Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, September 30 at 2:00 PM EDT

Register Free →

Z1AA--TV DIGITAL CONVERSION

Active
36C24526Q0850Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

General Info

Agency

Department Of Veterans Affairs → 245-NETWORK Contract Office 5 (36C245)View Agency

NAICS

561210 - Facilities Support ServicesView NAICS

Place of Performance

Department of Veterans Affairs Washington DC VA Medical Center, MD

Set-Aside

NONE

Documents

(1)

36C24526Q0850.docx

DOCX

AI Contract Breakdown

Uniform Contract Format

What is UCF?

Uniform Contract Format (UCF) uses AI to break down any contract into standardized sections—scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseSources Sought
Posted

Sources Sought

Response Deadline

Submission deadline

Response Deadline

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 245-NETWORK Contract Office 5 (36C245)
Contacts1 person available
OfficeLINTHICUM, MD, 21090, USA
Organization / Agency
Department Of Veterans Affairs → 245-NETWORK Contract Office 5 (36C245)
View Agency Profile
Office AddressLINTHICUM, MD, 21090, USA
Contacts
Jameel GordonContracting Officer

Full Description

Show more
SOURCES SOUGHT ANNOUNCEMENT: This is a SOURCES SOUGHT ANNOUNCEMENT ONLY , it is neither a solicitation announcement nor a request for proposals or quotes and does not obligate the Government to award a contract. Requests for a solicitation will not receive a response. Responses to this sources-sought must be in writing. The purpose of this SOURCES SOUGHT ANNOUNCEMENT is for market research to make appropriate acquisition decisions and to gain knowledge of potential sources capable of providing the services described below.
Documentation on technical expertise must be presented in sufficient detail for the Government to determine that your company possesses the necessary functional area expertise and experience to compete for this acquisition. Responses to this notice shall include the following:
Company name:
(b) Address:
(c) Point of Contact:
(d) Phone, Fax (if applicable), and Email:
(e) SAM Unique Entity ID:
(f) Cage Code:
(g) Tax ID Number:
(h) Type of business, SDVOSB; VOSB, WOSB, small, large, etc., as appropriate:
Must provide a Capability Statement that addresses the organization s qualifications and ability to perform as a contractor for the statement of work described below. Failure to provide sufficient information may result in the Government s inability to determine whether the respondent is capable. GENERAL STATEMENTS OF CAPABILITY ARE NOT ACCEPTABLE.
Federal Supply Schedule Contracting # if applicable
General Pricing
All interested parties should submit information by email only to jameel.gordon@va.gov. All emails must have as the subject line, Sources Sought Notice No. 36C24526Q0850 Analog-to-Digital Signal Conversion. All submissions must be received no later than 3:00 PM (EST) on September 24, 2026.



Statement of Work
Title: Analog-to-Digital Signal Conversion Location: Washington DC VA Medical Center Address: 50 Irving Street NW, Washington, DC 20422
PURPOSE This Statement of Work defines the requirements to convert the patient and public television distribution system at the Washington DC VA Medical Center from analog to digital signal delivery, and to replace or supplement the display equipment that cannot receive a digital signal. The work covers headend and RF distribution reconfiguration, replacement of legacy patient-room displays that lack a digital tuner, installation of digital set-top converters where existing displays remain serviceable, extension of distribution service to Fisher House, network cabling to support the replacement displays, and full system programming, verification, and closeout documentation. The Contractor shall provide all labor, supervision, tools, test instrumentation, equipment, materials, transportation, consumables, documentation, and incidentals necessary to perform the work. BACKGROUND DCVAMC distributes television service to patient rooms, waiting areas, lounges, conference rooms, staff areas, and the Community Living Center over a campus RF cable plant. The plant and a substantial share of the connected displays predate the digital transition. As the signal is converted to digital delivery, displays without a digital tuner or without a tuner capable of the delivered modulation lose service. The VA Washington DC 2025 + 2026 TV Locations inventory (Attachment A) documents 321 television location rows across the Main Hospital, the Community Living Center, and associated areas. Within that inventory: 37 entries are legacy P15X-series patient-room displays flagged for digital compatibility concern 20 in the Main Hospital 4E area and 17 in the CLC Dialysis unit. One of the 4E entries is recorded as "4E North (?) P15X TVs," a plural entry of indeterminate count. 4 entries are GW-brand units (models K948 and PIT-1702) in the CLC rooms 2H-101(1), 2H-138(2), 2K-138(1), and 2K-154(1). The 2K-154(1) entry is annotated "NOT REPLACED." A large population of wall-mounted displays in waiting rooms, lounges, conference rooms, and staff areas requires a digital set-top converter rather than replacement, because the display itself remains serviceable. The inventory records approximately 19 locations as having no television and several as under construction or condemned. These are excluded from scope unless the Government directs otherwise in writing. Fisher House is not currently served by the campus distribution and requires a cable extension and receiver installation to bring it onto the converted system. The replacement patient-room displays specified in Section 4.1 are network-connected computing devices, not conventional televisions. Section 6 states the information technology and information security requirements that follow from that fact. Those requirements are not optional and are not severable from the installation work. SCOPE OF WORK The Contractor shall: Verify the installed television population against Attachment A and field-test the legacy P15X-series displays to confirm which units can and cannot receive the delivered digital signal (CLIN 0001). Reconfigure the headend and RF distribution plant for digital delivery, install distribution amplification, and repair signal pathway deficiencies identified during verification (CLIN 0002). Replace the 4 GW-brand patient-room displays and their mounting arms (CLIN 0003). Replace the P15X-series patient-room displays with interactive arm-mounted patient displays meeting the salient characteristics in Section 4.1, including mounting arms (CLIN 0004). Install digital set-top converters on serviceable wall-mounted displays in non-patient areas (CLIN 0005). Extend distribution service to Fisher House and install and test the Fisher House receivers (CLIN 0006). Install network cabling to each room receiving an Ethernet-capable replacement display (CLIN 0007). Program the channel map, verify signal quality end to end, orient facility staff, and deliver closeout documentation including an as-built channel map and a complete asset list (CLIN 0008). Complete all information technology and information security requirements in Section 6 before any network-connected device is placed into service. Coordinate all work with the COR, FMS, Engineering, OIT, the Information System Security Officer, IP&C, Safety, Nursing, and affected clinical services. EQUIPMENT The Government will accept any product meeting the characteristics stated below. Quoters shall submit manufacturer specification sheets demonstrating conformance for every proposed item. 4.1 Interactive Arm-Mounted Patient Display (38 units) CHARACTERISTIC MINIMUM REQUIREMENT Screen size 15.6 inches diagonal or greater Resolution 1920 × 1080 minimum Tuner Integrated ATSC and clear-QAM tuner (Air VHF/UHF, CATV, IRC, HRC); must acquire the modulation delivered by the DCVAMC headend without an external converter Content protection Pro:Idiom or equivalent hospitality content protection compatible with the DCVAMC distribution Mounting Compatible with a patient-TV articulating arm; VESA 75 × 75 mm rear mount acceptable Power Low-voltage Power over Coax or Power over Ethernet. Line-voltage-only units are not acceptable in patient rooms. Connectivity Ethernet (RJ45) and 75-ohm RF input, both required. Wireless is not an acceptable substitute for a wired Ethernet path. Camera and microphone NOT PERMITTED. Units furnished shall have no integrated camera and no integrated microphone. This is a patient privacy requirement and is not waivable. Operating system If the unit runs a general-purpose operating system, that OS version shall be actively supported by its publisher with security updates for a minimum of 36 months from the date of acceptance. See Section 6.2. Infection control Bleach-cleanable enclosure; antimicrobial plastics; sealed glass front Regulatory UL 60065 Annex Q, UL 62368-1 Annex DVB, or successor healthcare low-voltage listing; FCC Title 15 Part 47 Subpart B Accessibility Closed-captioning support; Section 508 conformance evidenced by a current VPAT Volume control Audio volume limiter, min/max volume limiter, and internal speaker disable Setup Password-protected setup menus; channel enable/disable and aliasing/remapping; bulk cloning of setup and channel map across the installed population Warranty Minimum 1 year parts and labor, manufacturer standard, passed through to the Government at no additional cost 4.2 Patient-TV Articulating Arm (42 units 38 replacement, 4 GW-brand) CHARACTERISTIC MINIMUM REQUIREMENT Reach 68 inches minimum from mounting point Cable management Internal, concealed, carrying coaxial AND CAT6 in the same arm Mounting Wall, headwall, or ceiling mount as required by the room condition; base pin sized to the existing mount where reuse is directed by the COR Load rating Rated for the furnished display weight with a documented safety margin Motion Articulating with adjustable friction; positionable by a seated patient without tools Finish Antimicrobial, bleach-cleanable, healthcare-appropriate finish Regulatory UL-listed 4.3 Clear-QAM Digital Set-Top Converter (38 units) CHARACTERISTIC MINIMUM REQUIREMENT Tuner Clear QAM, 64/256, ITU-T J.83 Annex B; ATSC compliant Bandwidth 54 1000 MHz input Decoding MPEG-2 and MPEG-4 / H.264 AVC Resolution Standard and high definition; 480p through 1080p output Outputs HDMI with HDCP, and composite video with L/R audio, to serve both modern and legacy displays Conditional access Provision for conditional access where the delivered signal requires it Remote control Full-function remote, learning-capable, one per unit; IR extender provision where the converter is concealed Guide On-screen channel guide and PSIP compliance Power External low-voltage supply, 100 240 VAC input Form factor Enclosure small enough to mount behind or adjacent to a wall-mounted display without obstructing the mount 4.4 RF Distribution Amplifier (5 units) and Passives CHARACTERISTIC MINIMUM REQUIREMENT Bandwidth 54 1000 MHz forward path Gain Sufficient to deliver the signal levels required in Section 5.8 at every outlet on the served leg Passives Splitters, taps, connectors, and terminators rated to 1000 MHz and compatible with the installed plant Powering Compatible with the existing rack power provisions
TASK DESCRIPTION 5.1 CLIN 0001 Site Verification, P15X Field Testing, and Pre-Installation Survey Before ordering any equipment, the Contractor shall verify the installed population against Attachment A and shall field-test the legacy P15X-series displays to establish which units can and cannot receive the delivered digital signal. Walk every location listed in Attachment A that is identified for replacement or conversion; confirm room number, display make and model, mount type, existing cable plant, and outlet condition. Field-test each P15X-series unit against the delivered signal and record the result per unit. The count of 38 replacement units is a planning figure derived from 37 inventory entries plus the indeterminate "4E North (?)" entry; the survey establishes the actual count. Confirm the 4 GW-brand units and confirm with the COR whether the unit annotated "NOT REPLACED" in the inventory is in or out of scope. Identify every location requiring a set-top converter and confirm the 38-unit planning figure. Record, per room receiving an Ethernet-capable display, whether a usable network drop already exists, and if not, the pathway, distance, and difficulty of installing one. Measure and record RF signal level and MER at representative outlets on each distribution leg. Identify any location where the room condition, mount, or cable plant prevents installation as scoped. Deliverable: Verified installation schedule per-room, listing action (replace, convert, no action), equipment required, network drop required yes/no, and any obstruction within 20 calendar days of NTP. No equipment shall be ordered and no installation shall begin until the COR accepts this deliverable in writing. 5.2 CLIN 0002 Headend and RF Distribution Conversion Reconfigure the headend rack for digital delivery, including modulation, channel plan, and output level configuration. Install RF distribution amplification at the points identified in CLIN 0001. Repair signal pathway deficiencies failed splitters, corroded connectors, unterminated legs, damaged coaxial runs identified during verification. Balance signal levels across all distribution legs. Label the rack, all amplifier locations, and all modified distribution points. Coordinate every service interruption with the COR a minimum of 5 business days in advance. Interruptions to Dialysis, patient care units, and the CLC require COR-approved scheduling. 5.3 CLIN 0003 GW-Brand Patient Room Display Replacement (4 Units) Replace the 4 GW-brand units identified in Attachment A with displays and arms meeting Sections 4.1 and 4.2. Remove and turn over the displaced units per Section 5.9. Program each replacement to the campus channel map and verify operation with the patient pillow speaker or nurse call interface where one is present. 5.4 CLIN 0004 P15X Replacement, Interactive Arm-Mounted Patient Displays (38 Units) Remove the existing P15X-series display and arm. Install the replacement arm per Section 4.2, mounting into sound structural backing. Where existing backing is inadequate, install backing and notify the COR before proceeding. Route coaxial and CAT6 through the arm to the display. Install and secure the replacement display. Configure the display: channel map, volume limits, internal speaker disable where directed, closed captioning, password-protected setup, and any Government-directed content restrictions. Complete all Section 6 information security steps for the unit before it is placed into service. Verify RF signal, network connectivity, audio, and patient-reachable arm motion from the bed position. Record the asset: room, serial number, MAC address, arm serial, install date, and technician. Work in Dialysis and occupied patient rooms shall be scheduled through the COR and the responsible nurse manager. No work shall displace a patient or interrupt a treatment. 5.5 CLIN 0005 Non-Patient Area Digital Set-Top Converter Installation (38 Units) Install a converter meeting Section 4.3 at each location identified in the CLIN 0001 deliverable. Mount the converter concealed where practical; install an IR extender where the remote cannot reach the unit. Perform a full channel scan and load the campus channel map. Pair and label the remote to the room. Provide one spare remote per 10 installed converters. Verify picture and audio on every configured channel. Provide a one-page room-specific operating instruction sheet at each location. 5.6 CLIN 0006 Fisher House Distribution Extension and Receiver Installation Install the cable extension bringing Fisher House onto the converted distribution, including pathway, penetrations, fire-stopping, grounding, and bonding. Seal and weatherproof all exterior penetrations. Restore all disturbed finishes. Install and test the Fisher House receivers. Verify signal level and picture quality at every Fisher House outlet. 5.7 CLIN 0007 Network (CAT6) Drop Installation, 38 Rooms Install one CAT6 plenum-rated drop per room identified in the CLIN 0001 deliverable as lacking a usable existing drop. Terminate at the room end and at the serving telecommunications room; install jacks, faceplates, and patch panel positions. Label both ends per the DCVAMC labeling convention. Coordinate the labeling scheme with OIT before installation. Certify every drop to CAT6 performance and deliver the certification test results. Fire-stop all penetrations of rated assemblies and restore all disturbed finishes. Where the CLIN 0001 survey establishes that a usable drop already exists, no drop shall be installed and the CLIN quantity shall be reduced accordingly by bilateral modification. 5.8 CLIN 0008 Programming, Verification, Staff Orientation, and Closeout Build and push the campus channel map to every installed display and converter. Verify, at every installed location, RF signal level and MER within the specification stated by the display or converter manufacturer, and record the measured values. Verify picture and audio on every channel at a representative sample of not less than 20% of installed locations, and at 100% of Dialysis and patient-room locations. Verify network connectivity and Section 6 compliance at 100% of network-connected units. Conduct staff orientation for Nursing, Environmental Management, and FMS covering basic operation, remote use, channel map, and first-line troubleshooting. Deliver the closeout package per Section 9. 5.9 Removal and Disposition of Displaced Equipment All displaced displays, arms, mounts, and converters remain Government property. The Contractor shall remove them from the work area the same day, deliver them to the location the COR designates, and provide a signed disposition list identifying each removed item by room, make, model, and serial number. The Contractor shall not dispose of, scrap, or retain any removed item without the COR s written direction. Where the COR directs disposal, the Contractor shall handle displaced equipment as regulated electronic waste and provide a certificate of recycling. APPLICATION STANDARDS ANSI/TIA-568 and ANSI/TIA-569 structured cabling and pathways ANSI/TIA-607 bonding and grounding for telecommunications NFPA 70 (National Electrical Code), including Article 800 for communications circuits NFPA 99 (Healthcare Facilities), NFPA 101 (Life Safety), NFPA 70E (Electrical Safety) SCTE recommended practices for RF distribution and signal level measurement ITU-T J.83 Annex B QAM modulation FCC Title 15 Part 47 Subpart B OSHA 29 CFR 1910 and 1926, including 1926 Subpart M (fall protection) and 1910.147 (LOTO) Section 508 of the Rehabilitation Act VA Directive and Handbook 6500 information security VA Directive 0710 personnel security and PIV credentialing VA Technical Reference Model The Joint Commission Environment of Care and Infection Control standards Manufacturer installation and configuration instructions Washington, DC codes, regulations, and licensing requirements Where requirements conflict, the Contractor shall notify the COR. The more stringent requirement applies unless the COR directs otherwise in writing. CONTRACTOR RESPONSIBILITIES Provide qualified, trained, properly supervised personnel, including technicians experienced in healthcare RF distribution and structured cabling. Maintain required licenses, certifications, clearances, and insurance. Provide a DC-licensed electrician for any line-voltage work. Provide calibrated test instrumentation signal level meter, QAM analyzer, and CAT6 certification tester with current calibration certificates. Protect patients, staff, visitors, Government property, and building systems. Work in occupied patient rooms shall be scheduled through the COR and the responsible nurse manager. Comply with DCVAMC sign-in at the Control Panel, Room GE-225, 202-745-8405. Present the contract, the Purchase Order number, and valid photo identification. Sign out when leaving the facility. Comply with all Medical Center access, escort, ICRA/PCRA, hot-work, fire-watch, and safety procedures. Prevent dust, debris, noise, and service interruption beyond what the approved schedule permits. Remove debris daily. Restore all disturbed finishes to pre-work condition or better. Comply with VA Directive 0710 credentialing and background investigation requirements for every person on site. Report immediately to the COR any condition that affects patient care, safety, or information security. PERIOD OF PERFORMANCE 120 calendar days from issuance of the Notice to Proceed. Recommended sequencing: PHASE ACTIVITY Days 1 20 Site verification, P15X field testing, survey (CLIN 0001). Section 6.1 determinations confirmed. Product submittals. Days 20 35 COR acceptance of the verified installation schedule. Equipment ordered. ISSO approval of network placement. Days 25 55 Headend and RF distribution conversion (CLIN 0002). Network drop installation begins (CLIN 0007). Days 45 95 Display replacement in patient rooms and Dialysis (CLINs 0003, 0004). Converter installation (CLIN 0005). Days 55 80 Fisher House extension and receiver installation (CLIN 0006). Days 95 115 Programming, verification, and staff orientation (CLIN 0008). Days 110 120 Punch list, disposition, and closeout package. All dates are stated relative to NTP. Equipment lead time is a known schedule risk; the Contractor shall identify lead times in the project schedule and shall notify the COR immediately if any lead time threatens the completion date.

Similar Contracts

Same NAICS industry code

NAICS: 561210
New
Federal
PKA - VIP Furniture Management
Solicitation # FA706026R0016
The Department of the Air Force, through the 11th Contracting Squadron, is seeking a small business vendor for a firm-fixed-price contract to provide VIP Furniture Management services at Joint Base Anacostia-Bolling. The contract spans a five-year period of performance from September 30, 2026, through September 29, 2031, consisting of a base year and four option years. The scope of work includes the management, warehousing, transportation, installation, and maintenance of government-furnished furnishings, appliances, and window treatments for special command positions and general or flag officers. Specific service requirements include furnishing management, moving services, and dry cleaning services, with workload estimates provided for service calls, repairs, and occupancy turnovers for government-owned quarters. This opportunity is a 100 percent small business set-aside under NAICS 561210. Award decisions will be based on a trade-off determination where past performance is the most important factor, followed by technical capability and price. Proposals are evaluated on the offeror's proposed approach to the Performance Work Statement and a maximum of three prime contractor references. Contract administration requires electronic invoicing via the Wide Area Workflow system and compliance with Service Contract Labor Standards and various Buy American and health and safety regulations. The contractor will be responsible for managing a detailed inventory of government-furnished property and adhering to strict quality control and security standards for base access and information handling.
FA7060 11TH Contracting Squadron Pk

POSTED

about 18 hours ago

DEADLINE

in 4 days
View Details
NAICS: 561210
New
SLED
Treatment For Boiler/Chiller Water Loop Systems
Solicitation # RFP 03-27
The County of Butte is soliciting proposals under RFP 03-27 for a qualified firm to provide chemical treatment and monitoring for open and closed loop boiler and chiller water systems at various county facilities in Oroville, California. The primary objective of this three-year contract is to reduce corrosion in piping systems, maintain operational efficiency, and extend equipment lifespan. The scope of work includes scheduled quarterly site visits for chemical analysis, dosing, and the inspection of chemical control and dispersing equipment, such as pumps and blow-down valves. Contractors must provide written test results at each visit and ensure all services comply with industry standards, environmental regulations, and applicable federal, state, and local laws. Proposals are due by October 6, 2026, and will be evaluated based on a point system weighing experience and qualifications (40 points), approach and methodology (30 points), and cost (30 points). The county emphasizes the importance of public sector experience, specifically with government municipalities and departments. Awarded contractors must adhere to strict insurance requirements, maintain safety standards regarding MSDS handling, and comply with ADA Title II web accessibility standards. Payments are processed monthly upon receipt of an approved invoice or claim form. The contract also includes specific clauses regarding the ownership of work products and the mandatory disclosure of any generative AI technology used in the performance of services.
County of Butte

POSTED

1 day ago

DEADLINE

in 18 days
View Details

More opportunities from Department Of Veterans Affairs → 245-NETWORK Contract Office 5 (36C245)

Same awarding agency

NAICS: 339112
New
Federal
Baltimore VAMC Washer/Decontamination
Solicitation # 36C24526Q0819
Solicitation 36C24526Q0819 is a firm-fixed price, unrestricted purchase order issued by the Department of Veterans Affairs for the procurement, delivery, and installation of one cart washer and two washer-disinfectors for the Sterile Processing Service at the Baltimore VA Medical Center in Maryland. The requirement specifies new equipment, accepting the Bemlied brand or an equal alternative. The contractor is responsible for providing all necessary accessories, consumables, transport, and extended installation, as well as conducting full system validation and providing equipment training. A minimum one-year warranty on all parts and labor is required, with the warranty period commencing upon the completion of validation testing. The award will be based on a comparative evaluation process to determine the most advantageous quote, considering both price and other factors. Submission requirements include a completed SF1449, a mandatory RFQ Line Item Worksheet in Excel format, and a manufacturer authorization letter for distributors. Delivery must be FOB Destination with a timeline of 12 months or less. The contractor must maintain specific insurance coverages, including 500,000 dollars per occurrence for general liability and 200,000 dollars per person for automobile liability. Final acceptance is contingent upon a joint inspection with the Contracting Officer's Representative to ensure all work is completed satisfactorily and any damaged or missing items are replaced at no cost to the government.
Surgical and Medical Instrument Manufacturing

POSTED

about 18 hours ago

DEADLINE

in 2 days
View Details
NAICS: 621610
New
Federal
DME AND RELATED SERVICES
Solicitation # 36C24527Q0788
Solicitation 36C24527Q0788 is a small business set-aside issued by the Department of Veterans Affairs, Network Contracting Office 5, to provide Durable Medical Equipment (DME) and related services for the Washington DC VAMC. The contractor is responsible for the comprehensive management of government-owned DME, including delivery, assembly, installation, repair, sanitization, and patient training. The base period of performance runs from October 1, 2026, through September 30, 2027, with a total potential duration not to exceed 5.5 years. Services are divided into four geographic zones, with specific CLINs for setup, installation, repairs, and emergency visits. All personnel must be direct employees of the contractor, as subcontracting is strictly prohibited. The contract requires strict adherence to Joint Commission standards and regulations from OSHA, FDA, DOT, and NFPA. Contractors must maintain a facility within a 30-mile radius of the DC VAMC featuring six designated operational areas, including inbound and outbound staging. Performance is monitored via a Quality Assurance Surveillance Plan (QASP), with key metrics requiring a 98 percent or greater success rate for delivery timeliness and purchase order adherence. Payment is made exclusively via Government Purchase Card, with invoices submitted electronically 30 days in arrears. Award will be based on the most advantageous value, where combined non-price factors—specifically technical capability and past performance—are significantly more important than price. Proposals must be submitted in three volumes (Technical Capability, Past Performance, and Pricing) to Contracting Officer Aria Melville. Following Amendment 0001, the final submission deadline has been extended to September 21, 2026, at 10:00 AM ET.
Home Health Care Services

POSTED

1 day ago

DEADLINE

in 2 days
View Details

Ready to Pursue This Opportunity?

Get AI-powered intelligence on this solicitation and the ones like it

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS