This Solicitation opportunity from Government of Canada was posted on August 12, 2021. The submission period has ended. Browse the details below for market research, or find similar active opportunities.
STORAGE SHED AT OIL CITY DEPOT
Awarded
BT-2021-149CanadaSubmission Closed
Contract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
General Info
Place of Performance
ON, CANSet-Aside
NONE
Awardee
National Building GroupView Profile
Award Issued Date
Documents
(3)AI Contract Breakdown
Uniform Contract FormatWhat is UCF?
Uniform Contract Format (UCF) uses AI to break down any contract into standardized sections—scope, pricing, deliverables, and evaluation criteria.
Timeline
PhaseAwarded
Submission Closed
Organization & Contact Information
Show more
AgencyGovernment of Canada → County of Lambton
ContactsNo contacts available
OfficeN/A
Office AddressN/A
ContactsNo contact information available
Interested Companies (2)
Show more
National Building Group
Wellandport, ON
Britespan Building Systems Of Ontario
Wingham, Ontario
Full Description
Show more
The scope of work within this requirement is to provide a design/build option to complete a Pre- Engineered Fire Rated Fabric Storage Building at the County of Lambton Public Works Oil City Depot, 3020 Oil Heritage Road, Oil City, Ontario. The Storage building shall be 32' wide x 28' long with an internal clearance of 18' over a width of 16' as shown on the preliminary drawings attached. These drawings are to be used for clarity purposes only and the County of Lambton expects a complete set of Engineer stamped drawings from the Contractor.The Contractor shall be responsible to supply all necessary Engineer stamped drawings, building permits, site preparation, granular, compaction and setting of the concrete blocks as per the Pre- Engineered design and also all labour, materials and equipment to complete the construction of the building. The County of Lambton has 2'x2'x4' long pre- cast concrete blocks available for use if they meet the criteria of the foundation design.The Storage building shall have one end fully opened and one end Enclosed and shall include the structural framework and FR Fabric cladding with one 24" x 24" Gable End Louver vent as per the design.The Fire Rated Fabric storage building must also have a 15 year pro- rated warranty on the fabric and on the steel against any flaking of the coating or defects in the performance of the material or workmanship.
