Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Government Contract opportunity from Department Of Defense was posted on August 14, 2020. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

UPS Replacement

Awarded
W912EK20P0098Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

General Info

Contract Value

$62,411

NAICS

335999 - All Other Miscellaneous Electrical Equipment and Component Manufacturing

Place of Performance

Rock Island, IL, 61201, USA

Set-Aside

SBA

Award Issued Date

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseAwarded
Posted

special-notice

Awarded

Contract was awarded

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → W07V Endist Rock Island
Contacts1 person available
OfficeROCK ISLAND, IL, 61299-5001, USA
Office AddressROCK ISLAND, IL, 61299-5001, USA

Full Description

Show more
The U.S. Army Corps of Engineers (USACE), Rock Island District (MVR), intends to procure this requirement on a sole source basis in accordance with the statutory of 10 U.S.C. 2304(c)(1) as implemented by FAR 13.106-1(b)(1)(i), Purchases not exceeding the simplified acquisition threshold and only one source reasonably available. The USACE, MVR intends to award a commercial, firm fixed price purchase order to Nationwide Power Solutions, Inc., 1060 Mary Crest Rd, Henderson, NV, 89074-7818. The NAICS code for this procurement is 335999 with a size standard not to exceed 500 employees. THIS NOTICE IS NOT A REQUEST FOR COMPETITIVE QUOTES and no solicitation will be issued; however, any SAM registered business that believes it can meet the requirement may give written notification to the contract specialist (information provided below) by 21 July, 2020 at 10:00 M CST. Capability statements must be furnished in sufficient detail to demonstrate the ability to comply with the requirement listed. A determination by the Government not to compete this proposed contract based on responses to this notice is solely within the discretion of the Government. Information received will be considered solely for the purpose of determining whether to conduct a competitive procurement. The USACE, MVR, will not reimburse for any costs connected with supplying sufficient detail to demonstrate the ability to comply with the requirement listed. In order to receive a government award, a firm must be registered in the System for Award Management Database (SAM) at www.beta.sam.gov. Firms must register on a one-time basis, and annually confirm accuracy and completeness of registration information. Questions and capability statements should be directed to Elizabeth Williams at +1 (555) 000-0000; email: contact@example.gov REQUIREMENTS SUMMARY The USACE, Clock Tower Complex, seeks to procure a UPS replacement and maintenance bypass circuit. The requirement shall include the replacement of the existing uninterruptible power supply (UPS) with new UPS system and install a free standing maintenance bypass. The Contractor shall provide all electrical work needed for a full and complete install. The Contractor shall remove and install the UPS and maintenance bypass from Friday after 6:00 pm to Sunday 6:00 pm, with the completion date to be no later than 60 calendar days from date of contract award. Contractor shall adhere to all security measures and comply with the safety regulations of EM 385-1-4 2014 version for all on-site work at the Clock Tower Complex. UPS SYSTEM DESCRIPTION The performance of the UPS must not be degraded when operating without a system battery, provided the input AC source is within tolerance. Redundant System; Two or more UPS modules, of the same size, on-line, operating in parallel, with more capability than is required to support the total load. If any unit fails, the remaining unit or units is able to support the critical load. Provide an UPS system that conforms to UL 1778 Scalable Unit Internal Redundant. Internal Redundant: scalable unit consists of a UPS system module with more than one (1) power module. There is at least one additional power module that is not required to handle the load within the system. The additional power module or power modules can be sized to handle only part of the critical load or all the critical load. Provide an UPS that complies with and is labeled compliant, with FCC Part 15, Subclass B, Class A. Provide Communication card. Furnish the services of competent instructors to give full instruction to designated Government personnel in the adjustment, operation, and maintenance of the specified systems and equipment, including pertinent safety requirements as required. Drawings are to include the following: Detail drawings consisting of a complete list of equipment and materials, manufacturer's descriptive and technical literature, installation instructions, single-line diagrams, elevations, layout drawings, and details required to demonstrate that the system has been coordinated and will function properly as a unit. MAINTENANCE BYPASS CIRCUIT Interlock: Electrically and mechanically interlock the switch (es) to prevent interrupting power to the load when switching to bypass mode. Key interlock requires unlocking bypass/isolating switch before switching from normal position with key that is released only when the UPS is bypassed by the static bypass transfer switch. Lock is designed specifically for mechanical and electrical component interlocking. Load Transfer: The maintenance bypass switch provides the capability of transferring the critical load from the UPS static bypass transfer switch to maintenance bypass and then back to the UPS static bypass transfer switch with no interruption to the critical load ELECTRICAL WORK Receive and unload the new UPS equipment. Remove the existing cage and gate to facilitate removal and installation of the UPS equipment. Disconnect the existing conduits and wiring to the UPS/Bypass equipment. Remove the existing UPS equipment and install the new Bypass Panel. Bypass to be installed during this outage. Bypass Panel to be floor mounted in the approximate location of the existing UPS lineup. Install the two (2) UPS sections in the approximate location of the existing UPS equipment. Relocate the existing conduits and wiring to the new UPS lineup. Install the interconnecting assemblies between sections of the UPS equipment. The work to be coordinated with the owner's representative. All outages shall be performed on Sundays (double time). This will require two (2) outages to accomplish all the work. After the first outage the owner will have to operate on the bypass of the UPS unit until the second outage can be scheduled.

More opportunities from Department Of Defense → W07V Endist Rock Island

Same awarding agency

NAICS: 236220
New
Federal
88th RD US ARMY RESERVE CENTER MONCLOVA, OH CONSTRUCT STORAGE BUILDING AND REPAIR MEP LOTS
Solicitation # W912EK27BA011
The U.S. Army Corps of Engineers, Rock Island District, is soliciting bids for a firm-fixed-price construction project at the 88th RD US Army Reserve Center in Monclova, Ohio. The scope of work involves the construction of an approximately 4,590-square-foot heated pre-engineered metal storage building and the repair of Military Equipment Parking lots. Key construction elements include the installation of insulated metal walls and roofing, overhead and hollow metal doors, cage partitions, and steel shelving. The project also encompasses comprehensive site work, including earthwork, asphalt and concrete placement, chain link fencing, and utility installations for gas, water, and electricity. Building systems will include a wet sprinkler fire suppression system, fire alarms, mass notification systems, and natural gas unit heaters designed to maintain a temperature of 55 degrees Fahrenheit. This is an 8(a) competitive invitation for bid with a performance period of 300 consecutive calendar days. The base bid covers the primary construction and repairs, while Option A provides for concrete footers and Option B allows for the addition of a fifth bay to the storage building. Bids must be submitted in searchable Adobe PDF format via the PIEE Solicitation Module by 11:00 AM Central Time on November 20, 2026. A mandatory prebid meeting was scheduled for November 4, 2026. The contract requires adherence to EM 385-1-1 (2024) safety standards, Davis-Bacon Act wage requirements, and specific cybersecurity protocols under DFARS 252.204-7012. Awardees must provide performance and payment bonds and hold a preconstruction conference within 35 calendar days of the award.
Commercial and Institutional Building Construction

POSTED

3 days ago

DEADLINE

in 22 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS