Vista Housing for Seniors - Invitation to Bid - Fire Alarm System Upgrade

Closed
AB-2026-03448Canada

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 238210
New
SLED
Elevator Lobby 2 Way CommunicationsThe contract involves the installation of 23 new two-way communication boxes in elevator lobbies across the terminal, including 17 passenger elevators, three service elevators, and three ramp landing elevators. The work is part of an Aviation Project Management Group initiative under the Port of Seattle, aimed at enhancing safety and communication access in all elevator areas. The project falls under NAICS code 238210, indicating it is classified as electrical contracting work, and the scope requires precise placement and integration of communication equipment outside each elevator to meet accessibility and operational standards. No set-aside provisions are specified, and the contract is currently in forecast status with a posted date of July 7, 2026, suggesting it is not yet open for bidding but anticipated for future solicitation. Primary point of contact for inquiries is Angela Peterson, reachable via phone or email, with Christina Burdett serving as the project manager for technical coordination. The place of performance is at the Port of Seattle facilities, though specific city or zip details are not provided in the data. All work must be completed in accordance with facility requirements and industry safety codes for emergency communication systems. Interested parties should monitor the provided UI link for official solicitation release, as no formal solicitation number has been assigned yet.
Aviation Project Management Group

POSTED

21 minutes ago

DEADLINE

N/A
NAICS: 238210
New
SLED
Variable Frequency Drives (VFD) Replacement Phase 3 (DBB)The Port of Seattle is preparing to replace the remaining 125 failing Robicon variable frequency drives (VFDs) as part of Phase 3 of its VFD replacement initiative. This effort will involve the complete removal of outdated units and the installation of new VFD equipment designed to improve operational efficiency and reliability. The new VFDs will be fully integrated into the Port’s Direct Digital Controller (DDC) system to enable real-time monitoring of energy usage, output control, and overall system performance. Comprehensive services including wiring, testing, commissioning, and all necessary ancillary equipment will be provided to ensure a fully functional and optimized system upon completion. The work falls under NAICS code 238210 and is managed by the Aviation Facilities & Infrastructure division of the Port of Seattle. Primary point of contact for the project is Yanet Maldonado, reachable via email or phone, with Sharon Miick serving as the project manager for coordination and oversight. The solicitation was posted on July 7, 2026, and is classified as a forecast indicating upcoming procurement activity. While specific details such as place of performance and set-aside information are not yet defined, the scope is focused exclusively on the VFD replacement and integration at Port facilities. Contractors will be expected to deliver a turnkey solution that meets all technical and operational requirements for seamless system performance under the Port’s infrastructure standards.
Aviation Facilities & Infrastructure

POSTED

21 minutes ago

DEADLINE

N/A
NAICS: 238210
New
SLED
Operational Security Cameras Bagwell and North Cargo AreasThe contract entails the design, permitting, and construction of a new security camera system across the Bagwell and North Cargo Operations areas at the Port of Seattle, with the goal of enhancing surveillance capabilities for forensic investigations and stronger enforcement of port movement regulations. The project will replace and expand existing coverage by deploying 50 high-resolution cameras at 43 distinct locations, focusing on critical pathways including main terminal drive lanes and entrances that currently lack adequate monitoring. While current systems primarily target conveyor systems and security doors, the new installation will significantly broaden observational reach, particularly along high-traffic and high-risk zones. In the North Cargo operations area, the system will incorporate flexible Pan Tilt Zoom camera units to deliver dynamic, user-controlled monitoring over large surface areas, bridging gaps in coverage that fixed cameras cannot address. This deployment is designed to ensure comprehensive surveillance while maintaining operational adaptability. The work is managed by the Aviation Project Management Group under the Port of Seattle, with primary contact information provided through Angela Peterson and Project Manager Randa Williams. The project, categorized under NAICS code 238210 for electrical and other wiring installation contractors, is forecasted for future solicitation with no set-aside designation specified.
Aviation Project Management Group

POSTED

21 minutes ago

DEADLINE

N/A

AI Contract Overview

Show more

The project involves replacing the entire existing fire alarm system with a new addressable, single-stage system, including the removal and replacement of all related wiring, devices, and infrastructure. New raceway systems using wire-mold and EMT conduit will be installed throughout the facility, with wire-mold used in residential suites to maintain aesthetics and EMT conduit permitted in mechanical, electrical rooms, and public hallways. All removed materials, including fire alarm detection devices containing radioactive components, must be properly disposed of through certified recycling and environmentally compliant processes, with waste management certificates required for project acceptance. The auto dialer will be upgraded to meet current ULC standards, and the contractor will work with the owner to select the monitoring vendor. Notification devices within suites will be enhanced to include both visual and audible alerts to improve accessibility and safety. The contractor is responsible for securing all necessary building, electrical, and fire permits and must adhere to strict safety protocols under OH&S and WCB regulations. A fire watch is mandatory whenever the existing system is disabled during installation. Smoke alarms inside suites must be replaced with new, code-compliant units. Integration testing, as per CAN/ULC S575, is required and includes coordination and verification with adjacent systems: HVAC shutdown interfaces, auto dialer connections, fire suppression systems, emergency generators, elevator recall functions, and magnetic door releases. Three days are allocated for system verification, and all work must be completed with minimal disruption while ensuring full compliance with applicable codes and safety requirements.

General Info

Replace fire alarm system with new addressable setup, install conduit, upgrade auto dialer, ensure accessibility, comply with codes, and conduct integration testing.

Agency

Government of Canada → Vista Housing for SeniorsView Agency

NAICS

238210 - Electrical Contractors and Other Wiring Installation ContractorsView NAICS

Place of Performance

Alberta, CAN

Set-Aside

NONE

Documents

(0)

No documents available

AI Contract Breakdown

Uniform Contract Format

No contract breakdown available.

Cannot generate Contract Breakdown because no documents were found from this contract's source.

Timeline

PhaseClosed
Posted

Solicitation

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyGovernment of Canada → Vista Housing for Seniors
Contacts1 person available
OfficeN/A
Organization / Agency
Government of Canada → Vista Housing for Seniors
View Agency Profile
Office AddressN/A
Contacts
JAY ALCABEDOSContracting Authority

Full Description

Show more
SCOPE OF WORK SUMMARY: THIS PROJECT INVOLVES REPLACING THE EXISTING FIRE ALARM SYSTEM, RELATED DEVICES, AND WIRING WITH A NEW ADDRESSABLE, SINGLE-STAGE FIRE ALARM SYSTEM. EXISTING WIRING SHALL BE REPLACED WITH NEW WIRING. A NEW WIRE-MOLD AND EMT RACEWAY SYSTEM SHALL BE INSTALLED THROUGHOUT THE FACILITY. EMT CONDUIT MAY BE USED INSIDE MECHANICAL AND ELECTRICAL ROOMS AND THROUGH THE PUBLIC HALLWAYS. WIRE-MOLD RACEWAYS SHALL BE USED INSIDE RESIDENTIAL SUITES WHERE RACEWAYS ARE EXPOSED. REMOVED MATERIAL SHOULD BE DISPOSED OF AS REDUNDANT CONSTRUCTION MATERIAL AT AN APPROVED RECYCLING FACILITY. FIRE ALARM DETECTION DEVICES CONTAIN RADIOACTIVE MATERIAL AND SHALL BE DISPOSED OF IN AN APPROVED, ENVIRONMENTALLY FRIENDLY PROCESS. DOCUMENTATION OF WASTE MANAGEMENT CERTIFICATES IS REQUIRED FOR FINAL APPROVAL AND ACCEPTANCE. THE CONTRACTOR WILL UPGRADE THE AUTO DIALER TO MEET CURRENT ULC STANDARDS FOR MONITORING AND WILL COORDINATE WITH THE OWNER TO SELECT THE VENDOR. NOTIFICATION DEVICES WILL BE UPGRADED AND ADDED WITHIN THE SUITES FOR VISUAL AND AUDIO ALERTS. THE CONTRACTOR SHALL APPLY FOR BUILDING, ELECTRICAL AND FIRE PERMITS. THREE DAYS HAVE BEEN ALLOWED FOR THE VERIFICATION. CODE REQUIRES A FIRE WATCH WHENEVER THE FIRE ALARM SYSTEM IS DISABLED. SMOKE ALARMS INSIDE THE SUITS SHALL BE REPLACED WITH NEW UNITS AS SPECIFIED. THIS WORK MUST BE COMPLETED WITH CLOSE ATTENTION TO SAFETY REQUIREMENTS REGARDING OH&S REQUIREMENTS AND WCB. SYSTEMS IMPACTED BY INTEGRATION TESTING: THE FOLLOWING SYSTEMS AND RELATED TRADES ARE PART OF THIS CONTRACT FOR THE INTEGRATION TESTING AND VERIFICATION OF THE FIRE ALARM SYSTEM AS PER CAN/ULC S575 COMMISSIONING OF LIFE SAFETY & FIRE PROTECTION SYSTEMS: a) EXISTING HVAC UNITS’ SHUTDOWN INTERFACE. b) AUTO DIALER INTEGRATION AND CONNECTIONS TO THE FIRE ALARM PANEL. c) FIRE SUPPRESSION SYSTEM. d) EMERGENCY GENERATOR. e) ELEVATORS LIFT SYSTEMS RECALL. f) MAGNETIC DOORS RELEASE.