Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Combined Synopsis/Solicitation opportunity from Department Of Homeland Security was posted on March 11, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

USCG Station Tawas Fire Main Pipe Rupture Repair

Closed
70Z03026QCLEV0033Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 237110
New
Morgans Branch Force Main and Pump Station Improvements
Solicitation # SRP-W-134-0290
The Morgans Branch Force Main and Pump Station Improvements project, solicitation number SRP-W-134-0290, is a construction contract for the City of Belmont, North Carolina, with an estimated value of 16,690,000 dollars. The scope of work involves the construction of 16,435 linear feet of new 20-inch ductile iron force main and comprehensive upgrades to the Morgans Branch Pumping Station. Key infrastructure improvements include the installation of a new wet well, valve vault, and associated appurtenances, as well as the demolition of existing pumps and piping. The contractor is responsible for delivering a fully operational facility, including the installation of pumps, a generator, odor control equipment, new gravity sewers, and manholes, while managing by-pass pumping, testing, and commissioning. The contract will be awarded to the responsible bidder submitting the lowest responsive bid, with a strong emphasis on MWBE compliance through the submission of Good Faith Efforts and Table A documentation. Bids are due by November 12, 2026, and must be submitted using the EJCDC C-410 Bid Form. The project is governed by EJCDC standard general and supplementary conditions, requiring performance and payment bonds and proof of insurance. Technical standards include AWWA Specification C-600 for pipelines, NEMA MG1 for motors, and AWS D1.2 for aluminum welding. Project administration is managed by the City of Belmont with Willis Engineers serving as the project engineer. Payment is processed via Applications for Payment, with terms set at 30 days after presentation to the owner.
Don Moorhead Construction, Inc.

POSTED

about 9 hours ago

DEADLINE

in 20 days

AI Contract Overview

Show more

The contract addresses the urgent repair of a rupture in the underground fire main system along with the replacement of a failed associated valve at the U.S. Coast Guard Station Tawas in East Tawas, Michigan. The scope includes excavation, removal, installation, testing, and restoration of the fire main piping and valve, with the contractor responsible for providing all necessary materials, labor, equipment, and supervision, except for designated government-furnished resources. The work must be completed within 14 calendar days from award, primarily during weekday hours between 7:30 AM and 2:00 PM EST, and requires regular progress reporting and coordination with the Contracting Officer’s Representative to ensure adherence to performance and safety standards. This procurement is issued as a total small business set-aside under NAICS code 237110 (water and sewer line and related structures construction) and is managed by the Department of Homeland Security, Base Cleveland office. The Request for Quotation (RFQ) details submission deadlines, pricing instructions, FAR compliance requirements, invoice procedures via the Invoice Processing Platform, and specifies adherence to the relevant wage determinations for Iosco County, Michigan, per the Davis-Bacon Act. The contract emphasizes timely execution, quality workmanship, and strict conformity to the Statement of Work to restore critical fire protection infrastructure at the Coast Guard facility. Key contacts for the contract are Adam L. Nalewyko and Kara Davis.

General Info

Urgent fire main repair and valve replacement at Coast Guard Station Tawas, 14-day completion required.

Contract Value

$49,850

NAICS

237110 - Water and Sewer Line and Related Structures Construction

Place of Performance

East Tawas, MI, 48730, USA

Set-Aside

SBA

Award Issued Date

Documents

4

RFQ 70Z03026QCLEV0033 Fire Main Rupture Repair USCG Station Tawas

DOCX, High priority: read this first26 pages · rfq
High

Station Tawas Fire Main Piping and Valve Replacement SOW 2026

DOCX, High priority: read this first4 pages · sow
High

Wage Determination MI20250126 for Iosco County, MI Building Construction

TXT, High priority: read this first6 pages · wage-determination
High

Tawas+FM2.mov

MOV

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

PhaseClosed
Posted

Combined Synopsis

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Homeland Security → Base CLEVELAND(00030)
Contacts2 people available
OfficeCLEVELAND, OH, 44199, USA
Office AddressCLEVELAND, OH, 44199, USA

Full Description

Show more

U.S. Coast Guard Station Tawas, Tawas, MI, has experienced a rupture  in the underground fire main system along with the failure of an associated valve.  Repair is required in accordance with the attached RFQ and SOW.

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS