Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

SUCF# 161105 Replace Cooling Tower - Kenneth Post Laboratory

Active
2140165State & Local

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

Cornell University is seeking Statement of Qualifications from engineering consultants for solicitation 2140165 to provide design services for the Kenneth Post Laboratory. The project involves removing the existing cooling tower and chiller equipment and converting the building to the campus chilled water distribution system. The scope of work includes investigating existing conditions, designing the new campus chilled water connection, preparing construction documents and cost estimates, coordinating with stakeholders, and providing bidding and construction administrative services. The estimated completion date for the project is December 31, 2028, with a contract term of one to two years. Proposals must be submitted in PDF format, not exceeding 25 pages, and emailed to the Capital Planning Manager by the deadline specified in the New York State Contract Reporter ad. Evaluation will be based on the prime consultant's experience, staff qualifications, technical approach, and previous work with educational or state agencies. No fee information should be included in the initial submission, as fee proposals will only be requested after a consultant is selected. The contract mandates specific diversity goals, including a 9 percent MBE goal, an 11 percent WBE goal, and a 6 percent SDVOB goal, which must be detailed using the required Subconsultant Staffing List.

General Info

Cornell University seeks engineering consultants for Kenneth Post Laboratory chilled water system design.

Place of Performance

512 Tower Road, Ithaca, NY 14850, NY, USA

Set-Aside

NONE

Documents

2

Subconsultant Staffing List – Architecture and Engineering

DOCX, High priority: read this first4 pages · specifications
High

SUCF# 161105 Replace Cooling Tower - Kenneth Post Laboratory

PDF, High priority: read this firstrfq
High

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

PhaseSolicitation
Posted

Solicitation

Response Deadline

Submission deadline

Response Deadline

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyNew York → Cornell University
Contacts2 people available
OfficeN/A
Organization / AgencyNew York → Cornell University
Office AddressN/A
Contacts
Danielle CoxCCF Capital Planning Manager
Danielle CoxCCF Capital Planning Manager

Full Description

Show more
SUCF# 161105 Replace Cooling Tower - Kenneth Post Laboratory Request for Qualifications Cornell University is seeking SOQs from consultants to provide engineering design services to support the removal of the existing cooling tower and chiller at Kenneth Post Laboratory. Project Description This project will remove the existing cooling tower and chiller equipment serving Kenneth Post Laboratory and convert the building’s cooling system to utilize Cornell University’s campus chilled water distribution system. The project will include evaluation and design of a new campus chilled water connection, removal of obsolete cooling equipment, modifications to existing mechanical, electrical, and controls systems, and associated infrastructure improvements necessary to support continued building operations. The conversion is intended to improve system reliability, reduce maintenance requirements, eliminate aging equipment, and take advantage of the efficiency and reliability of Cornell’s campus chilled water network. Scope of Services The services indicated below shall include, but not be limited to: · Investigate existing conditions and project requirements · Design the conversion from local cooling equipment to campus chilled water system · Prepare construction documents, technical specifications, and cost estimates · Coordinate with University stakeholders and utility representatives · Bidding phase (one contractor to execute all work – sub-phased) · Construction administrative services Project Reference Materials (if applicable): None Minority- and Women-Owned Business Enterprise (MWBE) Participation Pursuant to New York State Executive Law Article 15-A, Cornell University is committed to promoting opportunities for maximum feasible participation of certified MWBE firms and the employment of minority group members and women in the performance of Cornell contracts. Consultants are required to ensure that good faith efforts are made to include meaningful participation. Service-Disabled Veteran-Owned Business Enterprise (SDVOB) Participation Pursuant to New York State Executive Law Article 17-B, Cornell University is committed to promoting opportunities for maximum feasible participation of certified SDVOB firms and the employment of veterans in the performance of Cornell contracts. Consultants are required to ensure that good faith efforts are made to include meaningful participation MBE, WBE, and SDVOB goals are listed in the New York State Contract Reporter (NYSCR) ad. The consultant shall provide a Subconsultant Staffing List for the project using the form attached to the NYSCR ad. This subconsultant staffing list shall include the percent of work to be completed by each subconsultant and indicate whether each subconsultant is a MBE, WBE, or SDVOB. References References will be contacted as part of the evaluation process. When submitting references, the following information shall be included: · Name(s) and title(s) of person/people to contact · Phone numbers and e-mail addresses · Name of project and/or reason for reference Time of Completion Schedule Estimated Completion Date: December 31, 2028 Format of Proposal To be considered for this project, prospective consultants shall include the following in their response: 1) Cover letter with signature. 2) Prime Consultant’s Qualifications and Experience: Show specific relevant expertise and successful completion of projects similar in size and scope as the project described above. 3) Qualifications of Prime Consultant Staff: Demonstrate experience and qualifications of the firm’s key personnel in the planning, organizing and execution of projects similar in scope. List the qualifications of employees who will be working on this project. 4) Approach and Capability: Show organization of staff and design/technical resources specifically dedicated to this project. Identify assignment of responsibilities and authority. 5) Previous Experience with Work Specific to Project Scope: Include examples of prior work on Cornell projects and other colleges and/or state agencies. Demonstrate thorough understanding of project scope. 6) Proposed Subconsultant Team: List subconsultants who will work on this project and demonstrate that they have the necessary staffing and experience for this type of work. 7) MWBE and SDVOB Utilization: On the Subconsultant Staffing List, list all MBE, WBE, and SDVOB staff and subconsultants who will work on this project to show how the MWBE/SDVOB goals will be met. If the prime consultant is an MWBE/SDVOB firm, it counts towards the goals. 8) References: List references for design and construction administration of similar projects in public and educational settings. Deadline and Submittal Information 1) Proposals must be received on or by the due date listed in the NYSCR ad. 2) Proposals must be in PDF format, no more than 25 pages total (including cover sheet and all forms), and labeled using the following naming convention: SUCF#-Project Name-Firm Name 3) Proposals shall be e-mailed to: ccf-admin@cornell.edu 4) If inquiries regarding the project are received, all answers given will be posted at the following link: https://fcs.cornell.edu/current-nys-contract-reporter-ad-inquiries No fee information is to be submitted with the proposal. A fee proposal will be requested only after a consultant selection is made. Business enterprises awarded an identical or substantially similar procurement contract within the past five years: None Service-Disabled Veteran-Owned Business (SDVOB) SDVOB Goal: 6.00% Minority / Women Business Enterprise contracting goals (MWBE) MBE Goal: 9.00% WBE Goal: 11.00%

Similar Contracts

Same NAICS industry code

NAICS: 541330
New
SLED
(RFQ) 27-23, Engineering and Design Services for Gardner Road Bridge
Solicitation # 27-23
The Henry County Board of Commissioners is soliciting proposals for professional engineering services for the Gardner Road Bridge Improvement Project. The scope of work involves evaluating existing hydraulic, structural, and roadway conditions at the Gardner Road stream crossing to develop recommendations for replacing a culvert crossing with a bridge structure. Key objectives include increasing hydraulic capacity, reducing flooding potential, and enhancing public safety and roadway resiliency. The selected contractor will be responsible for all labor, materials, and equipment necessary to complete project management, surveying, field investigations, hydrologic and hydraulic analysis, structural evaluation, environmental permitting, geotechnical services, and the preparation of 30 percent preliminary and 90 to 100 percent final construction documents. Qualified vendors must submit their responses by 3:00 PM local time on November 19, 2026, via the County's eProcurement Portal or in person at the Henry County Purchasing Department. Submissions must include a sealed envelope containing one unbound original, one bound copy in a half-inch ring binder, and a PDF version on a labeled USB flash drive. Required documentation includes a detailed fee proposal, a W9 form, and several certifications, including a Drug Free Workplace Certification, a Covenant of Non-Discrimination, and a Georgia Security and Immigration Compliance Act affidavit. Award selection is based on the most qualified firm, with potential for additional points via oral presentations. The contract requires comprehensive insurance coverage, including $1,000,000 for professional liability, automobile liability, and each occurrence of general liability, with a $2,000,000 umbrella policy. All work must comply with OSHA and applicable local, state, and national codes. Henry County maintains the right to terminate the contract for convenience with 30 days' written notice or for default after a 30-day notice period. Payment is contingent upon the County's acceptance of completed services and the submission of original invoices containing the specific purchase order and bid package numbers.
Henry County Board of Commissioners

POSTED

about 9 hours ago

DEADLINE

in 28 days
View Details

More opportunities from New York → Cornell University

Same awarding agency

Ready to Pursue This Opportunity?

Get AI-powered intelligence on this solicitation and the ones like it

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS