Ventilation Upgrade

Awarded
285-21-RFQ-0011Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

General Info

Contract Value

$145,739.74

NAICS

33341

Place of Performance

Cherokee, NC, 28719, USA

Set-Aside

NONE

Award Issued Date

Documents

2

285-21-RFQ-0011+VENTILATION+UPGRADES_Extension.pdf

PDF

285-21-RFQ-0011+VENTILATION+UPGRADES.pdf

PDF

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

2 updates
PhaseAwarded
Posted

Combined Synopsis

Notice updated

Response deadline changed from Apr 30, 2021 to May 15, 2021. The notice description changed.

Deadline changed

Response deadline changed from May 15, 2021 to May 14, 2021.

Awarded

Contract was awarded

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Health And Human Services → Nashville Area Indian Health Svc
Contacts2 people available
OfficeNASHVILLE, TN, 37214, USA

Full Description

Show more
This solicitation has been extended by 15 days. Proposals can be submitted on May, 15, 2021 by 11:30am CST. Conditioned Fresh Air Supply Replace Existing AAON RM-010-8-0-AA02-152 Outdoor air handling unit with a new unit capable of delivering 6,000 CFM. Unit shall provide sufficiently dry air that the internal relative humidity stays at or below 50% at a temperature of 70 degrees, F. The existing ductwork supplies Fan Coil Units 1 to 21 most being located on the first floor of the building. Additional supply ducting shall be added to provide conditioned air to the basement air handler AHU-3 (intake is located behind existing AAON unit). Remove any existing lovers/obstructions in the exterior wall. SEE STATEMENT OF WORK SECTION FOR FURHTER DETAILS. Isolation Room (Rooms 111 & 113) Add inline Exhaust Fan capable of removing 150 CFM from each room. It is suggested to connect into the return air ducting accessible from the main corridor. If that is not possible ceilings in bedrooms are a false ceiling. True ceiling is a few feet higher. Any additional return grills added must be tamper resistant and supported by the structure holding the true ceiling. Exhaust shall be vented through the roof and shall be constructed to match existing. Existing exhaust fans in the facility are made by Cook model numbers 70 SQN and 80 DB. Exhaust Fan shall be connected to the Building Automation System with status displayed on the Exhaust Fan screen with the ability to override the unit to an off status.

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS