Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, June 24 at 2:00 PM EDT

Register Free →

This Sources Sought opportunity from Department Of Defense was posted on December 9, 2021. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

STERILE STORAGE CABINET

Closed
N0020322STRLCABINETFederal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

General Info

Agency

Department Of Defense → Naval Hospital Pensacola Fl - MmView Agency

NAICS

339113 - Surgical Appliance and Supplies Manufacturing View NAICS

Place of Performance

Pensacola, FL, 32512, USA

Set-Aside

SBA

Documents

(0)

No documents available

AI Contract Breakdown

Uniform Contract Format

No contract breakdown available.

Cannot generate Contract Breakdown because no documents were found from this contract's source.

Timeline

1 update
PhaseClosed
Posted

Sources Sought

Amendment 1

Contract was updated

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → Naval Hospital Pensacola Fl - Mm
Contacts2 people available
OfficePENSACOLA, FL, 32512-0003, USA
Organization / Agency
Department Of Defense → Naval Hospital Pensacola Fl - Mm
View Agency Profile
Office AddressPENSACOLA, FL, 32512-0003, USA

Full Description

Show more
Requesting 6 cabinets with Exterior dimensions should be 30.5" W x 32" D x 77.5" H, Shelf quantity and dimensions: 5 - 27.75" W x 18" D, Overall Payload dimensions: 28" W x 19" D x 42" H, and estimated weight: 450lbs. Requesting installation and training for all 6 cabinets. Cabinets should have the following characteristics: - Exceeds requirements of VA Directive 1116(2); CSA (Canadian Standards Association) Z314.15-10; ANSI/AAMI ST79-2006; ANSI/ASHRAE/ASHE Standard 170-2017. Conforms with UL60601-1 - Have an onboard custom control system that provides easy operation utilizing a digital display for monitoring temperature, humidity, pressure and status. - Maintains a temperature of 66F to 72F - Contain integral pressure monitoring with alarm - Maintains Humidity at 20% to 60% RH - Must have steam humidification utilizing standard demineralized water - Maintains positive pressure +0.03"WC - Should have an integral 3/4 gallon reservoir filled through front spout access - Meets IEC 60601-1 Medical Standard for Power Supplies - Requires a 120V hospital grade 10ft long plug-in-cord - 55-59 DBA at 3 feet (1 meter) - Requires a HEPA Filtration designed to exceed ISO 6 Cleanliness or better in some environments - Optional ducted heat exhaust - Requires to have 230 air changes per hour - Requires UV-C light (bathes HEPA filter) - Equipped with a Integrated condensate control system - Capability to interface with VAnetwork environmental monitoring system via an access port.