This Solicitation opportunity from Hawaii was posted on March 17, 2025. The submission period has ended. Browse the details below for market research, or find similar active opportunities.
The Hawaii Department of Defense is seeking a qualified vendor to modernize a total of seven tsunami sirens across multiple counties in Hawaii, including four in Honolulu County, two in Kaua’i County, and one on the Big Island. The project aims to upgrade or repair these critical warning systems to ensure their reliability and effectiveness in emergency situations. The contract, titled "Statewide Tsunami Siren Repair," has a budget range between $50,000 and $150,000 and is open for responses until April 14, 2025. The solicitation was posted on March 17, 2025, and the Hawaii Department of Defense will oversee the project, with Garret Garalde serving as the primary contact for inquiries. The work locations are specified in the Statement of Work, which includes aerial and street view references, emphasizing the importance of precise site assessments for successful modernization. Interested vendors can find additional details and submit their proposals through the Hawaii Electronic Procurement System.
HighAI Summary for Attachment 1 Group 1 - Siren Repair List: Technical specifications and repair requirements for Group 1 sirens, including specific locations (Wailua, Makaha, Dillingham Airfield) and required tasks such as installing solar panels, M27 marine batteries, and UV-HSO cabinets.
PDF
PDF, High priority: read this firstspecifications
HighAI Summary for Attachment 2 Group 2 - Siren Repair List: This document provides a detailed list of siren locations (KA103 and KA111) and the specific repair requirements for Group 2, including the installation of new solar panels, top mount brackets, M27 marine batteries, and driver testing/replacement.
PDF
PDF, High priority: read this firstspecifications
HighAI Summary for Attachment 3 Group 3 - Siren Repair List: This document is a technical attachment specifying repair requirements for Group 3 sirens, specifically detailing solar panel installation, bracket mounting, battery replacement, and driver testing for siren HA104 located in Hilo, HI.
PDF
PDF, High priority: read this first16 pages · general-conditions
HighAI Summary for Exhibit A General Conditions: This document titled 'Exhibit A General Conditions' outlines the standard contractual terms and conditions governing the relationship between the State and the Contractor. It includes sections on coordination of services, independent contractor status, personnel requirements, nondiscrimination, conflicts of interest, subcontracts, indemnification, payment procedures, contract modifications, confidentiality, audit rights, compliance with laws, and other essential contract provisions. The document is intended to ensure clear responsibilities, legal compliance, and proper contract administration. It serves as a foundational contract component for procurement agreements with the State, dated as the current version provided.
PDF
PDF, High priority: read this firstsow
HighAI Summary for Exhibit B Solar Power Installation and Operation Manual: This document is the Description, Installation, and Operation Manual for Solar Power Option Models PVS240W-24 and PVS240W-48. It includes safety messages, general description, features, ordering information, specifications, installation instructions, and wiring details. The manual emphasizes safety precautions for installation and service, specifying that only experienced electricians should perform electrical work. It provides detailed installation procedures for side pole and top-of-pole mounts, required tools, and solar regulator settings. The document also contains tables for ordering information, mounting specifications, recommended batteries, and switch settings. The manual is essential for proper installation, operation, and maintenance of the solar power system to ensure safety and functionality.
PDF
PDF, High priority: read this firstspecifications
HighAI Summary for Exhibit C Driver Connection - Siren Installation and Wiring Guide: This document, titled Exhibit C Driver Connection, provides detailed specifications and instructions for the installation and wiring of siren driver connections and modules. It includes diagrams and tables illustrating driver connections, wire colors, cable lengths, and module configurations for various siren models. The document also covers installation guidelines for mounting the siren on flat surfaces, installing optional top and side lights, and performing pre-operation checkout procedures. Safety warnings regarding hearing protection during testing are included. The version date is not specified, but the content is technical and critical for proper siren installation and operation.
PDF
PDF, High priority: read this firstsow
HighAI Summary for Exhibit D SAT CELL TESTING Procedure and Mounting Instructions: This document titled 'Exhibit D SAT CELL TESTING' provides detailed procedures and instructions for satellite and cellular antenna testing and mounting, specifically for the State of Hawaii. It includes a step-by-step contractor testing procedure requiring 24-hour notice to HI-EMA, general information on required materials, recording of DMR800 ISN numbers, mounting instructions for the DMR800D satellite terminal and cellular antenna, application of waterproof sealing compounds, and cable connection and routing guidelines. The document is versioned as Rev. 2/23/12 and emphasizes proper handling to avoid damage, environmental protection measures, and specific mounting orientations for optimal satellite signal reception.
PDF
PDF, High priority: read this firstspecifications
HighAI Summary for Exhibit E Modulator Speaker Wiring Diagram: Technical specifications and wiring diagrams for modulator speaker arrays, detailing driver orientation and wire counts/usage for various module models (MOD1004B through MOD8032B).
PDF
PDF, High priority: read this firstspecifications
HighAI Summary for Exhibit G Control Cabinet Installation: Technical specification document regarding the installation of control cabinets, specifically detailing the replacement of 1 1/4 inch SCH 80 conduits for solar and/or speaker driver wires.
PDF
PDF, High priority: read this firstspecifications
HighAI Summary for Exhibit H - General Electrical Specifications: Technical specifications for the installation of electrical system components and disaster warning systems. The document details requirements for conduits (PVC Schedule 80), copper conductors, grounding, and fiber-reinforced composite poles, including specific material standards (NEC, ASTM G154) and installation procedures for pole setting.
PDF
PDF, High priority: read this firstspecifications
HighAI Summary for Federal Signal Modulator MOD Series Speaker Specifications: Technical specifications, ordering guide, and installation manual for the Federal Signal Modulator High Powered Omni Speaker (MOD Series). The document includes detailed performance data (decibels, range, wattage) for various models (MOD1004B through MOD8032B), controller compatibility, and installation requirements.
DOCX
DOCX, High priority: read this firstsow
HighAI Summary for Q25001932 - Statewide Tsunami Siren Repairs SOW: Statement of Work for solicitation Q25001932 issued by the Hawaii Emergency Management Agency (HIEMA). The project involves the modernization and repair of seven tsunami sirens across Honolulu, Kaua'i, and Hawai'i counties, divided into three groups. Key requirements include solar panel replacement, electrical testing, and the provision of a journeyman electrician. The document specifies a pre-proposal conference on April 2, 2025, and requires contractors to hold a C13 State of Hawaii license.
PDF
PDF, High priority: read this first2 pages · rfq
HighAI Summary for Red Siren Repair Contractor Requirements: Dated November 22, 2024, this document outlines the contractor requirements for the Red Siren Repair project for the Hawaii Emergency Management Agency (HI-EMA). It specifies compliance with State of Hawaii laws, insurance and licensing requirements (C13 classification), a 90-day completion timeline from Notice to Proceed (NTP), and technical adherence to the National Electrical Code. It also details the coordination process with the HI-EMA Radioshop and the final inspection and acceptance criteria.
PDF
PDF, High priority: read this first1 page · specifications
HighAI Summary for Siren Repair Guidelines (11.25.24): Technical guidelines dated November 25, 2024, detailing repair and installation specifications for sirens. Key requirements include solar panel orientation, the use of stainless steel hardware, sealing protocols for conduits, approved battery models (Delco and Inter State), and a maximum ground resistance of 25 OHMS.
PDF
PDF, High priority: read this firstspecifications
HighAI Summary for UltraVoice UV Electronic Siren Controller Manual: Technical manual for the UltraVoice UV Electronic Siren Controller, including detailed specifications, installation instructions, operation guides, and service procedures. The document covers electrical connections, programming, battery maintenance, and wiring diagrams for speaker arrays and radio receivers.
HIEMA seeks a qualified vendor to modernize four (4) sirens located in Honolulu County. Locations are detailed in the aerial and street view pictures in the Statement of Work. Also, two (2) sirens in Kaua’i county, and one (1) siren on Hawai’i county.
Find Active Opportunities Like This
Get AI-powered intelligence on the opportunities still open
Every page of the solicitation package shredded into a compliance breakdown
AI-powered matching based on your capabilities and past performance
Competitor and incumbent history on the requirement
Automated alerts on amendments, Q&A deadlines, and award