X-RAY FLUORESCENCE ANALYZER
Contract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
AI Contract Overview
This solicitation, issued by the Missouri Department of Health and Senior Services, is a Single Feasible Source procurement for X-ray Fluorescence (XRF) analyzers and related services. SciAps Inc. is identified as the sole manufacturer of the X-500 and the only company capable of servicing the XRF for lead paint analysis. The required X-550 Pb model is the only portable analyzer that does not require a radioactive source and has received a HUD Performance Characteristics Sheet (PCS) for action levels of 1.0 mg/cm2, 0.7 mg/cm2, and 0.5 mg/cm2. The equipment must feature a maximum test time between 2-6 seconds and must not have substrate corrections or inconclusive ranges. The contract has a target minimum release amount of 70,525.00 USD and runs from the effective date through August 31, 2027, with two one-year renewal options. Terms include immediate payment and FOB shipping. To be considered for the award, suppliers must be registered in MissouriBUYS and submit all necessary business compliance exhibits by the deadline of November 24, 2026. There is no set-aside status for this solicitation.
General Info
Place of Performance
Set-Aside
Documents
2Read all 2 documents
Due in 6 daysEvery page of every file, in your free workspace.
Read the documentsAI Contract Breakdown
Uniform Contract FormatSign up to view the full breakdown with detailed analysis of each section.
View Full BreakdownEverything you need to bid on this one
Open the full contract in your free workspace.
- 2 solicitation documentsRead every page
- AI contract breakdown13 sections, Uniform Contract Format
- Buyer contactEmail
Ask CLEATUS
I've read this contract. Ask me anything.
Timeline
Solicitation
Submission deadline
Response Deadline
Organization & Contact Information
Full Description
The X-550 Pb is the only portable XRF analyzer manufactured that has received a HUD Performance Characteristics Sheet (PCS) at action levels of 1.0 mg/cm2, 0.7 mg/cm2 and 0.5 mg/cm2 and that does NOT require a radioactive source. The PCS also states the SciAps X-550 Pb does not have any inconclusive ranges nor any substrate corrections. All tests require a maximum test time between 2-6 seconds depending on the lead concentration. Because there is no radioactive isotope, the test time.
SciAps is the only company able to service this XRF for lead paint analysis.
Similar Contracts
Same NAICS industry code
More opportunities from Missouri → DHSS HEALTH AND SENIOR SERVICES
Same awarding agency
Get AI-powered intelligence on this solicitation and the ones like it
Every solicitation package arrives shredded into a compliance breakdown and matched to your past performance, with incumbent history and alerts on amendments and award.
Join 900+ contractors already using CLEATUS