This Combined Synopsis/Solicitation opportunity from Department Of Defense was posted on May 19, 2023. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Trane Chiller Replacement for Facility 431

Closed
FA252123QA0016Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 333415
New
DIBBS
COOLING COIL, AIR, DUCT
Solicitation # SPE7M0-27-T-0178
Solicitation SPE7M0-27-T-0178 is issued by the DLA Weapons Support Maritime Supply Chain ESOC Buys for the procurement of one duct type air cooling coil, identified by NSN 4130011916131 and part number 19-80-2979M. The requirement is classified under NAICS code 333415 and is set aside for small businesses, with a specific price evaluation preference for HUBZone concerns. The original required delivery date is October 1, 2026, with a delivery window of five days after receipt of order. Delivery is FOB Origin, and both inspection and acceptance will occur at the destination, specifically the Puget Sound Naval Shipyard IMF in Bremerton, Washington. The contract mandates strict adherence to technical and quality requirements via the DLA Master List and specifies packaging and marking standards according to MIL-STD-2073-1E and MIL-STD-129. Special restrictions are in place regarding the use of mercury and the removal of government identification from non-accepted supplies. Administrative requirements include electronic invoicing through the Wide Area WorkFlow system and submission of all quotes via the DLA Internet Bid Board System by October 19, 2026. Key regulatory clauses apply, including the Buy American and Balance of Payments Program, NIST SP 800-171 assessment requirements, and safeguarding of covered defense information.
DLA WEAPONS SUPPORT MARITIME SUPPLY CHAIN ESOC BUYS

POSTED

about 15 hours ago

DEADLINE

in 2 days
NAICS: 333415
New
Federal
41--COOLER UNIT,AIR
Solicitation # N0010423QJA97
Solicitation N00104-23-Q-JA97 is a firm-fixed-price request for quotation issued by NAVSUP Weapon Systems Support MECH for the manufacture and delivery of one Air Cooler Unit, identified by NSN 4130-99-555-2016 and Part 50250-04 under Cage Code 4DSJ9. The procurement requires strict adherence to quality and technical standards, including physical identification per MIL-STD-130 and preservation and packaging according to MIL-STD-2073. Government source inspection is mandatory, and all freight is handled as FOB Origin. Delivery is expected within 180 days, with primary shipping directed to the DLA Distribution New Cumberland facility in Pennsylvania. The award will be made to a single responsible offeror based on the most advantageous combination of price and past performance, with past performance weighted as more important than price. Offerors must be authorized distributors of the original equipment manufacturer and provide official verification of this status. Compliance with various federal regulations is required, including Buy American and Trade Agreements, NIST SP800-171 cybersecurity standards, and hazardous material identification per FAR 52.223-3. Invoicing and payment must be processed electronically through the Wide Area Workflow system. The final deadline for the submission of quotes is October 23, 2026, with Sophie Benson serving as the cognizant Contract Specialist.
Navsup Weapon Systems Support Mech

POSTED

about 20 hours ago

DEADLINE

in 4 days

General Info

NAICS

333415 - Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing

Place of Performance

Patrick AFB, FL, 32925, USA

Set-Aside

WOSB

Documents

5

FA252123QA0016 Combined Synopsis/Solicitation Amended

PDF, High priority: read this firstrfq
High

HVAC Chiller System Justification and Approval - Air Force

PDF, High priority: read this firstjustification-and-approval
High

RFQ FA252123QA0016 Combined Synopsis/Solicitation for Trane Chiller

PDF, High priority: read this firstrfq
High

Trane Chiller Replacement for Facility 431

PDF, High priority: read this firstsow
High

FA252123QA0016 Questions Answered - Trane Chiller Replacement

PDF, Low priorityq-and-a
Low

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

1 update
PhaseClosed
Posted

Sources Sought

Type Changed

Sources Sought → Combined Synopsis

Notice updated

The notice description changed.

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → FA2521 45 Cons Pk
Contacts2 people available
OfficePATRICK SFB, FL, 32925-3237, USA
Office AddressPATRICK SFB, FL, 32925-3237, USA

Full Description

Show more
NOTICE TO PROSPECTIVE OFFERORS: THIS IS AN AMENDED SOLICITATION Summary of Changes: 1. Questions and Answers. 1.) RFP Section __________ Paragraph _________ SOW/Technical Specification/Drawings paragraph/page ___________ Other (Specify) ___________________________ Question: On delivery of chiller, will my company need to provide a crane for offloading the chiller? Answer: No, because the heavy equipment shop will offload the chiller in the mechanical yard. 2.) RFP Section __________ Paragraph _________ SOW/Technical Specification/Drawings paragraph/page ___________ Other (Specify) ___________________________ Question: If we need to provide this service, how far will the chiller have to be transported to its final delivery position? Is it a simple pick up and set down process from the truck onto the ground or will it need to be moved a certain distance? If it needs to be moved a certain distance, roughly how far? Answer: The heavy equipment shop will complete the transportation of the chiller from the mechanical yard to the building. The HVAC shop will install the chiller in-house. Then, a Trane representative will be there to verify startup. This is a Brand Name requirement for one each TRANE Water-Cooled Chiller. Please see attached CLASS Brand Name Justification & Approval (Brand Name Justification & Approval Redacted). See Combined Synopsis/Solicitation for salient features. The solicitation number FA252123QA0016 is a combined synopsis/solicitation for a commercial end product. This combined synopsis/solicitation is issued as an RFQ in accordance with FAR Part 13. FA252123QA0016 shall be used to reference any written quote provided under this request for quote. Please make quote valid for 60 days from submission. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular. This is a set-aside for Women Owned Small Business (WOSB).

More opportunities from Department Of Defense → FA2521 45 Cons Pk

Same awarding agency

NAICS: 561990
Federal
Lifeguard Services at Patrick Space Force Base
Solicitation # FA252127QB013
Solicitation FA252127QB013 is a 100 percent Small Business Set-Aside for a single-award, firm-fixed price, indefinite-delivery, indefinite-quantity contract to provide lifeguard and aquatics management services at Patrick Space Force Base in Florida. The contractor is responsible for providing all personnel, uniforms, daily supervision, and non-personal services for two specific locations: the Fitness Center Mission Training Pool and the Outdoor Recreation Community Recreation Pool, including its splash pad. The base period of performance runs from November 1, 2026, to October 31, 2027, with four subsequent one-year ordering periods and a final extension option through April 30, 2032. The scope of work includes specialized services such as water survival skills testing, support for Brevard Spring Break, and special youth programs. Operations must adhere to strict regulatory standards, including DAFMAN 48-143, CDC Model Aquatics Health Code, and Florida Administrative Code 64E-9-008. Key operational requirements include water quality testing every two hours and a mandatory 10 minute break for lifeguards every 50 minutes of surveillance. The contractor must maintain liability insurance of 1 million dollars per occurrence and 2 million dollars aggregate, and all personnel must undergo rigorous background checks, including DD Form 2981 for those working with minors. Award will be based on best value, considering technical acceptability, price, and schedule, and may not necessarily go to the lowest priced offeror. Payment will be processed electronically via Wide Area Workflow. Interested offerors must submit technical quotes in PDF or Word format by October 26, 2026, including their Unique Entity Identifier and a statement of agreement with all solicitation terms.
All Other Support Services

POSTED

11 days ago

DEADLINE

in 6 days
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS