Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, September 16 at 2:00 PM EDT

Register Free →

This Solicitation opportunity from Department Of Defense was posted on May 11, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

SLEEVE, WRAP-AROUND,

Closed
SPE2DS-26-T-067AFederal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 339113
New
Federal
STERIS InnoWave Irrigator
Solicitation # 36C24126Q0765
The Department of Veterans Affairs, through the Network Contracting Office 01, is soliciting quotes for the procurement of one STERIS InnoWave PCF Sonic Irrigator for the Sterile Processing Services Department at the Manchester VA Medical Center in New Hampshire. This combined synopsis and solicitation is a small business set-aside under NAICS code 339113. The requirement is justified as a single-source procurement from Steris Corporation due to compatibility with existing workflows and infrastructure, though the equipment may be acquired through small business distributors. The scope of work includes the delivery, installation, and operational verification of the unit, as well as the deinstallation and disposal of the existing inoperable ultrasonic cleaner and all associated packaging materials. The contractor must provide onsite operational training for staff covering maintenance, safety, and troubleshooting. Delivery is required no later than 45 days after receipt of order, with full installation and verification completed within 90 calendar days of the award. Award decisions will be based on price, past performance, and speed of delivery. Interested offerors must submit their quotes by September 21, 2026, including their Unique Entity Identifier and a statement of agreement with the solicitation terms. All services and equipment must be delivered and accepted at the Manchester VA Medical Center.
241-NETWORK Contract Office 01 (36C241)

POSTED

about 23 hours ago

DEADLINE

in 9 days

AI Contract Overview

Show more

The contract solicitation SPE2DS-26-T-067A seeks the procurement of 1 package of five pairs of disposable, non-sterile, wrap-around pneumatic compression sleeves designed for thigh-length use with a small size fit. Each sleeve contains three bladders to deliver circumferential, sequential, and gradient compression aimed at promoting deep vein clearance without distal blood trapping. The product is anatomically designed with adjustable closure for patient customization and must comply with strict medical and packaging standards. The item has a non-extendable 60-month shelf life under Type I Code S classification and must be packaged and marked in accordance with the Medical Marking Standard No. 1, superseding MIL-STD-129, while adhering to MIL-STD-2073-1E for packaging integrity. All shipments must meet DLA packaging requirements, and labeling must conform to Hazard Communication Standard 29 CFR 1910.1200. Delivery is required at destination within 20 days of order, under FOB Destination terms, with government inspection and acceptance occurring upon receipt. The item is identified by NSN 6515-01-565-1340 and is being procured under a simplified acquisition with no specified contract type, allowing offerors to propose alternative contract structures under deviation 2026-00038. The solicitation mandates compliance with comprehensive cybersecurity and supply chain integrity requirements, including implementation of NIST SP 800-171, self-reporting of cybersecurity assessments through the Supplier Performance Risk System at Basic, Medium, or High confidence levels, and adherence to prohibitions on covered defense telecommunications equipment. Offerors must disclose unique entity identifiers, CAGE codes, and socioeconomic status including small business, HUBZone, WOSB, or SDVOSB designations, and submit representations in accordance with current SAM data. Contractors are required to inform employees of whistleblower rights, safeguard covered defense information, and report any cyber incidents per DFARS clauses. Hazardous materials, if used, must be labeled and documented per federal statutes and submitted for review prior to award. Proposals must be submitted electronically via DIBBS by the deadline of May 18, 2026, with invoice processing mandated through WAWF. Pricing details are not provided in the solicitation, and award will be made based on technical acceptability and price, with likely use of a lowest price technically acceptable

General Info

Procurement of adjustable, disposable pneumatic compression sleeves, 60-month shelf life, 20-day delivery.

Agency

Department Of Defense → MEDICAL SUPPLY CHAIN MD SURG FSFView Agency

NAICS

339113 - Surgical Appliance and Supplies ManufacturingView NAICS

Place of Performance

USA

Set-Aside

NONE

Documents

(1)

RFQ SPE2DS-26-T-067A Medical Supply Chain

PDFrfq

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

PhaseClosed
Posted

Solicitation

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → MEDICAL SUPPLY CHAIN MD SURG FSF
Contacts1 person available
OfficeUSA
Organization / Agency
Department Of Defense → MEDICAL SUPPLY CHAIN MD SURG FSF
View Agency Profile
Office AddressUSA

Full Description

Show more
SLEEVE,WRAP-AROUND,
SLEEVE, WRAP-AROUND, PNEUMATIC
THE COMPRESSION SLEEVE CONTAINS THREE BLADDERS
TO DELIVER CIRCUMFERENTIAL, SEQUENTIAL AND GRADIENT
COMPRESSION TO ENSURE CLEARANCE OF THE DEEP VEINS
WITHOUT THE RISK OF DISTAL BLOOD TRAPPING; THE SLEEVE
IS ANATOMICALLY DESIGNED WITH ADJUSTABLE SLEEVE
CLOSURE OFFERING A CUSTOMIZED FIT FOR EACH
PATIENT; DISPOSABLE; NON-STERILE; ADJ.; SZ: SMALL<(>,<)>
THIGH LENGTH; PACKAGED IN PAIRS/5 PR. PER PKG.
UNIT OF ISSUE: PACKAGE / 5PR,, ,,
..
RS023: Shelf-life requirement RS001 for a TYPE I (CODE S) item with a shelf life of 60 months (non-extendable) applies to this item.
.. RA001: THIS DOCUMENT INCORPORATES TECHNICAL AND/OR QUALITY REQUIREMENTS (IDENTIFIED BY AN 'R' OR AN 'I' NUMBER) SET FORTH IN FULL TEXT IN THE DLA MASTER LIST OF TECHNICAL AND QUALITY REQUIREMENTS FOUND ON THE WEB AT:
http://www.dla.mil/HQ/Acquisition/Offers/eProcurement.aspx http://www.dla.mil/HQ/Acquisition/Offers/eProcurement.aspx
FOR SIMPLIFIED ACQUISITIONS, THE REVISION OF THE MASTER IN EFFECT ON THE SOLICITATION ISSUE DATE OR THE AWARD DATE CONTROLS. FOR LARGE ACQUISITIONS, THE REVISION OF THE MASTER IN EFFECT ON THE RFP ISSUE DATE APPLIES UNLESS A SOLICITATION AMENDMENT INCORPORATES A FOLLOW-ON REVISION, IN WHICH CASE THE AMENDMENT DATE CONTROLS.
..
RD003, COVERED DEFENSE INFORMATION POTENTIALLY APPLIES
..
RP001: DLA PACKAGING REQUIREMENTS FOR PROCUREMENT
..
RQ011: REMOVAL OF GOVERNMENT IDENTIFICATION FROM NON-ACCEPTED SUPPLIES
..
BIDDER: PLEASE SPECIFY SOURCE AND PART
NUMBER BEING SUPPLIED.
ADEQUATE DATA FOR THE NSN/Part Number: 6515-01-565-1340 Quantity: 1 PG Purchase Request: 7016726852QTY: 1 Delivery: 20 days ADO

More opportunities from Department Of Defense → MEDICAL SUPPLY CHAIN MD SURG FSF

Same awarding agency

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 650+ contractors already using CLEATUS