Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Sources Sought opportunity was posted on February 9, 2012. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Signal Conditioning Amplifier

Closed
F1S0AE-0510GA1A4Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

General Info

Agency

N/A

NAICS

335999 - All Other Miscellaneous Electrical Equipment and Component Manufacturing

Place of Performance

Not specified

Set-Aside

SBA

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyN/A
Contacts1 person available
OfficeN/A
Organization / Agency
N/A
Office AddressN/A
Contacts
Grace H. WatsonAcquisition Project Specialist

Full Description

Show more
Sources Sought Synopsis - Signal Conditioning Amplifier This is a sources sought synopsis. The Air Force Flight Test Center (AFFTC), 412 Test Engineering Group (TENG), Edwards AFB CA is looking for sources with a demonstrated expertise and experience for a contract to provide brand name or equal compatible hardware and software products meeting the minimum salient characteristics: Item: Signal Conditioning Amplifier, QTY: 5 each Model: 0510GA1A4 Manufacturer: Goodrich Rosemount Aerospace, Inc. SPECIFICATIONS PRT Compatibility -Ice point (R0) of 50, 100 or 500 ohms -Temperature coefficient (a) of .00385, .00390, .003915 or .003925 ?/?C PRT Leadwire Connections -Three wire with 0.25? maximum leadwire resistance Accuracy -Signal conditioner output will be within - 0.25% of Full Scale (FS) for all inputs. Accuracy is based on Root-Sum-Squared (RSS) summation of the following error components: - Long-Term Stability: 0.05% FS (maximum) - Repeatability: 0.1% FS (maximum) - Linearity: 0.15% FS (based on least-squares method) - Temperature Sensitivity: 0.002% FS/C (maximum) - Supply Sensitivity: 0.01% FS/volt (maximum) Momentary Power Interruption: Automatic recovery Signal Conditioner Temperature Range Operating: -54'C to +71'C (-65'F to +160'F) Storage: -65'C to +125'C (-85'F to +257'F) Reliability Mean Time Between Failure (MTBF) is greater then 100,000 hours (based on MIL-HDBK-217E). Maintainability No scheduled maintenance. Signal conditioner can be repaired and recalibrated. ELECTRICAL SPECIFICATIONS Input Voltage: 28 VDC (nominal) 22-32 VDC Power Requirements: 2 watts (maximum) Output Voltage: 0-5 VDC (nominal) Output Load: 5000 ohms (minimum) Output Isolation: 150K ohms (minimum) from the supply voltage Short Circuit Protection -No damage from continuously shorted output leads Reverse Polarity Protection -No damage from continuously reversed power leads Dielectric Strength: 100 VAC (rms) Insulated Resistance: 100 Megohms (min) at 100 VDC Weight: 7.2 ounces maximum ENVIRONMENTAL SPECIFICATIONS Explosive Atmosphere -Tested to MIL-STD-810, Method 511.1, Procedure I Temperature-Altitude -Tested to MIL-STD-810, Method 504.1, Procedure I Humidity -Tested to MIL-STD-810, Method 507.1, Procedure I Salt Fog -Tested to MIL-STD-810, Method 509.1, Procedure I Fungus -Meets MIL-STD-810, Method 508.1, Procedure I Dust -Tested to MIL-STD-810, Method 510.1, Procedure I Shock -15g's, 11ms, half sine (Tested to MIL-STD-810, Method 516.2, Procedure I) Acoustic Noise -140 db for 30 minutes (Tested to MIL-STD-810, Method 515.2, Procedure I) Random Vibration -Wo = .04 g2/Hz, 2 hours/axis operating (Tested to MIL-STD-810, Method 514.2)

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown