Sodium Iodide Detector for Thyroid Counting

Active
75F40126Q00375Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

The Food and Drug Administration is seeking quotations for a firm-fixed-price purchase order under solicitation 75F40126Q00375. The contract involves the procurement of a 3x3 LED temperature stabilized Sodium Iodide probe and a digital tube based multichannel analyzer with USB and Ethernet output. Both components must be seamlessly compatible with Apex InVivo Software and the Mirion Osprey Multichannel Digital Analyzer. The estimated value of the contract is 20,000 dollars, with a required delivery date of September 15, 2026. The equipment must meet strict technical specifications, including an energy range of 30 keV to 3 MeV for the detector and a 14-bit 20 MHz sampling ADC for the analyzer. The detector must weigh less than 6 lbs and have a diameter under 3.5 inches. The contractor is required to provide a minimum 12-month warranty covering all parts and labor starting from the date of government acceptance. This opportunity is designated as a total set-aside for small businesses.

General Info

FDA seeks small business quotes for LED probe and analyzer by September 2026.

Agency

Department Of Health And Human Services → FDA Office Of Acquisitions And Grants ServicesView Agency

NAICS

334516 - Analytical Laboratory Instrument ManufacturingView NAICS

Place of Performance

Winchester, MA, 01890, USA

Set-Aside

SBA

Documents

(1)

SOW.pdf

PDF

AI Contract Breakdown

Uniform Contract Format

What is UCF?

Uniform Contract Format (UCF) uses AI to break down any contract into standardized sections—scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseCombined Synopsis
Posted

Combined Synopsis

Response Deadline

Submission deadline

Response Deadline

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of Health And Human Services → FDA Office Of Acquisitions And Grants Services
Contacts1 person available
OfficeRockville, MD, 20857, USA
Organization / Agency
Department Of Health And Human Services → FDA Office Of Acquisitions And Grants Services
View Agency Profile
Office AddressRockville, MD, 20857, USA

Full Description

Show more

This is a combined synopsis/solicitation for commercial products and commercial services prepared in accordance with the format in FAR 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested, and a written solicitation will not be issued separately.


Solicitation No.: 75F40126Q00375 
Contracting Activity: Food and Drug Administration (FDA)
Office/Center: Office of the Commissioner (OC)
Acquisition Type: Commercial Product
Solicitation Type: Request for Quotation (RFQ)
Contract Type: Firm-Fixed-Price Purchase Order
Estimated Value: $20,000
Required Delivery: September 15, 2026


DELIVERABLE:


1. 3X3 LED Temperature stabilized Sodium Iodide Probe compatible with Mirion Osprey Multi Channel Analyzer


Delivery Date: 9/15/2026



2. Digital Tube Based Multichannel Analyzer with USB and Ethernet output


Delivery Date: 09/15/2026


Salient Characteristics


The equipment offered shall meet or exceed all requirements listed below.


Detector Characteristics


  • 3”X 3” NaI(Tl) LED Stabilized Scintillation Detector
  • Energy Range 30 keV to 3 MeV
  • Resolution >7%
  • Available with generic efficiency characterization
  • OPERATING HUMIDITY – 85% non-condensing
  • OPERATING TEMPERATURE – -20 to +50 °C (-4 to 122 °F).
  • Must be compatible and seamlessly compatible with Apex InVivo Software and Mirion Osprey Multichannel Digital Analyzer
  • Diameter less than 3.5”
  • Weight < 6 lbs


Multi-Channel Digital Analyzer Characteristics


  • Includes HVPS, Preamplifier and Digital MCA
  • Gain Coarse Gain: x1, x2, x4, x8 software programmable
  • Fine Gain: x1 – x5 software programmable
  • Total Gain: Product of Fine Gain and Coarse Gain, x1 – x40
  • ADC: ADC 14-Bit 20 MHz Sampling
  • ULD/LLD ULD: 0% to 100% of Full Scale software programmable
  • LLD: 0% to 100% of Full Scale software programmable
  • Detector Voltage: HVPS 0 to +1300 V dc: 100 V/s ramping on power up and down
  • Shaping DSP Based Trapezoidal shaping filter operating at 80 MHz
  • Rise Time: 0.2 μs – 5 μs in 200 ns steps. Default: 1 μs for NaI probe
  • Flat Top: 0 to 3 μs in 100 ns steps. Default: 1 μs for NaI probe
  • Digital Spectrum Stabilization
  • Automatic Baseline Restore
  • Automatic Fast Discriminator threshold
  • Seamlessly compatible with Apex InVivo Software
  • USB 2.0 and Ethernet 10/100BaseTX Output
  • 14 pin and 8 pin PMT socket compatible
  • Diameter less than 3.5”
  • Weight < 6 lbs
  • ACQUISITION MODES
    • PHA PHA Channels: 256 to 2048 Channels, supports two memory groups of up to 2048 channels each
    • Preset: ROI Counts (Integral), Real or Live Time timers
    • Real and Live Time Resolution: 0.01 s
    • Preset Time: 0 to >4 x 107 s
    • Control: Internal or External Start/Stop control
    • LTC accuracy: 5% (3% typical) up to 50 kcps
  • MCS
    • MCS Dwell range: 1 μs to 999 seconds in 1 μs steps
    • Sweep range: 1 to 232 -1
    • Preset Sweep Counter: 0 to 232 -1 Sweeps (0 implies "Forever")
    • MCS input selection: PHA ROI, external TTL or Fast Discriminator
    • Dwell selection: internal or external
    • MCS Channels: 256 to 2048 Channels, supports two memory groups of up to 2048 channels each
  • 8192 Channels Configurable as two groups of 2048, 1024, 512 or 256 channels for PHA and MCS with 32 bits per channel
  • Integral Non-linearity: ±0.025% of full scale over the top 99% of the selected range
  • Differential Non-linearity: ±1% over the top 99% of the range including the effects from integral non-linearity
  • Gain Drift: <75 ppm/°C after 15 minutes of operation
  • Incoming Count Rate (ICR): >250 K cps ICR if not limited by probe/detector
  • Short Circuit Protection
  • High Voltage Power Supply
    • OUTPUT: 0-1300 V at 50 μA max
    • RIPPLE: 1 mV — ACCURACY: 3% Full Scale
    • SETTING RESOLUTION: 14-bit (1/16 384)


WARRANTY AND SUPPORT


The Contractor shall provide a minimum 12-calendar-month warranty covering all parts and labor.


The warranty period shall begin on the date of formal Government acceptance.


Warranty service shall include repair or replacement of defective components necessary to maintain operation of the delivered system.



Review the attached document for complete description of the requirement.


Similar Contracts

Same NAICS industry code

More opportunities from Department Of Health And Human Services → FDA Office Of Acquisitions And Grants Services

Same awarding agency