Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Government Contract opportunity from North Carolina was posted on April 29, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Structural Engineering for Roof Load Analysis

Closed
State & Local

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 541330
New
SLED
RFP/RFQ - On-Call Engineering Services for Torrington Transfer Station/NRRA
Solicitation # EDC 11- 2026 -01
The Northwest Hills Council of Governments (NHCOG) is soliciting proposals under solicitation number EDC 11- 2026 -01 for on-call engineering services to support the Torrington Transfer Station and the Northwest Resource Recovery Authority (NRRA). The agency seeks a qualified firm specializing in Municipal Solid Waste and Recycling Transfer Stations to provide technical analysis, facility and operational capacity assessments, site planning, and permitting assistance. These services are intended to support ongoing operations and inform the NRRA Strategic Plan and future capital investment decisions, ensuring compliance with CT DEEP General Permits. Interested firms must submit their proposals by November 30, 2026, at 11:00 AM. Submissions must include a project management plan, key personnel resumes limited to two pages, three relevant references, a technical approach, and a detailed project timeline. A fee proposal containing hourly rates or lump sum allocations must be submitted in a separate sealed envelope. Evaluation will be based on personnel qualifications, experience with multiuse trails and waste facility planning, the proposed project approach, and the fee schedule. Awardees must provide proof of workers compensation, liability, and vehicle insurance, including a waiver of subrogation and naming the State of Connecticut and NHCOG as additional insureds within ten days of the award. Required documentation also includes a Non-Collusion Affidavit and certifications of non-discrimination.
DAS Procurement

POSTED

about 10 hours ago

DEADLINE

in about 1 month

AI Contract Overview

Show more

The contract involves conducting a structural assessment of the Patterson Building, constructed in 1975, to determine its load-bearing capacity in support of a new roofing system. The scope includes detailed deflection analysis to evaluate how the existing structure will respond to the additional weight and stress of the proposed roofing materials, along with specific recommendations for reinforcement where necessary to ensure safety and compliance with structural standards. The assessment must account for the building’s age, original construction methods, and potential degradation over time to provide accurate and reliable findings. This subcontract, classified under NAICS code 541330 for architectural and engineering services, is issued by Stanly Community College in North Carolina with a response deadline of May 14, 2026. The work is to be performed at the building’s location, though the exact address is not provided, and the solicitation was posted on April 29, 2026. No set-aside provisions or specific organizational type requirements are indicated, and no point of contact information is listed, with all communication and submissions directed through the provided online portal.

General Info

Structural assessment of 1975 Patterson Building for new roofing load capacity and reinforcement recommendations.

Place of Performance

NC, USA

Set-Aside

NONE

Documents

This scope was carved out of NCCS #3015; SCO #31141.

The full solicitation package (1 document), including the RFP, is on the prime solicitation, not on this scope.

View the prime solicitation

Designer Services for Patterson Building Roof Replacement

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseClosed
Posted

subcontract

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyNorth Carolina → Stanly Community College
ContactsNo contacts available
OfficeN/A
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
Perform structural assessment of the 1975-built Patterson Building to evaluate load capacity for new roofing system, including deflection analysis and reinforcement recommendations.

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS