TUBE, GAS SAMPLING, VENT
Contract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
AI Contract Overview
The gas sampling tube is designed for use with adult and pediatric intubated patients on ventilators, featuring a built-in 0.2 micron antibacterial filter and a hydrophobic water trap to prevent contamination and moisture buildup. It includes a two-port channel design and long tubing measuring six inches or fifteen centimeters, with universal airway adapters compatible with standard 15 mm or 22 mm endotracheal and tracheostomy tubes, ventilatory circuits, and closed suction systems. The unit is supplied in packs of twenty-five, identified by NSN 6515-01-596-6391, and must comply with rigorous technical and quality specifications outlined in the DLA Master List of Technical and Quality Requirements. Packaging must adhere to DLA standards, and government identification must be removed from non-accepted supplies. The solicitation, issued under SPE2DS-26-T-227K, was posted on July 13, 2026, with responses due by July 20, 2026, and calls for a delivery of three packs within 84 days to APO 09227-0000. The contract is managed by the Department of Defense's Medical Supply Chain under the NAICS code 334511, with Colin Owens listed as the primary point of contact.
General Info
Agency
NAICS
Place of Performance
ATTN CL VIII MED REQ PROCES ACT, APO, AE, 09227-0000, USSet-Aside
Documents
(1)AI Contract Breakdown
Uniform Contract FormatWhat is UCF?
Uniform Contract Format (UCF) uses AI to break down any contract into standardized sections—scope, pricing, deliverables, and evaluation criteria.
Timeline
Response Deadline
Organization & Contact Information
Full Description
TUBE,GAS SAMPLING, VENTILATOR,,
ADULT AND CHILD; SAMPLING LINE WITH AIRWAY
ADAPTER VITALINE H SET ADULT PEDIATRIC 25S; CO2
SAMPLING LINE WITH AIRWAY ADAPTER; FOR ADULT AND
PEDIATRIC INTUBATED PATIENTS; 0.2 MICRON
ANTIBACTERIAL FILTER; BUILT-IN WATER TRAP WITH
HYDROPHOBIC FILTER; 2-PORT CHANNEL DESIGN; LONG
TUBING (6 IN/15 CM); UNIVERSAL AIRWAY ADAPTERS
CONNECT TO 15 MM OR 22 MM ENDOTRACHEAL OR
TRACHEOSTOMY TUES, VENTILATORY CIRCUITS, CLOSED
SUCTION SYSTEMS, AND OTHER DEVICES
UNIT OF ISSUE: PG/25 EACH
..
RA001: THIS DOCUMENT INCORPORATES TECHNICAL AND/OR QUALITY REQUIREMENTS
(IDENTIFIED BY AN 'R' OR AN 'I' NUMBER) SET FORTH IN FULL TEXT IN THE
DLA MASTER LIST OF TECHNICAL AND QUALITY REQUIREMENTS FOUND ON THE WEB
AT:
http://www.dla.mil/HQ/Acquisition/Offers/eProcurement.aspx http://www.dla.mil/HQ/Acquisition/Offers/eProcurement.aspx
FOR SIMPLIFIED ACQUISITIONS, THE REVISION OF THE MASTER IN EFFECT ON THE SOLICITATION ISSUE DATE OR THE AWARD DATE CONTROLS. FOR LARGE ACQUISITIONS, THE REVISION OF THE MASTER IN EFFECT ON THE RFP ISSUE DATE APPLIES UNLESS A SOLICITATION AMENDMENT INCORPORATES A FOLLOW-ON REVISION, IN WHICH CASE THE AMENDMENT DATE CONTROLS.
..
RD003, COVERED DEFENSE INFORMATION POTENTIALLY APPLIES
..
RP001: DLA PACKAGING REQUIREMENTS FOR PROCUREMENT
..
RQ011: REMOVAL OF GOVERNMENT IDENTIFICATION FROM NON-ACCEPTED SUPPLIES
..
ADEQUATE DATA FOR THE NSN/Part Number: 6515-01-596-6391 Quantity: 3 PG Purchase Request: 7017475159QTY: 3 Delivery: 84 days ADO