Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, December 9 at 2:00 PM ET

Register Free →

WOLF CREEK POWERHOUSE BRIDGE CRANE REHABILITATION

Open
W912P527RAXXXFederal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

General Info

NAICS

333923 - Overhead Traveling Crane, Hoist, and Monorail System Manufacturing

Place of Performance

Jamestown, KY, USA

Set-Aside

NONE

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Due in 15 days

Get what you need to respond

No documents were posted with this contract.

  • Buyer contactEmail and phone
  • Original solicitationLink to the source posting
Get the buyer contact

Ask CLEATUS

I've read this contract. Ask me anything.

Timeline

PhaseSources Sought
Posted

Sources Sought

Response Deadline

Submission deadline

Response Deadline

Ready to pursue this opportunity?

Get full access to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → W072 Endist Nashville
Contacts2 people available
OfficeNASHVILLE, TN, 37203-1070, USA

Full Description

Show more

SOURCES SOUGHT / REQUEST FOR INFORMATION (RFI)


MARKET RESEARCH FOR WOLF CREEK POWERHOUSE BRIDGE CRANE REHABILITATION


DISCLAIMER:
 THIS IS A REQUEST FOR INFORMATION (RFI) / SOURCES SOUGHT NOTICE BEING RELEASED PURSUANT TO THE REVOLUTIONARY FEDERAL ACQUISITION REGULATION OVERHAUL (RFO) PART 10: MARKET RESEARCH.


This RFI is issued solely for informational, market research, and planning purposes. It does not constitute an Invitation for Bid (IFB), Request for Quote (RFQ), or Request for Proposal (RFP), nor does it constitute a promise to issue an IFB, RFQ, or RFP in the future. No solicitation document exists at this time. Issuance of this notice does not constitute any obligation on the part of the Government and is not to be construed as a commitment by the Government, implied or otherwise, to issue a solicitation or award a contract. Respondents are advised that the United States Government will not pay for any information or administrative costs incurred in response to this RFI. Proprietary information is not being requested, and respondents should refrain from submitting proprietary or business-sensitive data. Detailed technical specifications and drawings will only be made available upon issuance of a formal solicitation.


1. PURPOSE


The Government is conducting this Sources Sought / RFI in support of market research to identify potential qualified and capable industry partners, including small businesses (Small Businesses, 8(a), HUBZone, Service-Disabled Veteran-Owned Small Businesses [SDVOSB], and Women-Owned Small Businesses [WOSB]). The purpose of this notice is to gain knowledge regarding industry interest, capabilities, technical qualifications, and potential subcontracting arrangements to assist the Government in determining the appropriate acquisition strategy and competition basis.


2. PROJECT SCOPE OF WORK


The contemplated requirement is for a firm-fixed-price standalone contract for the complete rehabilitation of the existing powerhouse bridge crane and incidental related work at the Wolf Creek Powerhouse in Jamestown, Kentucky.


Crane Description:


The existing powerhouse bridge crane is a 250-ton, top-running bridge type crane consisting of two bridge girders and two independent trolleys. Each existing trolley features:


  • One (1) Main Hoist rated at 125 tons
  • One (1) Auxiliary Hoist rated at 25 tons

Major Work Items:


The Contractor will be responsible for furnishing all labor, materials, supervision, engineering, tooling, and equipment required to complete the rehabilitation, which includes, but is not limited to, the following major items:


  1. Safety & Access: Modify personnel access and implement safety improvements to the bridge crane walkways, ladders, and maintenance platforms.
  2. Couplings & Seals: Replace hoist motor output shaft brake wheel coupling seals.
  3. Braking Systems: Replace hoist brake pads and perform comprehensive service to restore proper brake gap and operational torque.
  4. Gearboxes & Lubrication: Clean speed reducers (main hoist, auxiliary hoist, bridge drive, and trolley drive) and replace all lubricating oil; inspect and repair grease lubrication lines; replace main hoist open gear oil.
  5. Wheel & Axle Assemblies: Modify bridge and trolley wheel assemblies to replace original wheel bushings with new anti-friction roller bearings. (Note: The Contractor may have the option to replace entire wheel and axle assemblies or modify and reuse existing wheels and axles).
  6. Below-the-Hook Devices: Provide new, and perform non-destructive inspection, proof-load testing, and painting of below-the-hook lifting devices.
  7. Drives & Automation: Upgrade all variable frequency drives (VFDs) to Magnetek Series 5 VFDs (or approved system equal).
  8. Electrification & Grounding: Furnish and install a new fourth conductor bar dedicated as a continuous ground conductor; modify existing collectors to connect to the fourth conductor bar.
  9. Operator Cab & Controls: Provide and install a new ergonomic operator’s chair, wireless radio remote controllers, absolute hoist encoders, and high-efficiency LED bridge crane lights.
  10. Safety Instrumentation & Limits: Install load cell weighing devices and displays for both main and auxiliary hoists, along with new heavy-duty limit switches for bridge and trolley travel.
  11. Auxiliary Hoists: Furnish and install a new auxiliary tool hoist and a dedicated personnel rescue hoist.
  12. Testing & Commissioning: Perform full operational testing of all mechanical and electrical features of the crane, followed by 100% rated and 125% rated load tests in accordance with CMAA and OSHA requirements.
  13. Documentation: Develop and deliver a comprehensive new Operation and Maintenance (O&M) Manual integrating all legacy data from the existing manual with new equipment data to serve as a complete standalone guide.
  14. Blocks, Sheaves & Lifting Beams:

  • Provide new main and auxiliary lower load block assemblies.
  • Provide new main and auxiliary upper sheaves and pins.
  • Provide new main hoist lifting beam, rotor lifting device, and turbine shaft lifting device.

15.Crane Runway Rails: Survey and modify existing runway crane rails to correct rail span, elevation, and straightness along the entire runway length.


3. CAPABILITY STATEMENT AND CONTRACTOR SURVEY


Interested firms capable of performing the work described herein are requested to submit a capability package containing the following information:


A. General Information


  1. Company Name:
  2. Physical Address / Mailing Address:
  3. Point(s) of Contact: (Name, Title, Phone Number, and Email Address)
  4. CAGE Code:
  5. Unique Entity Identifier (UEI):
  6. Company Website:

B. Business Size and Socioeconomic Classification


  1. Under NAICS Code 333923 (Size Standard: 1,250 employees), is your firm categorized as a:

  • ☐  Large Business
  • ☐  Small Business

  1. If certified as a Small Business, identify any applicable socioeconomic designations:

  • ☐  Small Disadvantaged Business (SDB) / 8(a)
  • ☐  Historically Underutilized Business Zone (HUBZone)
  • ☐  Service-Disabled Veteran-Owned Small Business (SDVOSB)
  • ☐  Veteran-Owned Small Business (VOSB)
  • ☐  Woman-Owned Small Business (WOSB)
  • ☐  Economically Disadvantaged Woman-Owned Small Business (EDWOSB)

C. Relevant Past Performance / Technical Experience


Submit a minimum of two (2) and up to three (3) relevant projects completed within the past ten (10) years demonstrating experience as a Prime Contractor or Subcontractor performing major rehabilitation, modernization, or installation on heavy industrial hoisting machinery (minimum 100-ton capacity).


Provide the following details for each reference project:


  • Project Title:
  • Contract Number (if applicable):
  • Client / Agency / Customer Point of Contact (Name, Title, Phone, Email):
  • Role (Prime or Subcontractor):
  • Contract Value / Final Dollar Amount:
  • Period of Performance / Completion Date:
  • Self-Performed Work: (Identify the scope/type and percentage of work self-performed based on contract value)
  • Detailed Project Narrative: Include details highlighting specific experience with:
  • Heavy lifting machinery rehabilitation (brakes, gears, sheaves, and wheel assemblies)
  • Crane electrification, Magnetek or modern crane-duty VFD retrofits, encoders, and radio controls
  • Runway rail realignment/surveying and proof-load testing up to 100% and 125%

D. Subcontracting and Execution Strategy


  1. In accordance with RFO 52.219-14 (Limitations on Subcontracting), what estimated percentage of the total contract value would your firm perform directly (self-perform)?


       2. What specific scopes of work do you anticipate subcontracting out (e.g., rail surveying, machining, electrical, painting,     


           testing)?



          3. If your firm is a Small Business, do you anticipate subcontracting primarily to other Small Businesses or utilizing specialty


           Large Business manufacturers for specialized hardware?


E. Bonding Capacity


  1. Single Project Bonding Capacity:________________
  2. Aggregate Bonding Capacity:________________

F. Project Interest


  • If a formal solicitation (Request for Proposal) is advertised for this requirement using a Best Value Tradeoff (BVTO) source selection process, does your firm anticipate submitting a proposal?
  • ☐  Yes
  • ☐  No

4. SUBMISSION INSTRUCTIONS


Responses to this Sources Sought notice must be submitted electronically via email to the Contract Specialist and Contracting Officer identified below.



Please limit capability statements to no more than seven (7) pages (excluding standard certifications and cover pages). All responses must be transmitted in PDF format.



Similar Contracts

Same NAICS industry code

NAICS: 333923
New
Federal
Low Level Cranes- CSO
Solicitation # W911KF25SC002A0018
The Army Contracting Command-Anniston Army Depot is seeking innovative commercial solutions through a Commercial Solutions Opening Area of Interest to replace seven aging low-level cranes in Building 400 in Anniston, Alabama. The scope of work includes the design, fabrication, delivery, installation, and testing of four 20-ton cranes (including one cab-operated unit) and four 10-ton cranes, with each of the seven main cranes paired with a 5-ton auxiliary hoist. All equipment must be designed to CMAA Class D for heavy service and utilize top-running bridges on existing support structures. The contractor is responsible for providing all labor and equipment for comprehensive no-load and full-load tests in the presence of government personnel, as well as providing operator and maintenance training. The government will conduct a merit-based evaluation focusing on technical and innovative merit, delivery and lifecycle sustainment, and price reasonableness. Key technical requirements include compliance with ISO, ANSI, UL, and CE certifications, as well as the ability to integrate into existing physical infrastructure. This solicitation is not a set-aside. Interested parties must be registered in the System for Award Maintenance and submit written solutions via email to the contracting officer and contract specialist by November 30, 2026. Final selection is contingent upon the availability of appropriate funds.
W6QK Acc Anad

POSTED

about 18 hours ago

DEADLINE

in 10 days
View Details
NAICS: 333923
New
Federal
SOLICITATION: N6449827Q0011 - Lifting Clamps (Crosby Brand Name or Equal) | 100% SB Set-Aside
Solicitation # N6449827Q0011
Solicitation N6449827Q0011 is a competitive procurement for 12 IPPE10HNM Lifting Clamps (Crosby brand name or equal) to support the Naval Foundry and Propeller Center (NFPC) and the Columbia-class submarine program. This is a Small Business Set Aside - Total procurement conducted as a Firm-Fixed Price agreement under FAR Part 12 and FAR Part 13. The required clamps must have a minimum working load limit of 12 metric tons per pair, an adjustable jaw opening from 0 to 16.5 inches, and a maximum weight of 80 lbs per clamp. They must be suitable for temperatures between -4F and +158F, comply with ASME B30.20 or EN 13155 safety standards, and be factory proof-tested to 200% of their rated capacity. The contract is managed by the Naval Surface Warfare Center Philadelphia Division, with delivery required within 30 calendar days of award on a Contractor Destination FOB basis. Award will be based on a sequential evaluation of price and technical acceptability, with the lowest-priced technically acceptable and responsible offeror selected. All shipments must adhere to MIL-STD-130 and MIL-STD-129 marking standards and be processed through the Wide Area WorkFlow (WAWF) system for payment. Quotations must be submitted via the Procurement Integrated Enterprise Environment (PIEE) Solicitation Module by the specified deadline.
Nswc Philadelphia Division

