Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, September 30 at 2:00 PM EDT

Register Free →

Strain Insulator

Active
Z5250State & Local

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

Nashville Electric Service has issued solicitation Z5250 for the procurement of 1,010 fiberglass strain insulators. Each unit must be 54 inches in length, feature a clevis with a roller on one end and a thimble/eye on the other, and possess a minimum breaking strength of 21,000 lbs. Only specific approved manufacturers and part numbers are acceptable, including Hubbell GS21054CP1, Gamma GS2154-TR, Preformed GSF21-54CTR, Maclean GCTE21-54R, and Aluma-Fo FGS21-54RT. Alternate brands will not be accepted for this inquiry. Bids must be submitted through the Bid Center by 2:00 pm local time on October 2, 2026. Vendors are required to state their earliest delivery time in calendar days, as delivery speed may be a determining factor in the award decision. The primary procurement contact for this solicitation is Tiffany Caruthers.

General Info

Nashville Electric Service seeks 1,010 specific fiberglass strain insulators by October 2, 2026.

Documents

(1)

RFB Z5250 - Strain Insulators

PDF•rfb

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

PhaseSolicitation
Posted

Solicitation

Response Deadline

Submission deadline

Response Deadline

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyTennessee → Nashville Electric Service
Contacts1 person available
OfficeNashville, TN, USA
Office AddressNashville, TN, USA
Contacts
Tiffany CaruthersProcurement Contact

Full Description

Show more
EA INSULGUY STRN/FIB GLASS54 IN STRAIN INSULATOR,54" OF FIBERGLASS, CLE VIS WITH ROLLER ON ONE END, THIMBLE/EYE ON OTHEREND. 21,000 LB. MINIMUM BREAKING STRENGTH. HUBBEL GS21054CP1 GAMMAGS2154-TR PREFORME GSF21-54CTR MACLEAN GCTE21-54R ALUMA-FO FGS21-54RT Stateyour earliest delivery IN CALENDAR DAYS: _ DELIVERY MAY BE CONSIDEREDIN THE AWARDOF THIS BID. _ Alternate brands will not be accepted on this inquiry. To have your product evaluated for future consideration, contact the buyerlisted in this RFB. _ In the eventof a discrepancy between the ordering description and part number, it is the responsibility of the vendor to contact the buyerfor clarification before the published CLOSE DATE. _ Note: This bid must be submitted usingthe Bid Center and must be received by 2:00 pm localtime on the published CLOSE DATE. _

Similar Contracts

Same NAICS industry code

NAICS: 423610
New
Federal
LMR Tower Bulb Replacement
Solicitation # FA452826QTC01
Solicitation FA452826QTC01 is a Firm-Fixed Price requirement for the procurement and replacement of Land Mobile Radio LMR tower bulbs at Minot Air Force Base, North Dakota. The scope of work includes the maintenance and replacement of beacon, obstruction, and aircraft warning lights across designated Missile Alert Facilities and one south base site. Specifically, the contractor is required to replace 33 bulbs and clean associated globes, replace 6 warning light fixtures, and perform necessary repairs on non-functional equipment. All installation work must be performed by an electrician licensed in the state of North Dakota, and all materials must meet NEMA requirements and adhere to NFPA 70 and ICC electrical codes. This requirement is a 100 percent total Small Business set-aside under NAICS code 423610. Award will be based on the Best Value to the Government, evaluating technical capability on a pass/fail basis, price, and past performance, with past performance weighted approximately equal to price. The response deadline was extended to September 28, 2026. The contractor is required to maintain a quality control program, submit manufacturer certificates of compliance for all materials, and utilize the Wide Area WorkFlow system for electronic invoicing. Security requirements include compliance with DD Form 254 and specific vehicle registration and insurance documentation for installation access.
FA4528 5 Cons

POSTED

about 6 hours ago

DEADLINE

in 3 days
View Details

More opportunities from Tennessee → Nashville Electric Service

Same awarding agency

Ready to Pursue This Opportunity?

Get AI-powered intelligence on this solicitation and the ones like it

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS