This solicitation, identified as SERV26*375271, outlines requirements for fire alarm maintenance and repairs at the Folsom Building located at 64 North Union Street in Montgomery, Alabama. The primary scope of work involves replacing batteries for six different fire alarm panels located throughout the facility, including the penthouse, basement, and various floors. Additionally, the project requires the removal of an old smoke detector on the 6th floor, the installation of a wall strobe in the 1st-floor men's restroom, and the replacement of several ceiling-mounted speakers and strobes in specific suites using customer-provided parts. Technical troubleshooting is also required for a door holder in the 1st-floor Ripley Street Wing lobby and the 4th-floor lobby interface, which may necessitate coordination with handicap door and access control companies as well as JCI programming. Bidders are required to provide unit pricing for twelve specific batteries of varying voltages and capacities, along with a quoted labor rate and a trip charge. The solicitation was posted by the Alabama Capitol Maintenance and Repair agency, with a response deadline of August 27, 2026. Interested parties must submit their quotes according to the specified line items to ensure compliance with the procurement process. For technical inquiries regarding the scope of work, contact is directed to Johnny Willis.

General Info

Fire alarm maintenance, battery replacement, and repairs at Montgomery, Alabama Folsom Building.

Agency

Alabama → Capitol Maintenance & Repair _ ABRFAView Agency

NAICS

N/A

Place of Performance

AL, USA

Set-Aside

NONE

Documents

(2)

SRC0000035596 | Quick Quote Standard Boilerplate

PDF

SRC0000035596 | specs

DOCX

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

PhaseSolicitation
Posted

Solicitation

Response Deadline

Submission deadline

Response Deadline

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyAlabama → Capitol Maintenance & Repair _ ABRFA
Contacts1 person available
OfficeAL, USA
Organization / Agency
Alabama → Capitol Maintenance & Repair _ ABRFA
View Agency Profile
Office AddressAL, USA
Contacts
Stephanie Hastings

Full Description

Show more
Fire Alarm Battery Replacement FBFacility: Folsom Building, 64 North Union Street, Montgomery, ALScope of Work: Replace Fire Alarm Panel Batteries: Penthouse Fire Panel, 6th Floor Fire Panel, 2nd Floor Fire Panel, 1st Floor Fire Panel, 1st Floor Second Fire Panel, Basement Fire Panel Remove Old Smoke Detector, 6th Floor Closet by Women's Restroom Replace Speaker/Strobe, Ceiling Suite 421-B (Use customer's part) Replace Speaker/Strobe, Ceiling, Suite 356-G (Use customer's part) Replace Speaker/Strobe, Ceiling, Suite 106 by Room J (Use customer's part) Replace Strobe, Wall, 1st Floor Men's Restroom, Monroe Lobby Troubleshoot 1st Floor Ripley Street Wing Lobby Door Holder ** Do Not Prop Open Fire Doors** 4th Floor Lobby to North and South Wings Held Open on Alarm; Have HandicapDoor Company check Fire Alarm Interface** Have Access Control Company look at the fire interface**Needs JCI ProgrammingParts Needed: Battery, 12 Volt 75 Amp Hour Quantity-6 Battery, 12 Volt 50 Amp Hour Quantity-4 Battery, 12 Volt 35 Amp Hour Quantity-2 Simplex Addressable Wall Strobe, White, 49VO-WWA Quantity-1 Solicitation Instructions:Enter unit price for lines 1, 2, 3 & 4 corresponding with the items listed above.Please quote labor rate on line 5 of the solicitation. Please quote trip charge on line 6 of the solicitation.Any questions please contact:Johnny WillisJohnny.willis@rpm.alabama.gov334-850-6817

More opportunities from Alabama → Capitol Maintenance & Repair _ ABRFA

Same awarding agency

New
SLED
SERV27*375323Gate Arms & Roll Up Doors Maintenance Agreement
Solicitation # SRC0000035604
The State of Alabama, through Capitol Maintenance and Repair, is soliciting bids for a 12-month contract to provide preventative maintenance and miscellaneous repairs for roll-up doors, security grills, and gate arm operators. The service period runs from October 1, 2026, through September 30, 2027, covering five specific facilities in downtown Montgomery: the Administrative Building, Annex Building, Alabama Archives and History Building, Folsom Administration Building, and Gordon Persons Building. The contract has a total value ceiling of 25,000 dollars and may be renewed annually for up to five years. Bidders must possess at least five years of relevant experience, provide three professional references, and attend a mandatory site visit on August 28, 2026. Proposals must include quarterly maintenance pricing per facility, hourly labor rates for repairs, and a percentage discount for materials. The selected contractor must provide all labor, equipment, and supervision, strictly adhering to OSHA regulations and professional conduct standards. Notably, the use of subcontractors is prohibited, and the contractor must respond to emergency repair notifications within 24 hours if facility security or ingress/egress is compromised. Compliance with the Beason-Hammon Act via E-Verify and registration in the Alabama Buys portal are mandatory requirements for award.

POSTED

about 5 hours ago

DEADLINE

in 9 days
View Details
New
SLED
SERV26*375253 Fire Alarm Battery Replacement LBW
Solicitation # SRC0000035594
Solicitation SRC0000035594, issued by the Alabama Capitol Maintenance and Repair agency, seeks a contractor to replace fire alarm panel batteries at the Lurleen B. Wallace Building located at 501 Dexter Avenue in Montgomery, Alabama. The scope of work includes replacing batteries across all floors from the 1st through the 9th, specifically requiring sixteen 12V 25Ah batteries and two 12V 75Ah batteries. The contractor must also address specific facility issues, including verifying smoke detector requirements for IDF Room 4.2 on the 4th floor, noting the absence of fire fighter phones in elevators 1-4, and addressing a non-functional air handler shutdown function in the 9th floor North Mechanical Room. Bidders are required to provide unit pricing for the batteries, as well as labor rates and trip charges. The contract is governed by Alabama state law and includes a not-to-exceed ceiling of 25,000 dollars, with a potential term of up to five years through annual renewals. Award is implied to be based on the lowest price technically acceptable criteria. Mandatory compliance requirements include E-Verify enrollment, Alabama sales tax registration, and certification that the entity is not debarred or suspended. All proposals must be submitted electronically via the Alabama Buys portal by the deadline of August 27, 2026. Inspection and final acceptance of the work will be conducted by the State of Alabama at the place of performance upon satisfactory completion of the battery replacements and system verification.