Terminal Avenue Pumping Station Surge Tower Bypass
Open
terminal-avenue-pumping-station-surge-tower-bypassResponse Deadline
Contract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
General Info
Agency
Place of Performance
Set-Aside
SBA
Documents
0No documents available
Documents will appear here when they are available.
AI Contract Breakdown
Uniform Contract FormatNo documents to break down
The breakdown needs solicitation documents. None were found from this contract's source.
Get what you need to respond
No documents were posted with this contract.
- Buyer contactEmail and phone
- Original solicitationLink to the source posting
Ask CLEATUS
I've read this contract. Ask me anything.
Timeline
PhaseSolicitation
Posted
Solicitation
Response Deadline
Submission deadline
Response Deadline
Organization & Contact Information
Show more
AgencyGarney Companies, Inc.
Contacts1 person available
OfficeN/A
Organization / AgencyGarney Companies, Inc.
Office AddressN/A
Full Description
Show more
Construct a new sanitary sewer force main bypass system at the Terminal Avenue Pumping Station in New Castle, Delaware. The work includes site demolition, installation of new 36-inch, 24-inch, 20-inch, and 14-inch ductile iron force mains and associated fittings, construction of valve vaults and surge relief structures, installation of valves and appurtenances, dewatering operations, removal of portions of the existing force main, testing and startup of the new system, pavement and fence restoration, erosion and sediment control measures, landscaping, and all related site restoration work required to place the bypass system into service. Phase 1 is to locate the existing force main, install Bypass force main, surge relief valve piping, surge relief valve vault, 24" insolation Valve Vault, and backfill. Phase 2 is to establish force main dewatering connection, coordination closure of 36" knife gate valve to isolate the 36" force main, dewater existing Terminal Ave. force main via a 6" tap, then open cut pipe to pump out remaining water. Phase 3 is to remove a portion of the 36" PCCP force main, install remaining force main isolation valve, vault and piping. Close 24" isolation valve, connect to potable water and flush and drain at flushing connection at tapping saddles to flush line and drain at flushing connection in 24" isolation vale vault. Pressure tests the 36" force main and gain acceptance from owner. Phases 2 and 3 will require 24-hour operation and have to be completed in a 72-hour timeframe.
Similar Contracts
Same NAICS industry code
Get AI-powered intelligence on this solicitation and the ones like it
Every solicitation package arrives shredded into a compliance breakdown and matched to your past performance, with incumbent history and alerts on amendments and award.
Join 900+ contractors already using CLEATUS
