TEST SET, WATER TURB

Closed
SPE2DH-26-T-5421Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

AI Contract Overview

Show more

The contract specifies the procurement of two each of a water turbidity meter test set compliant with ISO 7027, featuring a four-key interface and weighing 350 grams. The device measures turbidity from 0 to 1000 FTU (NTU) using an infrared LED light source and incorporates Good Laboratory Practice circuitry that automatically stores and retrieves the last calibration data, displaying the time and date of calibration with a single key press to support accurate calibration scheduling. It includes an auto shut-off function that powers down the unit after five minutes of inactivity to conserve battery life. The kit is supplied with a measurement cuvet and cap, four 1.5V AA batteries, and an instruction manual. The item is identified by NSN 6630-01-490-7581 and must be delivered within 20 days to Fort Bliss, Texas. The item is classified as a TYPE I (CODE F) shelf-life item with a strict six-month non-extendable shelf life, requiring that no more than three weeks have elapsed from the manufacturer's date to the date of government receipt. Packaging and labeling must comply with Medical Marking Standard No. 1, superseding MIL-STD-129, and include the date of manufacture, expiration or retest date, contract number, and lot number. Packaging must be commercial-grade, sealed, and suitable for safe transport by common carriers at the lowest possible rate. The acquisition falls under DLA Master List technical and quality requirements, incorporates DLA packaging standards, and applies to all medical acquisitions, with additional compliance for covered defense information and removal of government identification from non-accepted supplies. The solicitation number is SPE2DH-26-T-5421, issued by the Department of Defense's Medical Supply Chain FSH, with a response deadline of July 29, 2026, and primary point of contact Tina Vu.

General Info

Procure two ISO 7027-compliant turbidity meters with calibration storage, six-month shelf life, delivery to Fort Bliss by 20 days.

Agency

Department Of Defense → MEDICAL SUPPLY CHAIIN FSHView Agency

NAICS

423450 - Medical, Dental, and Hospital Equipment and Supplies Merchant WholesalersView NAICS

Place of Performance

21287 LIGHT INFANTRY AVENUE, FORT BLISS, TX, 79918-2527, USA

Set-Aside

NONE

Documents

(1)

RFQ SPE2DH-26-T-5421 Medical Supply Chain

PDFrfq

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

PhaseClosed
Posted

Solicitation

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → MEDICAL SUPPLY CHAIIN FSH
Contacts1 person available
OfficeUSA
Organization / Agency
Department Of Defense → MEDICAL SUPPLY CHAIIN FSH
View Agency Profile
Office AddressUSA

Full Description

Show more
TEST SET,WATER TURB
TEST SET, WATER TURBIBITY METER
COMPLIES WITH ISO 7027; FEATURES WITH 4 KEYS AND WEIGHS 350 GRAMS;
MEASURES TURBIDITY FROM 0 TO 1000 FTU (NTU);EQUIPPED WITH INFARED LED AS
SOURCE OF LIGHT; GOOD LABORATORY PRACTICE FEATURE CIRCUITRY
AUTOMATICALLY STORES AND RETRIEVES THE LAST CALIBRATION DATA; AT TOUCH
OF A KEY, LAST CALIBRATION DATA WITH TIME AND DATE ARE DISPLAYED
ALLOWING USER TO MAINTAIN AN ACCURATE CALIBRATION SCHEDULE; AUTO SHUT
OFF TURNS METER OFF AFTER 5 MINUTES OF NON USE TO SAVE BATTERIES;
SUPPLIED WITH MEASUREMENT CUVET AND CAP, FOUR 1.5 V AA BATTERIES AND
INSTRUCTION MANUAL
UNIT OF ISSUE: EA (EACH)
..
RA001: THIS DOCUMENT INCORPORATES TECHNICAL AND/OR QUALITY REQUIREMENTS
(IDENTIFIED BY AN 'R' OR AN 'I' NUMBER) SET FORTH IN FULL TEXT IN THE
DLA MASTER LIST OF TECHNICAL AND QUALITY REQUIREMENTS FOUND ON THE WEB
AT:
http://www.dla.mil/HQ/Acquisition/Offers/eProcurement.aspx http://www.dla.mil/HQ/Acquisition/Offers/eProcurement.aspx
FOR SIMPLIFIED ACQUISITIONS, THE REVISION OF THE MASTER IN EFFECT ON THE SOLICITATION ISSUE DATE OR THE AWARD DATE CONTROLS. FOR LARGE ACQUISITIONS, THE REVISION OF THE MASTER IN EFFECT ON THE RFP ISSUE DATE APPLIES UNLESS A SOLICITATION AMENDMENT INCORPORATES A FOLLOW-ON REVISION, IN WHICH CASE THE AMENDMENT DATE CONTROLS.
..
RD003, COVERED DEFENSE INFORMATION POTENTIALLY APPLIES
..
RP001: DLA PACKAGING REQUIREMENTS FOR PROCUREMENT
..
RQ011: REMOVAL OF GOVERNMENT IDENTIFICATION FROM NON-ACCEPTED SUPPLIES
..
APPLICABLE TO ALL MEDICAL ACQUISITIONS:
PACKAGING AND PACKING SHALL BE COMMERCIAL AS
SPECIFIED IN THE PROCUREMENT DOCUMENT.
EACH COMPLETE UNIT SHALL BE PROPERLY PACKAGED
IN A SUITABLE SEALED UNIT CONTAINER CAPABLE
OF PROTECTING THE CONTENTS FROM DAMAGE AND/OR
BREAKAGE.
UNITS SHALL BE PACKED IN SUITABLE COMMERCIAL
EXTERIOR (SHIPPING) CONTAINERS (EXPORT WHEN
NECESSARY) WHICH SHALL INSURE ACCEPTANCE AND
SAFE DELIVERY BY COMMON OR OTHER CARRIER, AT
THE LOWEST RATE, TO POINT OF DELIVERY CALLED
FOR IN THE CONTRACT OR ORDER.
MATERIAL MUST BE MARKED IAW MEDICAL MARKING
STANDARD NO. 1. THIS SUPERCEDES ALL REFERENCES
TO MIL-STD-129.
COPIES OF MEDICAL MARKING STANDARD NO. 1
(MMS NO. 1) MAY BE OBTAINED BY CONTACTING DLA
SPE2DH-26-T-5421
SECTION B
TROOP SUPPORT VIA EMAIL TO fssb@dla.mil. MMS NO. 1 IS ALSO AVAILABLE ONLINE AT: https://www.dla.mil/Logistics-Operations/Packaging/
.. RS008: Shelf-life requirement RS001 for a TYPE I (CODE F) item with a shelf life of 6 months (non-extendable) applies to this item.
SHALL HAVE A SHELF LIFE OF 6 MONTHS. NOT MORE THAN 3 WEEKS SHALL HAVE ELAPSED FROM DATE OF MANUFACTURE TO DATE OF DELIVERY TO THE GOVERNMENT. . SHELF LIFE MARKINGS SHALL BE IN ACCORDANCE WITH THE LATEST REVISION OF MMS1C.
. ALL LABELS SHALL INCLUDE:
DATE OF MANUFACTURE, EXPIRATION, OR RETEST DATE CONTRACT NUMBER/LOT NUMBER. .. ADEQUATE DATA FOR THE NSN/Part Number: 6630-01-490-7581 Quantity: 2 EA Purchase Request: 7017578714QTY: 2 Delivery: 20 days ADO

More opportunities from Department Of Defense → MEDICAL SUPPLY CHAIIN FSH

Same awarding agency

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 650+ contractors already using CLEATUS