Upgrade Fire Alarm System

Closed
15B11124A0000021Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

General Info

Agency

Department Of Justice → Fci MemphisView Agency

NAICS

92216

Place of Performance

Memphis, TN, 38134, USA

Set-Aside

SBA

Documents

(1)

15B11124A0000021+Upgrade+Fire+Alarm.pdf

PDF

AI Contract Breakdown

Uniform Contract Format

What is UCF?

Uniform Contract Format (UCF) uses AI to break down any contract into standardized sections—scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

Solicitation

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Justice → Fci Memphis
Contacts2 people available
OfficeMEMPHIS, TN, 38134, USA
Organization / Agency
Department Of Justice → Fci Memphis
View Agency Profile
Office AddressMEMPHIS, TN, 38134, USA

Full Description

Show more
The Federal Correctional Institution Memphis, TN, is a facility housing 862 low-security inmates within a secure perimeter. The current Edwards EST3 Fire Alarm System at FCI Memphis is unreliable and problematic. The system consists of 13 fire alarm panels, 1 annunciator, and 910 devices, including smoke detectors, heat detectors. pull stations, horn strobes, water flow switches, tamper alarms, magnetic fire control doors, and duct detectors. There are networking problems that prevent communication between panels. The fire alarm panels are configured in a loop/ring topology, causing system disruptions when one panel goes offline. The system experiences Class A and B network failures, multiple ground faults, fail-safe activations, data cards not synchronized with CPUs, and Rail module indicator issues. Due to its age, the system, including LS cards and smoke heads, is outdated and cannot communicate or be repaired. Building 1 currently has a few pull stations and strobes connected to booster system. Single-mode fiber has been installed throughout the institution in a star configuration, running to the main panel in the Communication Server Room, except for Unicor Warehouse 2. The plan is to use the new fiber to connect all panels to the main pancel, with LC patch connectors linking the established fiber to the existing panels. If the system is upgraded to EST4, only the CPU and fiber card installations will be needed using the same devices.

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 650+ contractors already using CLEATUS