Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Government Contract opportunity from Department Of Defense was posted on December 9, 2015. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

This is a Special Notice Requesting Industry Review & Comments for Planning Purposes and includes the Draft Performance Work Statement (PWS) and Access Instructions to GFI, Parcel 3, Fort Wingate, NM

Closed
W912BV-16-S-1000Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 562910
New
Theatre Mold Remediation Scope of Work
Solicitation # AT25-0006
Solicitation AT25-0006 is a subcontracting opportunity with Adams and Associates, Inc. for comprehensive mold remediation at Theatre Building 1086 of the Atterbury Job Corps Center in Edinburgh, Indiana. The project was initiated following a sprinkler system failure that caused significant water damage. The scope of work requires the remediation of the entire building, including cleaning visible mold from CMU walls, concrete floors, and vinyl tiles, as well as the removal and replacement of affected drywall, gypsum wallboard, and acoustical tile ceiling finishes. Additionally, the contractor must clean or replace damaged theater seating cushions and perform dehumidification to maintain humidity levels at or below 50 percent. All work must adhere to ANSI/IICRC S520 standards, EPA guidelines, OSHA regulations, and the findings of the Micro Air Inc. Mold Testing report dated April 11, 2024. The contract is a single lump sum award based on best value, with evaluation weights distributed across price (60 points), quality (20 points), past performance (10 points), and schedule (10 points). Key requirements include the provision of a Certified Industrial Hygienist for verification and final clearance, a detailed remediation plan featuring HEPA filtration and negative air pressure, and compliance with Davis-Bacon Act wage determinations. Bidders must hold a valid Indiana Contractor's License and provide proof of automobile and workers compensation insurance, naming Adams and Associates, Inc. as an additional insured. Proposals must be submitted on company letterhead and include a detailed cost breakdown, a timeline for substantial completion, and a 90-day bid guarantee. Work must commence within 14 days of the Notice to Proceed, and payment is issued on Net 30 terms.
Atterbury Job Corps Center

POSTED

about 3 hours ago

DEADLINE

in 10 days

General Info

NAICS

562910 - Remediation Services

Place of Performance

Fort Wingate Depot Activity (FWDA), New Mexico, GALLUP, NM, 87305, USA

Set-Aside

NONE

Documents

1

PWS - FWDA Parcel 3 Closure & Corrective Action

PDF, High priority: read this firstsow
High

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

special-notice

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → W076 Endist Tulsa
Contacts1 person available
OfficeTULSA, OK, 74137-4290, USA
Office AddressTULSA, OK, 74137-4290, USA
Contacts
Brenda K. AndersonContract Specialist

Full Description

Show more
THIS IS A SPECIAL NOTICE REQUESTING INDUSTRY REVIEW AND COMMENTS FOR PLANNING PURPOSES AND INCLUDES THE DRAFT PERFORMANCE WORK STATEMENT (PWS) AND ACCESS INSTRUCTIONS TO GFI. THIS IS NOT AN INVITATION FOR BID (IFB)] OR A REQUEST FOR PROPOSAL (RFP). PLEASE DO NOT SUBMIT A PROPOSAL OR COMPANY QUALIFICATION/INFORMATION. This Special Notice is being issued for the purpose of soliciting industry review and comment on the Draft PWS, and advance dissemination of GFI to potential offerors of the Government's requirement for FWDA Parcel 3 Closure & Corrective Action at Fort Wingate Depot Activity, McKinley County, New Mexico. This Special Notice is to provide information for early planning and does not constitute a commitment, implied or otherwise, that a procurement action will be issued. There is no entitlement to payment by the Government of direct or indirect costs or charges that arise as a result of the provision of this information. Note that official information concerning this Special Notice will be provided by the Contracting Officer only. GENERAL INFORMATION: The US Army Corps of Engineers (USACE), Tulsa District in conjunction with the Defense Base Realignment and Closure Act of 1990 (BRAC), is contemplating a performance-based approach for Closure actions at the Hazardous Waste Management Unit and Corrective Action Management Unit, and Corrective action at other sites within Parcel 3 at Fort Wingate Depot Activity, New Mexico. This effort is a validated FY2016 requirement; however the Government reserves the right to cancel this requirement at any time. Should BRAC determine to proceed with this requirement, it will be procured using FAR Part 15 procedures and will result in a Firm-Fixed-Price (FFP) performance based, "C" type contract. The requirement would be issued as an Unrestricted (i.e., no set-aside) acquisition with a Request for Proposal (RFP) being finalized and posted to FedBizOpps at a later date. A bidder's meeting/site visit is TENTATIVELY scheduled for January 20, 2016 at a meeting site in Gallup, NM; definitive information will be provided with the official RFP. A Request for Proposal is NOT being issued as a result of this Special Notice and has not been issued to-date. PROJECT NARRATIVE: The USACE, Tulsa District is considering a performance-based approach for Closure actions at the Hazardous Waste Management Unit and Corrective Action Management Unit, and Corrective action at other sites in Parcel 3 at Fort Wingate Depot Activity, New Mexico. The period of performance (PoP) is estimated at 8 years from date of contract award. The following information is provided in the single PDF document to assist potential offerors in planning for this requirement: DRAFT Performance Work Statement (PWS), dated 8 December 2015 Industry is invited, but not required, to submit any comments relative to the clarity and content of the PWS or the GFI to the USACE POC identified below. Comments are requested to be provided no later than 22 December 2015. The government will not provide responses to any comments received. GOVERNMENT FURNISHED INFORMATION (GFI): The government has consolidated all currently available GFI. Due to the volume of available site documentation, the government will only provide the electronic GFI via download to contractor-provided external hard drives. To ensure receipt of GFI in a timely fashion it is important to adhere to the following instructions: 1) Contractor must notify the contracting POC identified below via email that they are requesting GFI and provide a company POC. 2) Contractor will arrange delivery of a new, UNOPENED, factory SEALED, Windows PC compatible, minimum 1 Terabyte data capacity, USB connection external hard drive addressed to Mike Scoville, Room 3A12, 819 Taylor St, Fort Worth, TX 76102, Phone: 817/886-1875 as soon as possible. Due to network security reasons, the government will not accept an opened or unsealed hard drive package for downloading GFI. 3) Contractor must provide with their submitted external hard drive their return shipping container and their return shipping instructions to include a pre-paid and addressed label via the carrier of their choice (i.e., FedEx, UPS, etc.). The contractor shall be responsible for retaining the tracking number for the return shipment. NOTE: The Government will not provide return shipping containers or shipping costs. GFI may be requested and hard drives submitted at any time during the time period of this Special Notice. All government furnished information (GFI) electronic files pertaining to the project will be uploaded onto the provided external hard drive and sent to respective contractors in their provided shipping container to assist in their response to the forthcoming RFP. Provided GFI will include past RCRA reports, historical data, photographs, etc. The Fort Wingate RCRA Permit and all attachments are available on the New Mexico Environment Department's website: www.nmenv.state.nm.us, under Hazardous Waste Facilities. Additional information including documents submitted to NMED and FWDA's history can be found on the FWDA website: www.ftwingate.org. Contractors will not have access to government information systems not identified above. GOVERNMENT POINTS OF CONTACT FOR THIS SPECIAL NOTICE: 1) Notification of Request for GFI and submission of industry comments should be emailed directly to: Ms. Brenda Anderson, USACE Contracting Specialist (contact@example.gov). 2) Contractor external hard drives should be shipped to the attention of: U.S. Army Corps of Engineers, Fort Worth District Attn: Mike Scoville (+1 (555) 000-0000) Room 3A12, 819 Taylor St Fort Worth, TX 76102

More opportunities from Department Of Defense → W076 Endist Tulsa

Same awarding agency

NAICS: 237990
New
Federal
Webbers Falls Excitation System Replacements
Solicitation # W912BV26RA029
Solicitation W912BV26RA029 is a Request for Proposal issued by the Department of Defense, specifically the US Army Corps of Engineers Tulsa District, for the design and installation of three excitation systems at the Webbers Falls Powerhouse in Oklahoma. The project scope includes the demolition of existing equipment and the supply of three identical full inverting potential source rectifier exciters, each featuring a rectifier assembly, a power potential transformer, and microprocessor digital controllers capable of operating in high humidity and temperatures up to 40 degrees Celsius. Key deliverables include the hardware, comprehensive O&M data packages, field test reports, spare parts, and training for maintenance personnel. The performance period is 300 calendar days from the date of the notice to proceed. This is a partial small business set-aside under NAICS code 237990. Proposals are evaluated on an acceptable or unacceptable basis across three factors: past performance (requiring experience in specific categories within the last five years), a detailed work plan and schedule, and minimum small business participation percentages, including 16 percent aggregate and 11 percent for small disadvantaged businesses. The contract requires strict adherence to electrical and safety standards such as NFPA 70 and IEEE C2, as well as military standards for shipment and storage. Additionally, the prime contractor must possess a Facility Clearance, and personnel must comply with DoD 8570.01-M training and cybersecurity requirements. Payment requests are to be processed electronically via Wide Area WorkFlow.
Other Heavy and Civil Engineering Construction

POSTED

about 13 hours ago

DEADLINE

in 7 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS