The project at 7877 Woodley Avenue and 16139 Stagg Street in Van Nuys, California, involves the implementation of a soil vapor extraction (SVE) system as an interim remedy to address trichloroethylene (TCE) contamination in soil vapor within the OU-3/Plume 3 area of the Van Nuys Airport Industrial Center. Historically used for industrial and commercial purposes including manufacturing, warehousing, and automotive repair, the site is currently zoned for similar use and has no ecological habitat value. Investigations conducted between 2020 and 2024 confirmed TCE as the primary contaminant, with concentrations peaking at depths up to 110 feet below ground surface and originating from on-site sources rather than off-site migration. The work is being carried out under a Standard Voluntary Agreement between the California Department of Toxic Substances Control (DTSC) and Rexford Industrial Realty, Inc., with the goal of achieving a No Further Action determination. The SVE system will utilize seven existing extraction wells and include a 500 SCFM rotary lobe blower, a knock-out tank, a heat exchanger, and two 2,000-pound vapor-phase activated carbon units, all installed in the northwestern parking lot of 7877 Woodley Avenue. The system is designed to remove and treat contaminated vapor to prevent emissions to the atmosphere and mitigate potential vapor intrusion into adjacent structures. Operation is governed by a 12-month SCAQMD permit, with provision for a site-specific permit thereafter, and the system may be expanded with additional wells to the north and east of the 16139 Stagg Street building based on monitored performance. All activities comply with California environmental codes, SCAQMD air quality regulations, and the CEQA Common Sense Exemption, ensuring no adverse impact on nearby sensitive receptors. The project is overseen by DTSC with direct contact through Jose Diaz as Project Supervisor and Gregory Shaffer as Branch Chief, and performance is limited to the two specified addresses in Van Nuys, CA 91406. No contract value, pricing, or procurement details are disclosed, and while the work is conducted under regulatory authority, no formal federal acquisition clauses or commercial contracting mechanisms are present in the documentation.
General Info
Agency
NAICS
Place of Performance
7877 Woodley Avenue and 16139 Stagg Street, Van Nuys, CA, 91406Set-Aside