Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Solicitation opportunity from Florida was posted on July 22, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

SRF Water System Upgrades

Closed
2026-04State & Local

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 237110
New
Morgans Branch Force Main and Pump Station Improvements
Solicitation # SRP-W-134-0290
The Morgans Branch Force Main and Pump Station Improvements project, solicitation number SRP-W-134-0290, is a construction contract for the City of Belmont, North Carolina, with a project estimate of $16,690,000. The scope of work involves the construction of 16,435 linear feet of new 20-inch ductile iron force main and comprehensive upgrades to the Morgans Branch Pumping Station. Key deliverables include the installation of a new wet well, valve vault, and associated appurtenances, as well as the demolition of existing pumps and piping. The project also encompasses the installation of new gravity sewers, manholes, and a fully operational pumping station equipped with mechanical and electrical systems, a generator, odor control equipment, and stormwater facilities. The contract will be awarded to the responsible bidder submitting the lowest responsive bid, with a substantial completion timeline of 560 calendar days. Bidders must provide a bid bond using form EJCDC C-430 and submit required MWBE documentation, including a Good Faith Efforts Form and Table A. The project is administered by Willis Engineers, who serve as the Owner's Representative. Payment is processed via Applications for Payment, with payments becoming due 30 days after presentation to the owner. Technical standards for the work include compliance with AWS D1.2 for welding, NEMA standards for motors, and ASTM C 1093 for masonry testing.
Don Moorhead Construction, Inc.

POSTED

about 8 hours ago

DEADLINE

in 13 days
NAICS: 237110
New
Main Wastewater Treatment Plant Secondary Reactors Rehabilitation Phase 2 in CA
Solicitation # main-wastewater-treatment-plant-secondary-reactors-rehabilitation-phase-2-ca
Garney Pacific, Inc. is seeking quotes from qualified subcontractors for the Main Wastewater Treatment Plant Secondary Reactors Rehabilitation Phase 2 project located in Oakland, California, for the East Bay Municipal Utility District. This solicitation is open to small businesses, including certified Veteran Owned, Service-Disabled Veteran Owned, Women-Owned, and HUBZone small businesses. The comprehensive scope of work involves the rehabilitation of covered and open concrete structures, the relining or replacement of steel and ductile iron pipes and supports, and the installation of valves and piping appurtenances. Additional requirements include the operation of a temporary 11 MGD pumped bypass, rehabilitation of reactor mixers and aerators, upgrades to motor control center components, and the installation of new instrumentation, electrical systems, and slide gates. Key deliverables for the project include lead abatement, metals fabrication, painting and coatings, concrete resurfacing, and the installation of FRP reinforcing systems and access hatches. All subcontractors are required to utilize union labor and must be prepared to provide a 100 percent Payment and Performance Bond from a US Treasury listed Surety Company, with bond premiums reimbursed by Garney Pacific. Interested parties must submit their quotes, including their bond rate and any redlines to standard subcontract forms, by November 17, 2026, at 2:00 PM PT.
Garney Pacific, Inc.

POSTED

about 8 hours ago

DEADLINE

in 21 days
NAICS: 237110
New
IEUA RP-5 Offsite Facilities Project No. EN19001.03 and Butterfield Lift Station Improvements Project No. EN26054
Solicitation # EN19001.03 / EN26054
Filanc is soliciting quotes for the IEUA RP-5 Offsite Facilities Project No. EN19001.03 and the Butterfield Lift Station Improvements Project No. EN26054 located in Chino and Chino Hills, California. The comprehensive scope of work involves significant wastewater infrastructure improvements, including the installation of approximately 6,200 linear feet of dual 14 to 16-inch diameter HDPE DR 11 pipelines from El Prado Road to Kimball Avenue. Additionally, the project requires the construction of a new Mountain Avenue Lift Station featuring a concrete wet well and submersible pumps, modifications to the RP-2 Lift Station to include an elevated electrical platform and standby generator, and the replacement of the motor control center, pumps, and motors at the Butterfield Lift Station while maintaining continuous operation. Filanc is seeking quotes across a wide array of trades, including SWPPP, survey, aggregates, demolition, fencing, paving, striping, precast concrete, rebar, masonry, metals, coatings, signage, process equipment, pre-engineered FRP enclosures, fire suppression, piping, valves, pipe supports, and electrical and instrumentation and control. This solicitation is open to small businesses, including SDB, WOSB, HUBZone, and VOSB certifications, with a strong emphasis on DBE participation. Bids are due by 2:00 PM on October 29, 2025. The primary point of contact for this opportunity is Julia Masaitis.
Filanc