POSTED

2 days ago

DEADLINE

in 14 days
View Details
NAICS: 333923
New
5-TON CHAIN HOIST — 3020017133763 — N0010427QBC70
Solicitation # N0010427QBC70
This fixed-price solicitation, issued by NAVSUP Weapon Systems Support MECH, is for the procurement of 5-Ton Chain Hoists under NSN 3020-01-713-3763. The requirement is set aside for SBA. The scope of work includes the delivery of the hardware and a Technical Data Package (TDP) as defined in MIL-T-31000. A key deliverable is the submission of a Certificate of Compliance per DI-MISC-81356 at the time of material delivery to NAVSUP-WSS code N9433. Delivery is required within 120 days, with terms specified as FOB Destination Other and transportation costs prepaid to the destination. Award will be granted to the responsible offeror providing the lowest priced, technically acceptable offer. Technical acceptability is based on compliance with Section L instructions and adherence to all solicitation terms. The government will utilize the Supplier Performance Risk System (SPRS) to evaluate item, price, and supplier risk. Inspection and acceptance are conducted at the origin (contractor's plant), and the contractor must maintain an inspection system acceptable to the government. Packaging must adhere to MIL-STD-2073, with specific cleanliness and preservation requirements invoking MIL-PRF-23199, MIL-STD-767, or MIL-STD-2041 where applicable. All shipments must be marked in accordance with MIL-STD-129, and DLR items require specific blue and yellow labeling.
Navsup Weapon Systems Support Mech

POSTED

2 days ago

DEADLINE

in 29 days
View Details

More opportunities from Department Of Defense → W072 Endist Nashville

Same awarding agency

NAICS: 335313
Federal
Supply and Deliver DC and AC Preferred Systems for USACE-LRN
Solicitation # W912P527QA001
The Nashville District of the U.S. Army Corps of Engineers is soliciting quotes for a Commercial Firm Fixed-Price contract to fabricate, supply, and deliver DC and AC preferred systems for the J. Percy Priest Dam and Powerhouse. Under NAICS code 335313, the project requires the delivery of a complete system, including specific components such as a UL 1008-listed 800A Manual Transfer Switch, safety support equipment, and interior signage. All items must be delivered to the J. Percy Priest Powerhouse in Nashville, Tennessee, on or before June 10, 2027, with a two-week notice required prior to delivery. The government will award the contract to the responsive and responsible offeror who provides the lowest price while achieving a Successful Technical Conformance rating. Offerors must be registered in the System for Award Management and the Procurement Integrated Enterprise Environment, as quotes must be submitted exclusively through the PIEE Solicitation Module in PDF format. The current response deadline is November 30, 2026, by 1:00 PM CST. Due to the presence of Controlled Unclassified Information, including supply layouts and site photos, approved U.S. citizens and foreign nationals must submit specific security access forms to the Nashville District points of contact to view restricted documents. Additionally, contractors must maintain CMMC Level 1 certification and comply with strict DoD item unique identification and marking standards per MIL-STD-130 and MIL-STD-129.
Switchgear and Switchboard Apparatus Manufacturing

POSTED

8 days ago

DEADLINE

in 11 days
View Details

Get AI-powered intelligence on this solicitation and the ones like it

Every solicitation package arrives shredded into a compliance breakdown and matched to your past performance, with incumbent history and alerts on amendments and award.

Miguel
Hillary
Keith Deutsch
Christine

Join 900+ contractors already using CLEATUS