Y -- Safe Storage Enclosure (SSE) Roof Construction - 105-D Reactor

Closed
0105D-MR-G0003Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

General Info

Agency

N/A

NAICS

N/A

Place of Performance

105-D Reactor100 Area Hanford Site, Washington State 99352

Set-Aside

SBA

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseClosed
Posted

Presolicitation

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyN/A
Contacts1 person available
OfficeN/A
Organization / Agency
N/A
Office AddressN/A
Contacts
Alane J. DulskiAdministration

Full Description

Show more
The construction of the roof over the SSE (with a design life of up to 75 years) will occur during the final stages of the project to construct the SSE. Most radiological contamination will have been fixed or removed in underlying areas where the roof is to be constructed. A new roof will be designed and constructed over the SSE that will conceptually consist of structual steel columns, beams, girts and purlins with pre-formed standing seam steel roofing. Open areas between the roof and the top of the reactor shield wall (gable ends and eaves) will be closed with similar sheet steel roofing material. The roof structure will be anchored to the top of the reactor shield walls. All remaining SSE penetrations will be sealed. The final SSE roof structure design and calculations will be part of the subcontract for engineering, design, and construction of the SSE. This subcontract will be set-aside for award to small business firms only. The estimated subcontract value is between $1.8 and $2.5 million. The subcontract performance period (award through design and completion of SSE roof construction) will be approximately 18 months. For more information, please contact Earle Marvin, Senior Subcontracts Administrator,contact@example.gov

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS