Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, December 9 at 2:00 PM ET

Register Free →

This Solicitation opportunity from South Carolina was posted on August 17, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Wastewater SCADA System HMI Replacement

Closed
State & Local
Submission Closed
Solicitation #
2026-RFP-006

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

Greenwood Metropolitan District is soliciting proposals for the replacement and upgrade of the Supervisory Control and Data Acquisition (SCADA) Human Machine Interface (HMI) systems at the Wilson Creek and West Alexander Wastewater Treatment Facilities. The project aims to modernize existing Wonderware and Allen-Bradley PLC-based architectures by migrating to a client/server configuration, replacing workstation and server hardware, and updating SCADA software to improve operational efficiency, reliability, and user experience. The scope includes design, hardware installation, and the removal of old SCADA cabinets. A mandatory site visit at both facilities is required by September 9, 2026, and proposals must be submitted electronically via the GMD online supplier portal by September 23, 2026, at 4:00 pm. Qualified contractors must provide a bid bond of at least 5 percent of the total bid amount, and the successful awardee will be required to furnish performance and payment bonds. Award selection is based on a best-interest determination considering price, service, safety, quality, and dependability, rather than price alone. The contractor must undergo a rigorous acceptance process involving unit, integration, system, and user acceptance testing, as well as a performance demonstration under real-world operational loads.

General Info

Greenwood Metropolitan District seeks SCADA HMI system upgrades at two wastewater treatment facilities.

NAICS

N/A

Place of Performance

SC, USA

Set-Aside

NONE

Documents

11
PDF, High priority: read this firstrfp
High
PDF, High priority: read this firstrfp
High
PDF, High priority: read this first2 pages · bid-form
High
PDF, High priority: read this firstsow
High
DOCX, Low prioritybid-bond
Low
DOCX, Low prioritypayment-bond
Low
DOCX, Low priorityperformance-bond
Low
PDF, Low priorityother
Low
PDF, Low priorityother
Low
PDF, Low priorityother
Low
PDF, Low priorityscada-hmi-screens
Low

Read all 11 documents

Every page of every file, in your free workspace.

Read the documents

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

View Full Breakdown

Solicitation requirements

6 mandatory

6 requirements in 2 areas

  • Compliance5 · 5 must
    002

    Performance Bond Obligations

  • Eligibility1 · 1 must
    001

    Surety Company Eligibility

  • 4 more requirements, each with its source quote

Read every requirement with its source and proposal context.

Read all 6 requirements

Ask CLEATUS

I've read this contract. Ask me anything.

Timeline

PhaseClosed
Posted

Solicitation

Response Deadline

Deadline has passed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencySouth Carolina → WILSON CREEK
Contacts2 people available
OfficeGreenwood, SC, 29646, USA

Interested Companies (32)

AdaptaspaceCalgary, Alberta
Blacktip SolutionsIndian Land, SC
Blue GroupTwin Falls, ID

See All 32 Interested Companies

Get full access to view all interested companies, their contact details, and full contractor profiles.

Get full access

Full Description

Show more
GMD is issuing this Request for Proposal (RFP) to solicit qualified system integrator contractors for the upgrade of its Supervisory Control and Data Acquisition (SCADA) Human Machine Interface (HMI) system. The upgrade aims to improve operational efficiency, system reliability and user experience of the SCADA systems at both facilities. This RFP outlines the scope of work, proposal requirements and evaluation criteria for a replacement SCADA HMI System at the Wilson Creek Wastewater Treatment Facility, and the West Alexander Wastewater Treatment Facility. A mandatory site visit will be required at both wastewater treatment facilities prior to the deadline specified within this RFP. Please email the IT team contacts at Sign up to see this detail and Sign up to see this detail to schedule your site visit. The purpose of the site visits is to respond to any immediate questions respondents may have about this RFP and provide the opportunity for respondents to evaluate site conditions and other considerations necessary for an accurate submittal. Proposals will not be accepted from respondents that cannot be verified as completing a site visit with a member of GMD's IT staff. Locations: Wilson Creek Wastewater Treatment Facility 482 Wilson Creek Road, Greenwood, SC 29646 West Alexander Wastewater Treatment Facility 225 Joe Bernat Drive, Greenwood, SC 29646 Detailed Project Infrastructure: Access to critical infrastructure attachments including detailed system specifications, network diagrams and photographs are available by secure access from GMD's IT team. To receive detailed technical specifications, interested respondents must contact GMD IT Manager Jeff Auman at Sign up to see this detail

Get AI-powered intelligence on the opportunities still open

Every solicitation package arrives shredded into a compliance breakdown and matched to your past performance, with incumbent history and alerts on amendments and award.

Miguel
Hillary
Keith Deutsch
Christine

Join 900+ contractors already using CLEATUS