POSTED

about 8 hours ago

DEADLINE

in about 17 hours

AI Contract Overview

Show more

The SRF Water System Upgrades project, solicitation number 2026-04, focuses on increasing service pressure to Magnolia Point through the replacement of two jockey pumps and three high service pumps. The base bid includes the installation of motor-operated butterfly valves to replace existing hydraulic control valves at Magnolia Point Loop Control Stations 1 and 2, as well as at the Harbor Road and Bonaventure elevated storage tanks. These upgrades are supported by necessary electrical and instrumentation improvements. Additional project scopes are available as additive alternates. Alternate 1 involves the construction of a 200,000-gallon ground storage tank with a conventional tray aerator to increase total storage capacity to 600,000 gallons. Alternate 2 includes the construction of two 10,000-gallon hydropneumatic tanks equipped with an air compressor. This solicitation is issued by the Florida Water/Wastewater agency in Green Cove Springs, with a response deadline of September 15, 2026.

General Info

SRF Water System Upgrades: pump and valve replacements with optional storage tank additions.

Documents

4

202604 SRF Water System Upgrades RFP

PDF, High priority: read this first17 pages · rfp
High

Bid Table – Water System Upgrades – Green Cove Springs

PDF, High priority: read this first1 page · bid-form
High

Green Cove Springs Water System Upgrades - Bid Set Plans

PDF, High priority: read this first57 pages · sow
High

Water System Upgrades Bid Set, Project No. M890563.000

PDF, High priority: read this first731 pages · bid-set
High

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

PhaseClosed
Posted

Solicitation

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyFlorida → Water / Wastewater
Contacts1 person available
OfficeGreen Cove Springs, FL, 32043, USA
Organization / AgencyFlorida → Water / Wastewater
Office AddressGreen Cove Springs, FL, 32043, USA
Contacts
Jason LaurenzaEngineering Technician

Interested Companies (59)

Hubbard ConstructionWinter Park, FL
U.S. Water Services Corporation DBA Rocha ControlsTampa, FL
Wind River EnvironmentalOrlando, FL

See All 59 Interested Companies

Start a free trial to view all interested companies, their contact details, and full contractor profiles.

Start Free Trial

Full Description

Show more
BASE BID - Remove and replace two Jockey and three High Service (HS) Pumps to increase available service pressure to Magnolia Point. Revised design points are summarized as follows: • Jockey Pumps: 400 gpm @ 196 ft (TDH) | 85 psig • HS Pumps: 1,200 gpm @ 196 ft (TDH) | 85 psig - Magnolia Point Loop Control Station 1 and Station 2 valving modifications to remove existing hydraulic control valves with motor-operated butterfly valves. - Harbor Road Elevated Storage Tank (EST) hydraulic altitude valve removal and replacement with motor operated butterfly valves. - Associated electrical and instrumentation improvements. - Bonaventure EST Improvements: Hydraulic altitude valve removal and replacement with motoroperated butterfly valves. ADDITIVE ALTERNATE 1 - Harbor Road WTP and Magnolia Point Control Valve Improvements: Construct 200,000-gallon Ground Storage Tank 3 (GST 3) with conventional tray aerator to increase the storage capacity to 600,000 gallons. ADDITIVE ALTERNATE 2 - Construct two 10,000-gallon hydropneumatic tanks (Hydro Tanks) with air compressor.

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS