Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Government Contract opportunity from Department Of Defense was posted on March 7, 2024. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Synopsis - Pavement Condition Survey & MicroPAVER Reinspection, Fort Campbell Roads, Kentucky

Closed
W9128F24R0017Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 541330
New
SLED
2026 AC Water Main Replacement
Solicitation # 2026-RFQ-042
Solicitation 2026-RFQ-042 is a request for qualifications from the City of Mercer Island Public Works department for professional engineering services to design water system upgrades. The project focuses on replacing approximately 5,000 linear feet of aging asbestos cement water mains with ductile iron mains along SE 40th St and E Mercer Way. The scope is divided into two phases: Phase 1 involves water system and PRV vault replacement on SE 40th St from Greenbrier Ln to 97th Ave SE, and Phase 2 extends the replacement to 97th Ave SE and the 3700 and 3800 blocks of East Mercer Way. Additional components for replacement include fire hydrants and water services. The design must comply with the Reduction of Lead in Drinking Water Act and the City of Mercer Island Standard Details Water. The project follows a goal-based timeline with bid-ready plans for Phase 1 due by Q2 2027 and Phase 2 by Q3 2027, with overall construction completion targeted for Q2 2028. Qualified firms must be licensed in the State of Washington and submit a Statement of Qualifications limited to 12 pages, including a proposed timeline and three references from the last five years. Selection is at the sole discretion of the City, and the awarded firm will negotiate a scope and fee schedule using the City's standard professional services agreement. Administration is managed by the City Manager, with payments issued via City warrant within 45 days of receiving a proper monthly invoice.
Public Works

POSTED

about 9 hours ago

DEADLINE

in 14 days

General Info

NAICS

541330 - Engineering Services

Place of Performance

Fort Campbell, KY, 42223, USA

Set-Aside

SBA

Documents

4

AM-0001 Draft Solicitation with Scope of Work

DOCX, High priority: read this first40 pages · amendment
High

Draft Solicitation with Scope of Work

DOCX, High priority: read this firstrfp
High

Fort Campbell Roadways Branch Listing Report

PDF, High priority: read this firstspecifications
High

PAVER Implementation Final Report - U.S. Army Garrison, Adelphi Laboratory Center

PDF, Low priorityfinal-report
Low

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

3 updates
PhaseClosed
Posted

Presolicitation

Notice updated

Notice type changed from Presolicitation to Special Notice. Response deadline changed from Oct 27, 2023 to Mar 25, 2024. The notice title changed. NAICS code changed from 541620 to 541330. The notice description changed. The point of contact changed.

Notice updated

The notice description changed.

Notice updated

The notice description changed.

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → W071 Endist Omaha
Contacts2 people available
OfficeOMAHA, NE, 68102-4901, USA
Office AddressOMAHA, NE, 68102-4901, USA
Contacts
Brandon Landis

Full Description

Show more
Amendment 0002 Date of Issue: 07 March 2024 Date of Receiving Responses to Synopsis: Remains 25 March 2023 at 2:00 p.m. Central Time There are no updates to the attachments. Corrections to the Synopsis is as follows: The SF 330, 07/2021 edition, must be used, and may be obtained from the following website: https://www.gsa.gov/reference/forms/architectengineer-qualifications Amendment 0001 Date of Issue: 01 February 2024 Date of Receiving Responses to Synopsis: Remains 25 March 2023 at 2:00 p.m. Central Time See attached AM-0001_Draft Solicitation with Scope of Work which updates the page 1 (SF 1449) box 10 to - Small Business as highlighted. Corrections to the Synopsis are as follows: The Bidder Inquiry Key is: G97KIV-I374E8 Questions should be submitted no later than 15 March 2024 at 2:00 p.m. Central Time to allow time for a response. Synopsis of A-E Services Pavement Condition Survey & MicroPAVER Reinspection, Fort Campbell Roads, Kentucky CLASSIFICATION CODE: Service Code C (Architect and Engineering Services) SUBJECT: PAVEMENT CONDITION SURVEY & MICROPAVER REINSPECTION, FORT CAMPBELL ROADS, KENTUCKY DESCRIPTION: 1. CONTRACT INFORMATION. THIS SOLICITATION IS RESTRICTED TO SMALL BUSINESS PARTICIPATION The North American Industry Classification System (NAICS) is 541330 - Engineering Services and Small Business Size Standard is $25.5M. This contract is being procured in accordance with the Brooks A-E Act as implemented in FAR Subpart 36.6. Firms will be selected for negotiation based on demonstrated competence and qualifications for the required work. Contract Type: This will be a single Firm Fixed Price (FFP) purchase order. Performance Period: Twelve months after purchase order award. Estimated start and completion dates of all work is April 2024 and April 2025, respectively. Options: There are no options included in this contract. Range of estimated A&E price: Under simplified acquisition threshold (SAT), under $250,000. Subcontracting Plan: Not required. This contract is subject to the Service Contract Labor Standards and the current Service Contract Act Wage Decision (SCA WD) for the location of work has been attached. The SCA WD for the awardee's home office will be applicable and included at award. All interested vendors are required to be registered in sam.gov with a valid Commercial and Government Entity Program (CAGE) code. 2. PROJECT INFORMATION. A-E services shall include pavement inspection utilizing PAVER Version 7.1 or higher located at Fort Campbell, Kentucky. Work shall be accomplished in accordance with ASTM D6433 (20 or later) with exception to the sampling rate as identified in the Scope of Work (see attachments). Reference the Scope of Work for additional information regarding qualifications of personnel, coordination, permitting, field surveying, scheduling, submittals, government ownership, antiterrorism and security provisions, major requirements, modeling, analysis, 10-year working analysis, project development, meetings, ISR reporting, draft and final reporting, quality assurance, deliverables, and points of contact. 3. SELECTION CRITERIA: The selection criteria for this particular project are listed below in descending order of importance. a. Specialized Experience and Technical Competence: Submittals shall demonstrate the specialized experience and technical competence to execute the types of projects and activities as indicated above in paragraph 2, PROJECT INFORMATION. Experience implementing the PAVER Pavement Management System using the PAVER software version 6 or newer (PAVER 7 experience is preferred) and manual pavement distress data collection. Submit no more than four (4) examples of PAVER implementation projects using the PAVER software and pavement management system and manual distress data collection. Example projects should be submitted for roads and parking only. PAVER implementation experience on Army or Air Force installations is desirable but not essential. Only relatable experience that has occurred in the last five years should be included in the submittal. Project examples submitted should be of completed projects. All projects cited shall identify start/complete dates, project size (pavement area, cost and scope) and tasks performed. In addition to the example projects above, include a list (SF 330, Part I, Section H) of any other PAVER implementations using manual pavement distress data collection completed within the last five years including location, customer, pavement type (roads, parking areas, airfields, etc.) and area of pavement inspected. (SF 330, Part I, Section F) b. Professional Qualifications: Firms shall demonstrate professional personnel qualifications and specialized experience for key disciplines. Evaluation of professional qualifications will consider education, training, relevant experience and longevity with the firm. Experience working on applicable Army and Air Force projects is desirable and should be identified. (SF 330, Part I, Sections E & G). Provide resumes for a minimum of one (1) project manager (team leader), Project managers should be a U.S. registered Professional Engineer and have at least five (5) years of experience implementing the PAVER pavement management system. Provide resumes for a minimum of two (2) civil engineers. Civil Engineers should have a minimum of three (3) years of experience implementing the PAVER pavement management system. Civil engineers should have a thorough knowledge of the PAVER software and PAVER pavement management system and should have several years of experience identifying pavement distresses in accordance with ASTM D6433. Experience creating PCI and M&R family models, performing condition analysis, and performing M&R work planning should be indicated. Civil Engineers should be a U.S. registered Professional Engineer. List recent PAVER software training attended. Provide resumes for a minimum of two (2) Engineering Technicians. Engineering Technicians should have at least three (3) years of experience implementing the PAVER pavement management system. Engineer Technicians should have several years of experience identifying pavement distresses in accordance with ASTM D6433. Knowledge and experience using the PAVER software is desirable. Experience creating PCI and M&R family models, performing condition analysis, and performing M&R work planning should be indicated. List recent PAVER software training attended. Provide resume for a minimum of one (1) GIS Technician. GIS Technician should have at least one (1) year of experience creating/updating PAVER GIS network shapefiles. c. Past Performance. Past performance on DoD and other contracts with respect to the quality of work and compliance with performance schedules, as determined by CPARS and other sources. Submit entire CPARS evaluations, not summaries of ratings. Provide CPARS for the 4 projects identified in section I only. Provide PPQ in the event that CPARS does not exist. Firms which choose to use the PPQ may obtain a PPQ standard form by submitting a request to the below referenced POC via email. d. Proposed Management Plan. A proposed Management Plan shall be presented that includes an organization chart (reference SF330, Part I, Section D) and addresses team organization (reference SF330, Part I, Section C), any anticipated sub-contractors or entities to supplement the design team, quality control procedures, cost control, coordination of in-house disciplines and consultants required to meet work capacity. Organizational chart should clearly indicate available inspection teams. The SF 330 shall clearly indicate the primary office where the work will be performed and the staffing at that office. (SF 330, Part I, Section H, Item 2). 4. SUBMISSION REQUIREMENTS: Interested firms having the capabilities to perform this work must submit electronically one (1) copy of the SF 330 Part I, and one (1) copy of SF 330 Part II for the prime firm and all consultants/subcontractors, to the following recipients with subject line - Fort Campbell PAVER Synopsis Response not later than 2:00 PM Central Standard Time (CST) on the response date indicated in this announcement: Brandon Landis, brandon.p.landis@usace.army.mil Amanda Eaton, amanda.e.eaton@usace.army.mil For file sizes greater than 20 megabytes (MB) the firm shall break the file into smaller files sent via separate emails with each email marked to identify which number the email is relative to the total number of emails submitted (i.e. - Email 1 of 2). Once all emails submitted have been received the Government will confirm receipt via responsive email. Regulation requires that the Selection Board not consider any submittals received after the specified time and date. Late proposal rules in FAR 15.208 will be followed for submittals received after 2:00pm Central time on the closing date specified in this announcement. The SF 330, 3/2013 edition, must be used, and may be obtained from the following web site: http://www.gsa.gov/portal/forms/download/116486. Include DUNS number and CAGE code in SF330 Part I, Section B, Block 5. Additionally, the DUNS number and CAGE code should be identified in SF 330 Part I, Section C, Block 9, for EACH TEAM MEMBER. The submittal shall have a page limit of 50 pages (total of 50 pages allowed for complete copy of the submittal, ALL-INCLUSIVE). The selection board will not evaluate beyond 50 pages. A page is one side of a sheet. Blank sheets/Tabs separating the sections within the SF 330 will not count against the maximum page count. All fonts shall be at least 10 pitch or larger and have text of Arial, Times New Roman, or Calibri. Pages shall be 8-1/2 inches by 11 inches. Margins should be no less than 1 (right, left, top, and bottom). An SF 330 Part II is required for each branch office of the prime firm and any consultants/subcontractors that will have a key role in the proposed contract (i.e. a Part II is required for all entities identified in SF 330 Part I, Section C of the submittal). Cover letters, company literature and extraneous materials are not desired and will not be considered. Sections E and G of SF 330 Part I must include only individuals proposed to perform the anticipated work, including all consultants/subcontractors. In SF 330 Part I, Section G, Block 26, along with the name, include the firm with which the person is associated. A maximum of four (4) projects including the prime and consultants/subcontractors will be reviewed for SF 330 Part I, Section F. If more than 4 projects are submitted, only the first 4 projects will be evaluated. Use no more than two (2) pages per project. When listing projects in SF 330 Part 1, Section F, an Indefinite Delivery Contract (IDC) with multiple Task Orders as examples is not considered a project. A task order executed under an IDC contract is a project. Past Performance evaluations (CPARS/ACASS, PPQ - reference Paragraph 3.d. above) shall be submitted for each project provided in SF 330, Part I, Section F. SF 330, Part I, Section H (Additional Information) shall contain the following information. SF 330, Part I, Section H (Additional Information) shall contain the information in paragraph 3.d above regarding Management Plan. Joint ventures shall submit the following additional documentation of the evidence of a joint venture entity: 1) Firms shall provide a copy of a legally binding joint venture agreement, and 2) Identification of the party who can legally bind the joint venture. A draft solicitation is provided with this announcement. The purpose of this draft solicitation is for industry to be able to review the provisions, clauses, terms, and conditions. This is not a request for proposal. A price proposal is not requested with this announcement. The Corps will review contractor qualifications and select the most highly qualified firm. That firm will receive the solicitation and a proposal will be requested and negotiated with that firm. ALL QUESTIONS SHALL BE SUBMITTED VIA THE BIDDER INQUIRY PORTAL in ProjNet at http://www.projnet.org/projnet. Questions should be submitted no later than 25 March 2024 at 2:00 p.m. Central Time to allow time for a response. On this date and time the portal will be closed. For questions, no other means of communication, e-mail, fax, or telephone will be accepted. To submit and review inquiry items, prospective vendors will need to use the Bidder Inquiry Key presented below and follow the instructions listed below. A prospective vendor who submits a comment/question will receive an acknowledgement of their comment/question via email, followed by an answer to the comment/question after it has been processed by our team. All timely questions and approved answers will be made available through ProjNet. To submit and review inquiries, firms will need to be current registered users of the ProjNet system. Registration for ProjNet Bidder Inquiry Access (If you are already registered, go to Entering Bidder Inquiries in ProjNet Bidder Inquiry System below.) 1. From the ProjNet home page link above, click on Quick Add on the upper right side of the screen. 2. Identify the Agency. This should be marked as USACE. 3. Key. Enter the Bidder Inquiry Key listed below. 4. Email. Enter the email address you would like to use for communication. 5. Click Continue. A page will then open saying that a user account was not found and will ask you to create one using the provided form. 6. Enter your First Name, Last Name, Company, City, State, Phone, Email, Secret Question, Secret Answer, and Time Zone. Make sure to remember your Secret Question and Answer as they will be used from this point on to access the ProjNet system. 7. Click Add User. Once this is completed you are now registered within ProjNet and are currently logged into the system. Entering Bidder Inquiries in ProjNet Bidder Inquiry System 1. For future access to ProjNet, you will not be emailed any type of password. You will utilize your Secret Question and Secret Answer to log in. 2. From the ProjNet home page link above, click on Quick Add on the upper right side of the screen. 3. Identify the Agency. This should be marked as USACE. 4. Key. Enter the Bidder Inquiry Key listed below. 5. Email. Enter the email address you used to register previously in ProjNet. 6. Click Continue. A page will then open asking you to enter the answer to your Secret Question. 7. Enter your Secret Answer and click Login. Once this is completed you are now logged into the system. 8. Follow online screen instructions to enter specific bidder inquiries for the project. The Solicitation Number is: W9128F-24-R-0017 The Bidder Inquiry Key is: Q5EMAR-RHTX9Q Firms are requested to review the Bidder Inquiry Portal for previous questions and responses, prior to submission of a new inquiry in the Portal. Caution: Any inquiry submitted and answered within this system will be accessible to view by all interested firms on this solicitation. The call center for the ProjNet operates weekdays from 8 AM to 5 PM U.S. Central Time Zone. The telephone number is 1-800-428-HELP. 5. PLACE OF CONTRACT PERFORMANCE: As noted above Service Contract Act Wage Decisions will be applicable to both the project site, Fort Campbell, Kentucky, and the awardee's home office (this wage decision will be provided at award).

More opportunities from Department Of Defense → W071 Endist Omaha

Same awarding agency

NAICS: 237990
New
Federal
LOWER BRULE NORTH SHORELINE STABILIZATION AND ECOSYSTEM RESTORATION, ELEMENT 2
Solicitation # W9128F27BA007
The USACE Omaha District intends to award a contract for the Lower Brule North Shoreline Stabilization and Ecosystem Restoration, Element 2, located in Big Bend, Lower Brule, South Dakota. This project is a 100 percent Small Business Set-Aside under NAICS code 237990, with estimated construction costs ranging from 10 million to 25 million dollars. The scope of work involves the construction of a 100-foot-wide riparian planting bench, a gravel maintenance path, and the creation of a 200-by-1,500-foot island in Reach 4 of the lake. This island will be planted with cottonwood trees and culturally significant vegetation, protected by a riprap revetment to prevent erosion from wind, waves, and ice. These efforts are expected to create approximately 32 acres of riparian habitat and 5.17 acres of emergent wetland. The government plans to issue the Invitation for Bid on approximately October 6, 2026, with a closing date around November 10, 2026, and a scheduled site visit on October 28, 2026. The selected contractor must complete the work within 450 days of receiving the Notice to Proceed, and the contract will include provisions for liquidated damages and requirements for both performance and payment bonds. Bids must be submitted through the Procurement Integrated Enterprise Environment Solicitation Module, and all offerors must maintain an active and verified account in the System for Award Management.
Other Heavy and Civil Engineering Construction

POSTED

4 days ago

DEADLINE

N/A
View Details
NAICS: 237990
New
Federal
Construct Interim Remedial Action (IRA) for the Nelson Tunnel Superfund Site
Solicitation # W9128F27RA056
The USACE Omaha District intends to issue Request for Proposal W9128F27RA056 in November 2026, with a planned proposal due date in January 2027. This unrestricted solicitation, open to both small and large businesses, seeks construction services for the Interim Remedial Action at the Nelson Tunnel Superfund Site located near Creede, Colorado. The project, estimated between 15 million and 30 million dollars, aims to prevent the uncontrolled release of mine-impacted water from an abandoned underground hard rock mine. The scope of work includes the installation of a new bypass adit south of the Nelson Tunnel, rehabilitation of the tunnel from the bypass connection to the bulkhead location, the installation of a flow control bulkhead within the Nelson Tunnel, and the construction of an accessible bulkhead flow control structure in the Commodore 5 level. The contract will be awarded based on a best-value approach, evaluating technical merit and price. Technical evaluation factors include project management approach and schedule, past performance, key personnel, and small business participation, with technical factors rated adjectivally and price assessed for reasonableness and realism. Performance is expected to begin within 10 days of the Notice to Proceed and must be completed within a duration not exceeding 655 days. Interested parties must be registered in SAM.gov with NAICS code 237990 and registered in the Procurement Integrated Enterprise Environment (PIEE) as a Proposal Manager to receive documents and submit proposals. Site visits are subject to safety briefings and specific equipment requirements for underground entry.
Other Heavy and Civil Engineering Construction

POSTED

4 days ago

DEADLINE

in about 1 month
View Details
NAICS: 238220
New
Federal
Cooling Water System Repair and Reliability Project
Solicitation # W9128F26XICGB
The U.S. Army Corps of Engineers Omaha District is seeking capability statements for the Cooling Water System Repair and Reliability Project at Cavalier Space Force Station, ND. This project, estimated between 50 million and 70 million dollars, involves the comprehensive rehabilitation and modernization of a large-scale industrial cooling water system. The scope of work includes installing new fluid coolers, pumps, distribution loops, and a redundant heat exchanger arrangement, as well as the demolition and replacement of 24-inch piping. Critical requirements include maintaining full operational continuity of the system throughout construction to support national defense missions, adhering to HEMP requirements, and performing ACM abatement. The government intends to utilize a Progressive Design-Build approach via an Other Transaction Authority agreement under 10 U.S.C. 2808a, which operates outside the Federal Acquisition Regulation. Selection will be based on qualifications rather than price, focusing on team composition and past relevant experience. The anticipated schedule begins with design in the second quarter of fiscal year 2027, followed by construction in the fourth quarter of the same year. Interested firms must be registered in SAM.gov, capable of bonding at least 70 million dollars for a single project, and compliant with Cybersecurity Maturity Model Certification Level 1.
Plumbing, Heating, and Air-Conditioning Contractors

POSTED

4 days ago

DEADLINE

in 6 days
View Details
NAICS: 238990
Federal
GARRISON TRASH RACK MODIFICATION CRANE RENTAL
Solicitation # W9128F26QA099
Solicitation W9128F26QA099 is a firm-fixed-price service contract issued by the U.S. Army Corps of Engineers, Omaha District, for the rental of a crane and a qualified operator at the Garrison Dam near Riverdale, North Dakota. The primary objective is to support the modification of intake trash racks to conserve cool waters for fishery missions during drought conditions. The contractor is responsible for providing all equipment, tools, vehicles, and supervision necessary to lift and lower trash racks weighing between 30,000 and 33,000 pounds, with the capacity to overcome friction factors up to 41,000 pounds. The period of performance is scheduled from October 30, 2026, through June 30, 2027. This procurement is a total set-aside for Women-Owned Small Businesses and Economically Disadvantaged Women-Owned Small Businesses under NAICS 238990. Award will be based on the most advantageous offer, evaluating price alongside technical information and past performance, including three project examples from the last two years. Key compliance requirements include adherence to EM 385-1-1 safety standards, the submission of a site-specific Accident Prevention Plan and Lift Plan, and compliance with Service Contract Act wage determinations for North Dakota. Following Amendment 0001, the closing date for the submission of offers has been extended to October 23, 2026, at 2:00 PM.
All Other Specialty Trade Contractors

POSTED

7 days ago

DEADLINE

in 3 days
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS