Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Pre-Solicitation opportunity was posted on September 8, 2006. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Y -- Southern MD P&DC HVAC Upgrade solicitation 512582-06-A-0012

Closed
512582-06-A-0012Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 236210
New
Federal
Building 215 Clean Room HEPA Filter Replacement
Solicitation # RFI-195000-26-00181
The National Institute of Standards and Technology is conducting market research through a Request for Information for the Building 215 Advanced Measurement Laboratory cleanroom repair and HEPA filter replacement project in Gaithersburg, Maryland. This initiative follows a previous solicitation that failed to produce an acceptable offer, prompting NIST to reassess its acquisition strategy and seek industry feedback on constructability, cost, and schedule feasibility. The project scope involves the modernization of an 1,800 square meter facility, including the replacement of approximately 1,200 HEPA filters, 70 VAV terminal units, and 54 airflow monitoring devices, as well as the installation of 32 exhaust air control valves and associated ductwork repairs, testing, and recertification. A critical component of the project is the proposed phasing plan, which aims to minimize research disruptions by utilizing 19 construction phases, including 18 critical cleanroom outage phases. Each critical outage is currently envisioned as a nine-day window starting Friday evening and requiring 24/7 operations to achieve ready-for-re-occupancy by the following Monday morning. NIST is specifically requesting rough-order-of-magnitude cost estimates and industry input on whether this aggressive outage schedule is realistic or if it creates prohibitive risks and costs. Responses, including company experience and recommendations for improving competition and project execution, are due by October 14, 2026.
Department Of Commerce Nist

POSTED

2 days ago

DEADLINE

in 12 days
NAICS: 236210
New
Federal
Sources Sought - POST TEST LITHIUM BATTERY STORAGE
Solicitation # N00167-27-RFPREQ-CD-102-0002
The Naval Sea Systems Command Naval Surface Warfare Center Carderock Division is conducting a sources sought effort for the construction of a Post-Test Lithium Battery Storage Facility in West Bethesda, Maryland. This project, classified under NAICS code 236210 for Industrial Building Construction, involves the creation of a storage area featuring a non-flammable single-pitch sloped roof, a perimeter fence with a gate, 3-hour rated firewalls, and concrete walls for large battery storage. Additional requirements include low-voltage outlets, pole-mounted LED flood lighting, and a dedicated forklift access road. The effort must be completed within 210 days of the award and adhere to Unified Facilities Guide Specifications and other stringent technical criteria. This notice is not a request for proposal, and no award will be made directly from this notice. Interested small and large businesses must submit a capability statement and a Rough Order of Magnitude by 1700 EST on 18 November 2026 to Heather Valiga. The government will use these responses to determine the future acquisition strategy. Because the project is located on a secure military installation, all personnel must obtain proper clearances and credentials. Key deliverables include an Activity Hazard Analysis and a detailed schedule due within five days of the pre-construction meeting, as well as a personnel list provided seven days before the start date.
Nswc Carderock

POSTED

2 days ago

DEADLINE

in 28 days

General Info

Agency

N/A

NAICS

236210 - Industrial Building Construction

Place of Performance

9201 Edgeworth DrCapital Heights MD 20790-9998

Set-Aside

NONE

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

2 updates
PhaseClosed
Posted

Presolicitation

Notice updated

The notice description changed.

Notice updated

The notice description changed.

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyN/A
Contacts2 people available
OfficeN/A
Organization / Agency
N/A
Office AddressN/A

Full Description

Show more
Amendment 2 was issued 9/8/2006 changing period of performance, revising section 01115 phasing work, and including environmental reports for this project. The United States Postal Service intends to award a fixed price construction contract for HVAC renovation of the Southern MD Processing and Distribution Facility (P&DC) in Capital Heights MD. The Scope of Work includes, but is not limited to, providing all labor, equipment, and materials to upgrade the HVAC system in a phased schedule at the Southern MD P&DC per the attached drawings and specifications. This work includes new boilers, air handlers, VAV boxes, roof top package DX units, distribution, and bacnet compliant DDC controls. The scope also includes associated electrical systems work and incidental structural and architectural work with the total construction cost ranging from $9.8M to $10.8M. The contract will be accomplished in five phases with total period of performance of 540 days. A detailed scope of work for this project is included in the solicitation documents. This request for proposal is being issued only to prequalified contractors. Previously, the following the firms were prequalified and are the ONLY ones invited to submit proposals for this solicitation: The Postal Service has qualified in response to solicitation 512582-05-A-0003 the following five construction firms for a fixed price construction contract: James N Gray Company,10 Quality Street,Lexington, KY 40507-1450,Forrest Miller, Program Manager,Tel: 859-281-5000,Fax: 859-252-5300,Email: FMILLER@jngray.com,; The Walsh Group,929 West Adams,Chicago, Illinois 60607,Ric Krause, Vice President,Tel: 312-563-5400,Fax: 312-563-5420, Email: rkrause@walshgroup.com, The Whiting-Turner Contracting Company, 300 East Joppa Road,Baltimore, Maryland 21286,Ron Eisenberg, Division Vice President,Tel: 410-821-1100,Fax: 410-337-5770,Email: ron.eisenberg@whiting-turner.com; Turner Construction Company,,3865 Wilson Blvd.,Arlington, Virginia 22203,Christian E. Jahrling, Vice President and General Manager,Tel: 703-841-5200,Fax: 703-841-5228,Email: cjahrling@tcco.com, bpasquariello@tcco.com; Walbridge Aldinger Company, 613 Abbott Street,Detroit, Michigan 48226,Mr. Ronald Hausmann, President-HCS Group,Tel: 313-442-1350,Fax: 313-234-0550,Email: rhausmann@walbridge.com. The USPS will select the offer that provides the Best Value to the Postal Service, taking into consideration technical and cost related factors. While the above listed five firms have already been furnished a Solicitation Package on CD, others, i.e. subcontractors, material, equipment suppliers and other interested parties can purchase copies of the Solicitation. It is available on a Compact Disks (CDs contain complete solicitation with plans provided in plot file, drawing file and pdf format) or full set of plans and specs ?Hard Copy? with CDs may be purchased. Copies of the solicitation, specification or drawings may be purchased from LDI Reproprinting Center. Orders can be e-mailed to usps@ldireproprinting.com. Order by phone Toll Free 1-877-913-5277. Order by fax 770-491-7375. All technical questions concerning this Solicitation must be sent through any one of the five pre-qualified firms. We will only accept questions from the pre-qualified contractors via e-mail and in ?Word? format and they should be directed to Mr. Bill Powell at bill.powell@usps.gov. Proposals are due by 3:00 PM EST, September 21, 2006 and should be mailed, using one of the services offered by the Postal Service, to Mr. Powell, Supply Management Facilities Portfolio, 4301 Wilson Blvd., Suite 300, Arlington, VA 22203-1840. The USPS encourages the participation of small, minority, and women owned business subcontracts for this project.

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS