiving Report format. The contract is issued under solicitation SPE2DS-26-T-031R with a response deadline of May 5, 2026. The contracting activity is the Department of Defense, Medical Supply Chain MD Surg FSF, and the solicitation allows for an alternate contract type under deviation 2026
General Info
Agency
Contract Value
$1,147NAICS
Place of Performance
120 N ROSAMOND BLVD BLDG 3735, EDWARDS AFB, CA, 93524-8600, USASet-Aside
Awardee
Award Issued Date
Timeline
Submission Closed
Organization & Contact Information
Full Description
SENSOR,OXYGEN ANALY GENERAL PURPOSE SELF-CONTAINED OXYGEN SENSOR:
PERCENT OXYGEN IN NON-FLAMABLE SAMPLES; EXTREMELY STABLE, LONG-LIFE
SENSOR; STANDARD 0-2.5VDC OUTPUT: ISOLATED 4-20MA OUTPUT OPTIONAL.
OPERATING TEMPERATURE: 0 DEG F TO 130 DEG F. POWER REQUIREMENTS: BETWEEN
7 AND 28 VDC (NOMINALLY 24VDC) TYPICALLY 250 MA AT 12VWITH NO EXTERNAL
DRAW FROM THE 5V SUPPLY. CURRENT DRAW IS HIGHER AT LOWER VOLTAGE AND
LOWER AT HIGHER VOLTAGE.
. UNIT OF ISSUE EACH (EA).
NOTE TO BUYER
CUSTOMER WILL NEED TO BE CONTACTED IN ORDER TO SELECT
OPTIONS.
This model needs some options to be selected in order to provide a complete quote.
Please advise on the following required options:
1. Measurement Range: 0-25%, 0-50%, or 0-95%?
2. Analog output: 0-2.5VDC or 4-20mA?
3. Diffusion screen, compression fittings, or barbed fittings?
Price on probes are either $742.00 or $982.00
CONTACT INFO AMI INSIDE SALES Derek Johnsondjohnson@amio2.com(714) 848-5533
. RA001: THIS DOCUMENT INCORPORATES TECHNICAL AND/OR QUALITY REQUIREMENTS (IDENTIFIED BY AN 'R' OR AN 'I' NUMBER) SET FORTH IN FULL TEXT IN THE DLA MASTER LIST OF TECHNICAL AND QUALITY REQUIREMENTS FOUND ON THE WEB AT:
http://www.dla.mil/HQ/Acquisition/Offers/eProcurement.aspx http://www.dla.mil/HQ/Acquisition/Offers/eProcurement.aspx
FOR SIMPLIFIED ACQUISITIONS, THE REVISION OF THE MASTER IN EFFECT ON THE SOLICITATION ISSUE DATE OR THE AWARD DATE CONTROLS. FOR LARGE ACQUISITIONS, THE REVISION OF THE MASTER IN EFFECT ON THE RFP ISSUE DATE APPLIES UNLESS A SOLICITATION AMENDMENT INCORPORATES A FOLLOW-ON REVISION, IN WHICH CASE THE AMENDMENT DATE CONTROLS.
RP001: DLA PACKAGING REQUIREMENTS FOR PROCUREMENT
RQ011: REMOVAL OF GOVERNMENT IDENTIFICATION FROM NON-ACCEPTED SUPPLIES
ADEQUATE DATA FOR THE NSN/Part Number: 6630-01-680-1727 Quantity: 1 EA Purchase Request: 7016505048QTY: 1 Delivery: 5 days ADO
More opportunities from Department Of Defense → MEDICAL SUPPLY CHAIN MD SURG FSF
Same awarding agency
Find Active Opportunities Like This
Get AI-powered intelligence on the opportunities still open
Every page of the solicitation package shredded into a compliance breakdown
AI-powered matching based on your capabilities and past performance
Competitor and incumbent history on the requirement
Automated alerts on amendments, Q&A deadlines, and award