Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, December 9 at 2:00 PM ET

Register Free →

This Award Notice opportunity from Florida was posted on October 29, 2024. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Wakulla County, Panacea Lift Stations, Infrastructure Retrof

Awarded
H1129State & Local

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

This Hazard Mitigation Grant Program project, managed by the Florida Executive Office of the Governor under solicitation H1129, focuses on the infrastructure retrofit of four sewage lift stations in Panacea, Wakulla County. The primary objective is to protect critical sewage services from coastal flooding and hurricane-force winds by installing elevated platforms for control and power panels. Additionally, three of the sites will undergo hardening measures, including the installation of waterproof hatches, raised wet well lids, and the replacement of above-grade valves with corrosion-resistant stainless steel. The project aims to prevent equipment failure and sewer overflows by ensuring all components are protected against a 500-year flood event and comply with National Flood Insurance Program requirements. All installations must meet ASCE 7 standards for wind resistance and anchoring. The work must be executed in strict accordance with all applicable federal, state, and local rules and regulations to ensure the continued operation of essential services during extreme weather events.

General Info

Retrofitting four Panacea sewage lift stations for flood and hurricane resistance per standards.

Contract Value

$940,695.57

NAICS

N/A

Place of Performance

FL, USA

Set-Aside

NONE

Award Issued Date

Contract End Date

October 31, 2027

Documents

1
PDF

Read the document

Every page of every file, in your free workspace.

Read the document

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Ask CLEATUS

I've read this contract. Ask me anything.

Timeline

PhaseAwarded
Posted

Award Notice

Awarded

Contract was awarded

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyFlorida → Executive Office Of The Governor
ContactsNo contacts available
OfficeN/A
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
As a Hazard Mitigation Grant Program project, the Sub-Recipient proposes infrastructure retrofit action to four (4) sewage lift stations located within Panacea, Wakulla County, Florida 32346. The proposed scope of work shall design and install an elevated platform at four (4) sewage lift stations to elevate control and power panels above the base flood elevation and withstand wind velocities and hydraulic forces that can accompany hurricanes. The scope of work also includes retrofit hardening of three (3) of the sites which shall include the installation of a waterproof hatch, raising the wet well lid, and replacing current above grade valves with stainless steel to prevent corrosion. These lift stations are currently unprotected and vulnerable to coastal flooding which can destroy control equipment and lead to a loss of service and sewer overflow affecting the community. This project shall decrease the risk of failure due to flooding damaging equipment at the lift stations and allow the lift stations to continue to maintain service and operate during flood events. All project components shall be protected against a 500-year flood event by implementing specific activities or by locating them outside the Special Flood Hazard Area (SFHA), comply with applicable National Flood Insurance Program (NFIP) requirements and shall be protected against wind with a rated enclosure and appropriate anchoring based on its location requirements per ASCE 7 standards, as applicable. Activities shall be completed in strict compliance with Federal, State and Local applicable Rules and Regulations.

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS