The work consists of providing all supervision, labor, materials, and equipment as required to: Repair approximately 600 square feet of damaged hangar floor coating with urethane topcoated epoxy floor with moisture mitigation.

Awarded
HSCG4217F5PT103Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

AI Contract Overview

Show more

This contract requires the repair of approximately 600 square feet of damaged hangar floor coating at the USCG National Capitol Region Air Defense Facility located at Washington Reagan National Airport. The scope of work involves a three-coat system consisting of a moisture mitigating primer, a high performance epoxy intermediate coat, and a pigmented aliphatic polyester urethane finish coat designed to resist aviation fluids and tire marking. The government will furnish the primer, intermediate coat, and finish coat, while the contractor is responsible for all supervision, labor, equipment, and the addition of a sand broadcast for traction. Work must commence within 20 days of the notice to proceed and be completed within 35 working days of the contract award. The contractor is responsible for rigorous surface preparation, moisture testing via the Calcium chloride method, and strict adherence to OSHA and EPA safety and environmental regulations. Additionally, the contractor must coordinate all activities with the Metropolitan Washington Airport Authority, provide detailed personnel lists for security clearance five days prior to start, and ensure all hazardous materials are disposed of according to federal, state, and local guidelines.

General Info

Contractor will repair 600 square feet of hangar floor coating within 35 days.

Contract Value

$9,492

NAICS

238390 - Other Building Finishing Contractors

Place of Performance

USCG National Capitol Region Air Defense Facility (NCRADF), Washington Reagan National Airport, Hangar 5 Washington, D.C. 20010, ARLINGTON, VA, 22202, USA

Set-Aside

NONE

Award Issued Date

Documents

19

IMG_2240.jpg

JPG

IMG_2241.jpg

JPG

IMG_2242.jpg

JPG

IMG_2243.jpg

JPG

IMG_2244.jpg

JPG

IMG_2245.jpg

JPG

IMG_2246.jpg

JPG

IMG_2247.jpg

JPG

IMG_2248.jpg

JPG

IMG_2249.jpg

JPG

IMG_2250.jpg

JPG

IMG_2251.jpg

JPG

IMG_2252.jpg

JPG

IMG_2253.jpg

JPG

Ref_Info.doc

DOC

RFI.doc

DOC

RFQ_solic_including_embedded_docs_-_NCRADF_Floor.doc

DOC

SOW_NCRADF_Floor_Patchwork.doc

DOC

wage_rates.pdf

PDF

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

2 updates
PhaseAwarded
Posted

Presolicitation

Notice updated

NAICS code changed from 238190 to 238390. The notice description changed.

Notice updated

The notice description changed.

Type Changed

Presolicitation → Solicitation

Awarded

Contract was awarded

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Homeland Security → Tracen Cape MAY(00042)
Contacts1 person available
OfficeCAPE MAY, NJ, 08204, USA
Office AddressCAPE MAY, NJ, 08204, USA
Contacts

Full Description

Show more
1. GENERAL REQUIREMENTS: The work consists of providing all supervision, labor, materials, and equipment as required to: Repair approximately 600 square feet of damaged hangar floor coating with urethane topcoated epoxy floor with moisture mitigation. All work is located at USCG National Capitol Region Air Defense Facility (NCRADF), Washington Reagan National Airport, Hangar 5 Washington, D.C. 20010. 2. COMMENCEMENT, PROSECUTION, AND COMPLETION OF WORK: Upon acceptance, the Contractor shall commence work NLT twenty (20) days after notice to proceed, and work diligently to complete the entire project to be ready for use NLT thirty five (35) working days after contract award. 3. SCOPE OF WORK: (1) Floor Repairs a. System requirements: 100% Solids Self-leveling Epoxy with a Urethane Finish Coat. 1. The first coat will consist of a 100% solids epoxy moisture mitigating primer followed by and intermediate coat of high performance epoxy with a topcoat of pigmented aliphatic polyester urethane that will provide a high level of resistance to wear and chemical compounds. The urethane used must provide a high level of resistance to wear and chemical compounds. The urethane used must provide complete resistance to standard industrial and aviation fluids as well as tire marking and hot tire pickup. b. Surface Preparation: 1. All concrete surfaces must be sound, clean, dry, cured and profiled. Concrete surfaces shall have tensile strength of not less than 250-300 psi, and have a pH range of 7-9. All concrete surfaces shall be free of surface hardeners, form release agents, curing compounds, laitance, efflorescence, chloride contamination, and hydrostatic water pressure or excessive capillary water action, and/or water vapor emissions. All concrete surfaces shall be cleaned first with a strong detergent to remove oils, grease, and dirt before proceeding with acid etching, sandblasting, shot blasting, or mechanical scarification. 2. Reference International Concrete Repair Institute, Guideline No. 03732 - Selecting and specifying concrete surface preparation for sealers, coating and polymer overlays (including visual standards), Jan. 1991. Phone +1 (555) 000-0000, Fax +1 (555) 000-0000; and SSPC/NACE Publication No. 01-10 - Fundamentals of Cleaning and Coating Concrete, 2001, Phone +1 (555) 000-0000. c. Coating System: 1. *Primer - TuffRez MMP at 140 to 160 sq.ft. per gallon for 10-12 mils DFT. 2. *Intermediate coat - Wearcoat 480 at 140 to 160 sq.ft per gallon for 10-12 mils DFT 3. *Finish coat - Wearcoat 100 at 220 to 250 sq.ft. per gallon for 4-6 mils DFT. 4. Add 30% broadcast using 4/0 sand to provide traction on surface. *Items 1 thru 3 are government furnished materials. d. Moisture testing: 1. An approved moisture test must be performed prior to coating. The preferred method for testing is the Calcium chloride Test (ASTM F - 1869-98). 4. SITE VISIT: All bidders are strongly encouraged to visit the site to verify any/all quantities before submitting bids. Interested parties shall make arrangements for a site visit with LT Katherine Voth @ +1 (555) 000-0000 or DCC Nicholas Mimms @ +1 (555) 000-0000. 5. DESIGNATED CONTRACTING OFFICER'S QA EVALUATOR (QAE) REPRESENTATIVE: The designated contracting officer's QAE representative and Point of Contact for this project is DCC Nicholas Mimms @ +1 (555) 000-0000 or Jim Smith @ +1 (555) 000-0000. 6. CONDITIONS AFFECTING THE WORK: The contractor should visit the site and take such other steps as may be reasonably necessary to ascertain the nature and location of the work, the general and local conditions which can affect the cost of the work thereof. Failure to do so will not relieve bidders from responsibility for estimating properly the difficulty or cost of successfully performing the work. The government will assume no responsibility for any understanding or misrepresentations concerning conditions made by any of its officers or agents prior to the execution of the contract, unless included in the request for quotes, the specification or related documents. All work shall be coordinated and approved through Metropolitan Washington Airport Authority airport manager POC: Jeremy Meltzer @ +1 (555) 000-0000, contact@example.gov as per Coast Guard lease agreement MWAA-LN-04-04. 7. AFTER AWARD OF THE CONTRACT: The contractor must immediately notify the contracting officer's QAE representative of the intended start date. The work shall be done in accordance with the specification. 8. ORAL MODIFICATION: No oral statements of any person other than the contracting officer shall in any manner or degree, modify or otherwise affect the terms of this contract. 9. WORKMANSHIP: All work shall be accomplished with the best standard practices, and by workmen thoroughly experienced in the required trades. The work shall be supervised by experienced personnel and shall be satisfactory to the Contracting Officer. 10. PERMITS: The contractor shall without additional expense to the government, obtain all appointments, licenses, and permits required for the prosecution of the work. The contractor shall comply with all applicable federal, state and local laws. 11. CLEAN UP: All trash and debris shall be removed from the site daily. The job site shall be left in a clean and neat manner. 12. WORK OUTSIDE REGULAR HOURS: If the contractor desires to carry on work on Saturday, Sunday, holidays or outside the unit's regular hours (0730-1600), they must submit their request in writing to the Contracting Officer's QAE Representative for approval consideration. The contractor shall allow ample time to enable satisfactory arrangements to be made by the Government for inspecting the work in progress. 13. UPON COMPLETION OF WORK: Contact the Contracting Officer's QAE Representative to arrange for inspection/acceptance of work. 14. IDENTIFICATION OF CONTRACTOR PERSONNEL AND VEHICLES: The contractor shall provide a detailed list of all employees to the QAE Representative five (5) days prior to commencing work. The employee list shall contain the employee's full name, date and place of birth, current address and last four (4) of SSN. The NCRADF's Security Officer MEC Shane Coleman +1 (555) 000-0000 will be given a copy of the employee list and a pass will be issued for entry. Each contractor provided vehicle or towed trailer shall show the contractor's name so that it is clearly visible on the vehicle. A valid state license plate and safety inspection sticker is required. All vehicles operated on government property shall be maintained in a good state of repair. 15. SAFETY REQUIREMENTS: 1. Responsibilities: a. All contractors working on NCRADF shall abide by all federal safety regulations as published by the Occupational Health and Safety Administration, 29 CFR 1910 (series), 29 CFR 1925 (series) and 29 CFR 1926 (series). Contractor written safety programs shall be reviewed by the Safety Officer prior to starting work. b. Written notification must be provided to the NCRADF Safety Officer, LT Katherine Voth @ +1 (555) 000-0000 in their capacity as Fire Marshal of any activity that could potentially cause fire or explosion or those changes or reduces the capability of fighting a fire or explosion. Some examples of qualifying activities are: a fire hydrant or fire suppression system that must be taken out of service for any reason, electrical work that affects fire alarm systems, introduction of hazardous or flammable material onto the unit, and blocking of any egress routes or emergency vehicle routes. Inclusion of this information in the contract constitutes written notification as long as the outsource review sheet is signed by Safety Officer. c. Copies of the following must be provided to the Safety Officer, prior to starting work in affected areas: Confined Space Entry Permits, Hot Work Chits, and Dig Chits. Confined space clearance must be conducted by a certified marine chemist and permit required spaces will have a copy of the permit posted on site during work. Hot work will only be conducted with permission and a fire watch must be posted during work. d. Lock Out/Tag Out requires notification and coordination with facilities and will not be conducted by a contractor on NCRADF. A Facilities Division representative is required for all contractor Lock Out/Tag Out needs. 2. Rights: a. Every employee working on NCRADF has the right to a safe and healthy work place. The contractor has the responsibility and right to stop unsafe work. QAE's and the Safety Officer may also institute a work stoppage relating to unsafe practices or immediate danger to life and health situations. 16. ENVIRONMENTAL PROTECTION REQUIREMENTS: a. All contractors working on NCRADF shall abide by all federal environmental regulations as published by the Environmental Protection Agency, 40 CFR (series). Contractor written environmental management and pollution prevention programs shall be reviewed by the Environmental Protection Specialist LT Katherine Voth prior to starting work and must be in accordance with the Unit Environmental Guide. b. Written notification must be provided to the Environmental Protection Specialist of any activity that could potentially cause a permit violation on NCRDF. Some examples of qualifying activities are: any activity that could result in a spill or discharge into a waterway or introducing a hazardous material into the environment. c. Copies of the following must be provided to the Environmental Protection Specialist prior to starting work in affected areas: Material Safety Data Sheets, permits, and notices of intent. d. Hazardous materials used by a contractor are required to be disposed of by that contractor. Disposal must be in accordance with federal, state, and local guidelines. # 11-29-16: Changed NAICS code and classificationo code.

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS