Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of The Navy was posted on October 1, 2025. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Sources Sought for LCAC Rugged Network Core Switch Device

Closed
N61331-26-SN-Q03Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

AI Contract Overview

Show more

The Naval Surface Warfare Center, Panama City Division, is conducting a market survey to identify potential sources capable of providing a commercial off-the-shelf rugged network core switch device for the Landing Craft Air Cushion (LCAC) program upgrade. The desired device must feature at least 24 Ethernet ports supporting 1Gb/s speeds, with additional capabilities such as non-blocking switching, VLAN support, multicast management, security features including 802.1X authentication, and advanced QoS functionalities. The switch should be rugged, suitable for harsh environments, with environmental testing compliance per MIL-STD-461F and MIL-STD-810F, including operation in extreme temperatures, humidity, vibration, and shock conditions. Physical specifications include rack-mountability, conduction cooling, corrosion-resistant construction, and low weight, with power input ranging from 18-32 VDC and protections against reverse polarity and over-current. Vendors are asked to provide detailed responses addressing each key parameter, along with supporting documentation, cost estimates, reliability data, lifecycle information, lead times, and diagnostics capabilities. The responses, due by October 16, 2025, can be submitted electronically or via paper, with no formal format required. This RFI is solely for market research and does not constitute a solicitation or guarantee procurement. Should the government proceed to a formal solicitation, it will be announced on SAM.gov, with NAICS code 334511 applying, and the standard size limit of 750 employees. The effort aims to identify suitable commercial solutions to meet the program's rugged networking needs for naval surface operations.

General Info

Naval Center seeks rugged 24-port 1Gb/s network switches for LCAC upgrade; responses by Oct 16, 2025.

Agency

Department Of The Navy → Naval Surface Warfare Center

NAICS

334511 - Search, Detection, Navigation, Guidance, Aeronautical, and Nautical System and Instrument Manufacturing

Place of Performance

Panama City Beach, FL, 32407, USA

Set-Aside

NONE

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of The Navy → Naval Surface Warfare Center
Contacts2 people available
OfficePANAMA CITY BEACH, FL, 32407-7001, USA
Organization / Agency
Department Of The Navy → Naval Surface Warfare Center
Office AddressPANAMA CITY BEACH, FL, 32407-7001, USA
Contacts
Trivia Massaline
Frances J. Negrón

Full Description

Show more

Request for LCAC Rugged Network Core Switch Device


The Naval Surface Warfare Center, Panama City Division (NSWCPCD) is conducting a survey of potential sources for the Landing Craft Air Cushion (LCAC) program. NSWCPCD is seeking sources for a commercial off-the-shelf (COTS) Rugged Network Core Switch Device for a system upgrade effort.


This is a REQUEST FOR INFORMATION (RFI) for a Rugged Network Core Switch Device for the Landing Craft Air Cushion (LCAC).  THIS IS NOT A REQUEST FOR PROPOSALS. 


Key Parameters include but not limited to: 


Features/Capabilities:


  1. Ports and Physical Interface:
    1. Twenty-four (24) Ethernet ports (threshold-minimum)
    2. 1Gb/s speed for all Ethernet ports (threshold-minimum)
    3. 10/100/1000BaseTX (or faster) port for local maintenance access (goal)
  2. Performance and Switching: (goal)
    1. Provides non-blocking switching capabilities
    2. Supports store-and-forward switching
    3. Switching capacity of twice the cumulative bandwidth of all Ethernet ports
    4. Supports switch stacking
  3. Port Management: (goal)
    1. Supports individual port configuration, including speed, duplex, and flow control
    2. Supports port rate limiting
    3. Allows enabling and disabling of individual ports
    4. Provides the capability to mirror individual ports
    5. Supports port channeling
  4. VLAN Support:
    1. Supports port-based VLANs and private VLANs
  5. Multicast Management:
    1. Supports IGMP snooping.
  6. Security:
    1. Supports 802.1X port-based authentication.
    2. Supports MAC address filtering
    3. Supports RADIUS or TACACS+ authentication
    4. Supports port security features, including violation modes (shutdown, restrict, protect) and actions
    5. Employs DoS protection mechanisms
    6. Supports SNMPv3
  7. Quality of Service (QoS):
    1. Support for IEEE 802.1p CoS with 8 priority levels (0-7)
    2. Supports DSCP
    3. Permits configuration of QoS policies based on Layer 2-4 criteria
    4. Allows at least four egress queues per port
    5. Supports Strict Priority queuing
  8. Management and Monitoring:
    1. Supports SSH and SFTP for remote management and file transfer
    2. Accepts multiple configuration files for backup and restore
    3. Supports configuration change logging and rollback
    4. Provides real-time system health monitoring
    5. Supports port mirroring (SPAN/RSPAN)
    6. Compatible with diagnostic tools (ping, traceroute, cable diagnostics)
    7. Capable of generating downloadable system event logs
    8. Provides individual port status monitoring and statistics
  9. Environmental Monitoring (if applicable):
    1. Provides environmental monitoring (temperature, humidity)

Electrical:


  1. Input Power Voltage Range: 18-32 VDC (28 VDC nominal)
  2. Protection: Reverse Polarity and Over-current protection (threshold)

Physical:


  1. Cooling: Conduction cooling with no internal or external forced-air required

  1. Corrosion Resistance: All connectors, fasteners, and the chassis material inherently corrosion resistant or treated (for example, anodized, chemical-filmed, or coated) to resist corrosion  
  2. Mounting: 19” rack mounted
  3. Power-on Indicator: External indicator that indicates the unit is powered ON (goal)
  4. Dimensions:
    1. Height: 1.75” (goal) 1U
    2. Width: 19” (goal) rack mounted
  5. Weight:  <20 lbs (goal)
  6. Connectors: RJ45, mini DB9, or MIL-STD grade, threaded or bayonet style, circular connectors for external interfaces.  No special pinout mappings required.  Low connector count desired.  Connector(s) not limited to single interface. (goal)
  7. Grounding/Bonding: Provisions for grounding the chassis with a grounding screw/stud

Environment:


NOTE: Unit has been qualified for the following testing (goal):


  1. MIL-STD-461F Electromagnetic Interference (EMI), Navy surface ship applications:
    1. CE101
    2. CE102
    3. CS101
    4. CS106
    5. CS114
    6. CS116
    7. RE101
    8. RE102
    9. RS101
    10. RS103
  2. MIL-STD-810F tailored environmental specifications

  1. Low Temperature: -25°C, operational
  2. High Temperature +55°C, operational
  3. Humidity: 95%, non-condensing, operational
  4. Vibration: 10 to 2000 Hz, operational
  5. Shock: 10Hz@ 5Gs, 500Hz@40G’s, and 2000Hz@40 Gs, operational

Vendors shall provide the following information:


  1. Responses for each key parameter listed in this document, i.e. how the proposed solution meets each parameter listed in this document. 
  2. Relevant documentation (data sheets, user manuals, test reports, etc.).
  3. Under separate cover, provide unit cost with price breaks up to a quantity of 100.  Range with not-to-exceed estimate is acceptable.
  4. Available reliability data with associated application conditions and measuring methods.
  5. Anticipated life-cycle of the proposed solution, e.g. anticipated active production years with follow on support years for existing customers.
  6. Lead-time for delivering first four units and standard lead-times thereafter should a production contract be awarded.
  7. Return for repair process with minimum estimated service charge.
  8. Technology maturity or technology readiness level (TRL) as defined by the Defense Acquisition Guidebook (DAG), and use in DoD programs.
  9. Description of any onboard diagnostic and/or fault identification/isolation capability.

RESPONSES: Interested parties may provide electronic or paper submittals to be received by the Government by October 16, 2025.  There is no specific format or outline that submittals must follow.  Each response must reference the RFI title.  Contractors responding should indicate whether they are a small business (S), a small, disadvantaged business (SDB), 8(a), or large business (L). 


Telephone responses will not be honored.  Please email responses with any supporting attachments to contact@example.gov and contact@example.gov.  Paper submittals should be directed to NSWCPCD (Code 023), ATTN: Trivia Massaline, 110 Vernon Ave, Panama City, FL 32407-7001 and label with the Sources Sought number and title.


This is a Request for Information (RFI), a market survey for written information only.  THE SUBMISSION OF THIS INFORMATION IS FOR PLANNING PURPOSES ONLY AND IS NOT TO BE CONSTRUED AS A COMMITMENT BY THE GOVERNMENT TO PROCURE ANY ITEMS/SERVICES, NOR FOR THE GOVERNMENT TO PAY FOR THE INFORMATION RECEIVED.


In the event a solicitation is developed, it will be assigned a formal Request for Proposal (RFP) number, and the announcement will be published in SAM.gov. This announcement should not be construed as a commitment by the Government to issue a solicitation or ultimately award a contract. NAICS Code 334511 applies, Size Standard is 750 employees, FSC 2090.



Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS